A New Model of X-Ray Position Sensitive Detector Developed in France

Published online by Cambridge University Press:  06 March 2019

Louis Castex
Affiliation:
Laboratoire de Mécanique-Physique, ERA CNRS n° 769, F-33405 Talence
Jean Lou Lebrun
Affiliation:
Département Matériaux, Ecole Nationals Supérieure d'Arts et Métiers, F-75640 Paris
Serge Bras
Affiliation:
Société Instruments SA, F-91160 Longjumeau
Get access

Extract

Since 1973 X-ray position sensitive detectors (P.S.D.) have been employed for stress analysis. The first models, based on the gas flow of Ar-CH4, were composed of a quartz fiber anode (20 um diameter), coated by a thin carbon layer. From 1975 the gas filling has become permanent. Hence the use of fiber P.S.D. (F-P.S.D.) was made easier; nevertheless, two important inconveniences remained. On the one hand, an intensive X-ray beam could destroy rapidly and locally the carbon film, which makes the detector malfunction; on the other hand, the pulse height analysis (P.H.A.), carried out in 1976, has proved to be ineffectual because of the design of the F-P.S.D. itself: its fiber impedance does not remain constant. Thus the appearnace, in 1979, of a new P.S.D. with a metallic wire (W-P.S.D.) presented a significant advantage (see Fig. 1). The anode—made of tungsten or molybdenum Gilded--can resist intensive X-ray beams perfectly. Hence the life of the detector is only limited by a possible ionization of the filling gas, which approximately corresponds to 1012 counts. A gas refilling--which will be provided in the standard equipment--allows us to use the detector again.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1980

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

(1) Borkowski, Kopp “new type of P.S.D. of ionizing using risetime measurement.” Review of Scientific Instruments, 1968, volume 39, n° 30, 1515-1522.Google Scholar
(2) Gabriel, Dupoxit “position sensitive proportional detector for X-ray cristallography.” Review of Scientific Instruments, 1972, volume 43, n° 11, 16001602.Google Scholar
(3) Allemand “dStecteur a localisation de particules.” Brevet n° 73-46051 du 21 decembre 1973.Google Scholar
(4) Groupement Francais pour l'Analyse des Contraintes par Diffractometrie de Rayons X.Google Scholar
- reunion du 15 novembre 1978, Grenoble, Miege.Google Scholar
- reunion du 16 mars 1979, Nancy, Bras.Google Scholar
(5) James, Cohen “geometrical problems with a P.S.D. employed on a di£fTactometer, including its use in the measurement of stress.” Journal of Applied Cristallography, 1979, 12, 339345.Google Scholar