Skip to main content Accessibility help
×
Hostname: page-component-7479d7b7d-fwgfc Total loading time: 0 Render date: 2024-07-10T02:33:56.980Z Has data issue: false hasContentIssue false

22 - Pump Control System Case Study

from Part IV - Real-Time Software Design Case Studies for Embedded Systems

Published online by Cambridge University Press:  05 March 2016

Hassan Gomaa
Affiliation:
George Mason University, Virginia
Get access

Summary

This chapter describes a concise case study of a real-time embedded system, namely a Pump Control System. Of particular interest are several periodic activities necessitating the design of periodic tasks, in addition to examples of task design with temporal and control clustering. There is also a need for a state machine that is designed with three separate orthogonal regions in order to separate three different but interrelated control concerns. This is one of the shorter case studies in which the details of dynamic interaction modeling (covered in detail in other case studies) are left as an exercise for the reader. The end product of dynamic interaction modeling is an integrated communication diagram, which is used to transition into design modeling.

The problem description is given in Section 22.1. Section 22.2 describes the structural modeling, and Section 22.3 describes the use case model. Section 22.4 describes the object and class structuring. Section 22.5 describes the state machine model. Section 22.6 describes the integrated interaction model, which is an outcome of dynamic interaction modeling. Section 22.7 describes the design modeling, which consists of the distributed software design and distributed software deployment. This is followed by the design of the concurrent task architecture and detailed software design.

PROBLEM DESCRIPTION

A Pump Control System for a mineral mine has several pumps situated underground, which are used to pump out water that has collected at the bottom of the mine. Each pump has an engine, which is controlled automatically by the system. The system uses Boolean high- and low-level water sensors, in addition to an analog methane sensor, to monitor the environment inside the mineral mine. Detection of the high water level causes the system to pump water out of the mine until the low water level is detected. For safety reasons, the system must switch off the pump when the level of methane in the atmosphere exceeds a preset safety limit. Once the pump has been switched off, five minutes must elapse before it can be switched on again. For each pump, status information on the methane and water level sensors, as well as the pump engine, is sent to a central server. Human operators can view the status of the various pumps.

Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 2016

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

  • Pump Control System Case Study
  • Hassan Gomaa, George Mason University, Virginia
  • Book: Real-Time Software Design for Embedded Systems
  • Online publication: 05 March 2016
  • Chapter DOI: https://doi.org/10.1017/CBO9781139644532.023
Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

  • Pump Control System Case Study
  • Hassan Gomaa, George Mason University, Virginia
  • Book: Real-Time Software Design for Embedded Systems
  • Online publication: 05 March 2016
  • Chapter DOI: https://doi.org/10.1017/CBO9781139644532.023
Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

  • Pump Control System Case Study
  • Hassan Gomaa, George Mason University, Virginia
  • Book: Real-Time Software Design for Embedded Systems
  • Online publication: 05 March 2016
  • Chapter DOI: https://doi.org/10.1017/CBO9781139644532.023
Available formats
×