Hostname: page-component-848d4c4894-wzw2p Total loading time: 0 Render date: 2024-06-10T12:53:43.672Z Has data issue: false hasContentIssue false

The irritable occupant: recent developments in thermal comfort theory

Published online by Cambridge University Press:  19 August 2008

Nick Baker
Affiliation:
The Martin Centre for Architectural and Urban StudiesUniversity of CambridgeDepartment of Architecture6 Chaucer RoadCambridge CB2 2EBUnited Kingdom

Extract

This paper explores thermal comfort, following recent renewed interest in thermal comfort standards. It also reports on findings from the Thermal Comfort Task in the EU funded PASCOOL project which had an overall objective of promoting passive cooling and avoiding air conditioning. Finally, some tentative conclusions are developed together with their implications for architectural design.

Type
environment
Copyright
Copyright © Cambridge University Press 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Abercrombie, M., Hickman, C. J., Johnson, M. L. (1966). A Dictionary of Biology (fifth edition), Penguin Reference Books.Google Scholar
Baker, N., Standeven, M. (1996). ‘Thermal Comfort for Free-Running Buildings’, Energy and Buildings 23.CrossRefGoogle Scholar
Fanger, P. O. (1970). ‘Thermal Comfort: Analysis and Application in Environmental Engineering’, Danish Technical Press.Google Scholar
Fanger, P. O. (1993). ‘How to Apply Model Predicting Thermal Sensation and Discomfort in Practice’, Proc. BRE Conference Thermal Comfort, Past, Present and Future, 06.Google Scholar
Haigh, D. (1981). ‘User response in environmental control’, in Hawkes, D. and Owers, J. (eds), The Architecture of Energy, Construction Press.Google Scholar
Humphreys, M. (1978). ‘Outdoor Temperatures and Comfort Indoors’, Building Research Practice, 6 (2).Google Scholar
Humphreys, M. A., Nicol, J. F. (1996). ‘Conflicting Criteria for Thermal Sensation within the Fanger PMV Equation’, Proc. CIBSE ASHRAE Joint National Conference,Harrogate.Google Scholar
Leaman, A. (1993). ‘Designing for manageability’. Building Services, 03.Google Scholar
Leaman, A., Bordass, W. (1995). ‘Comfort and Complexity: Unmanageable Bedfellows?’ Workplace Comfort Forum, RIBA, London222303.Google Scholar
Nicol, J. F. (1990). ‘Passive Buildings Need Active Occupants’, Proc. World Renewable Energy Congress, Reading, UK.Google Scholar
Oseland, N. (1994). ‘Predicted and Reported Thermal Sensations in Climate Chambers, Offices and Homes’, BRE 1994 for publication in Energy and Buildings.Google Scholar
Oseland, N. A. ‘Productivity and the indoor environment’. In Rooley, R. (ed) Fourth Indoor Air Quality Conference, 06 1996, pp. 522, Cambridge: Mid Career College (ISBN 0 9524553 4 X).Google Scholar
Schiller, G. E. (1990). ‘A Comparison of Measured and Predicted Comfort in Office Buildings’, ASHRAE Trans 96 (1).Google Scholar
Sykes, J. M. (1989). ‘Sick Building Syndrome’, Building Services Engineering Research Technology 10 (1).CrossRefGoogle Scholar
Wilkins, J. P. (1995). ‘Adaptive Comfort Control for Conditioned Buildings’, Proc. CIBSE National Conference,Eastboume.Google Scholar