Hostname: page-component-78c5997874-xbtfd Total loading time: 0 Render date: 2024-11-19T14:44:55.415Z Has data issue: false hasContentIssue false

A constant-speed penetrometer for high-resolution snow stratigraphy

Published online by Cambridge University Press:  20 January 2017

Martin Schneebeli
Affiliation:
Swiss Federal institute for Snow and Avalanche Research, CH-7260 Davos Dorf, Switzerland
Jerome B. Johnson
Affiliation:
Cold Regions Research and Engineering Laboratory, U.S. Army Corps of Engineers, P.O. Box 35170, Fort Wainwright, AK 99703-0170, U.S.A.
Rights & Permissions [Opens in a new window]

Abstract

A new constant-speed penetrometer for field and laboratory measurement has been developed. The initially independent work of SFISAR and CRREL has been brought together, and a portable field device is now in an advanced stage of testing. The new penetrometer has high rigidity and a high-resolution large dynamic range force sensor. It uses a much smaller sensing head (5 mm) than previous designs and has a constant-speed drive. With this construction, the penetration resistance of very fine layers and the influence of the bonding strength between snow grains can be more accurately determined than is possible with the rammsonde or Pandalp. Artificial foam layers as thin as 2 mm and thin layers in snow have been detected by the penetrometer. Thin snow layers detected from penetration-resistance profiles have been correlated to fine layering as determined from plane-section microphotographs of samples taken adjacent to the profile. The instrument’s measurements are highly repeatable and the lack of subjective decisions when operating the penetrometer makes the penetration resistance a quantitative measure of snow stratigraphy.

Type
Research Article
Copyright
Copyright © International Glaciological Society 1998

Introduction

The detection and classification of snow layers are most important in interpreting the snow cover. R. Haefeli (in Reference Bader, Haefeli, Bucher, Neher, Eckel and Thams.Bader and others, 1954) invented the first penetrometer to simplify the time-consuming task of digging snow profiles and to gain insight into spatial variability. The rammsonde (also called Swiss Rammsonde or Haefeli Sonde), was developed from penetrometers used in soil mechanics. The cone has a diameter of 40 mm with a 60 included angle. Haefeli recognized, however, that while the rammsonde can provide some characterization of the mechanical properties, it is unable to detect the thin layers often responsible for the formation of avalanches (R. Haefeli; in Reference Bader, Haefeli, Bucher, Neher, Eckel and Thams.Bader and others, 1954). While other penetrometers have been developed, the rammsonde is the only instrument designed to measure an index of the snow mechanical properties that has wide acceptance and use.

Reference BradleyBradley (1966) invented the snow resistograph. This instrument uses an upward working snow blade and records the resistance force values on paper. The angle of the blade is not specified, the surface area is 6.7 cm2. Reference st Lawrence and Bradley.St. Lawrence and Bradley (1973) compared the snow resistograph to the ram penetrometer. They found a good correlation between these instruments and could demonstrate a much better resolution of weak layers than was possible with the rammsonde. The resistograph has not been used widely, probably because of the complicated mechanical action and the limited maximal force range. Reference GublerGubler (1975) examined the rammsonde critically, and proposed several improvements, He demonstrated that there is a good correlation between the tensile strength of homogeneous artificial snow and rammsonde resistance. The problem of an insufficient vertical resolution to detect thin layers was not solved and the proposed improvements were not implemented in newer rammsondes. Reference Dowd and Brown.Dowd and Brown (1986) developed the digital resistograph. This instrument records the force every 0.5 cm, which is insufficient to detect thin layers that are often less than a few millimeters thick (Reference Föhn. and Armstrong.Föhn, 1993). Reference Brown and Birkeland.Brown and Birkeland (1990) described a more developed prototype, which could down-load data to a computer. Its force sensor and the electronics, however, lacked durability. No further development of the penetrometer has been undertaken. Reference Schaap and FöhnSchaap and Föhn (1987) tested a penetrometer developed from a commercial geotechnical instrument. The diameter of the cone was 11.3 mm with a 60° included angle. The depth resolution was 1 mm and it recorded on a chart recorder. The instrument showed a very fine resolution especially of the harder layers. Some of the layers could not be found by classical analysis by hand, making signal interpretation difficult. Additionally, the cone diameter is still too large to detect thin layers. No further development of this instrument has been undertaken. Reference AbeAbe (1991) combined multiple sensors into one instrument in an attempt to characterize the snowpack stratigraphy. The published measurements are not correlated to a reference. Reference VogelVogel (1995) used a very small diameter cone tip embedded in a thicker rod with a force transducer. No reliable measurements or comparisons have been conducted with this instrument. A commercial soil penetrometer with a dynamic impact (hammering) was adapted to the usual rammsonde (Reference Navarre, Taillefer, Gourves and Flavigny.Navarre and others, 1994). This instrument shows a better spatial resolution than the conventionally battering rammsonde, because the depth measurement and energy-impact calculation are automatically processed. The instrument’s ability to resolve thin layers and information about the snow microstructure is limited by the size of the cone.

These instruments all suffer from the same limitation in that the measured penetration resistance is not easily interpreted or correlated uniquely to other standard mechanical tests, either compressive, tension or shear. All penetrometers used in snow can therefore only be indicative of a normal mechanical property. Good correlations between penetration resistance and mechanical properties have been found for soils (Reference MeighMeigh, 1987). Reference FukueFukue (1979) showed that the penetration force of a small blade penetrometer was highly correlated to the unconfined compressive strength of snow. Reference Huang, Ma and Lee.Huang and others (1993) showed that micromechanical processes strongly affect penetration resistance in granular material. These findings support the proposition that thin-blade and small-diameter penetrometers can better detect the microstructural character of snow than can large-diameter cone penetrometers and, as a consequence, should be well correlated to the macro-scale mechanical properties.

During the past 3 years, Reference Johnson and Schneebeli.Johnson and Schneebeli (1997) worked independently to develop a penetrometer with high spatial resolution that could detect fine layering and micro-structural effects. Their independent efforts have been combined to further develop the instrument and to correlate the penetrometer resistance measurements to well-defined mechanical properties. The fundamental concept is that a continuously recording small-diameter or thin-blade penetrometer will make a more direct connection to the micromechanical properties than do large-diameter cone penetrometers. Hence, the measurement of thin layers and structural properties of snow should be improved. Several tests have been made using a prototype penetrometer to prove the concept.

Design Requirements and Experimental Evaluation of the Penetrometer

The snow penetrometer is designed to fulfill several requirements to minimize errors and interpretation ambiguities. The penetrometer should have a high rigidity and a constant penetration velocity. The measuring tip should have a small diameter (cone) or thickness (blade) and small length dimensions to allow detection of thin layers and the breaking of grain bonds rather than producing a primarily compressive failure. The depth of penetration should be at least 1.5 m to profile a normally deep snowpack. In addition, it should also be a field-portable device. High rigidity and constant velocity penetration minimize measurement inaccuracies that arise from the storage and release of energy during penetration and inertial forces caused by sudden penetration velocity changes. Constant-velocity penetration (1-40 mm s−1) avoids the rate-dependence associated with creep deformation. So far is no evidence of inertial forces in our records to date. Thin layers, either buried surface hoar, sun- or windcrusts, have typical vertical dimensions of between 3 and 10 mm. The measuring tip must therefore be of a similar or smaller vertical dimension than these layers.

The prototype penetrometer built at SFISAR is shown in Figure 1. A geared drive rod (diameter 18 mm) driven by a stepper motor is used to push a 5 mm diameter cone with a 90° included angle-sensing tip into the snow. The sensing tip is connected to a force transducer housed in a cone mounted on the end of the drive rod through a 3 mm rod. The motor and the force transducer are controlled by custom-made electronics and a computer. The penetration velocity was 30 mm s−1 and measurements were made every one-third of a millimeter to provide high spatial resolution, which corresponds to a data-acquisition rate of 90 Hz. The force transducer is a small-dimension piezorcsistive quartz sensor with a large measurement range (±500 N, resolution better than 0.02 N) Reference Johnson and Schneebeli.Johnson and Schneebeli, 1997)

Fig. 1. Prototype penetrometer with the penetrometer tip, the cone and force transducer shown in the inset. The tip shown here is not flared, in contrast to the tip used for our experiments.

Detection of Thin Layers from Penetrometer Resistance Profiles

Tests of the prototype penetrometer’s ability to detect thin layers were conducted both in a controlled laboratory setting and in the field.

In the laboratory, thin sheets of foam separated by an air layer (to simulate weak layers) were used to determine the minimum-size layer that could be detected by the penetrometer. An artificial material was used instead of snow so that layer thickness and resistance could be controlled. The layer was constructed by separating two Polyurethane foam sheets (2, 5 or 10 mm thick) from each other with an aluminum sheet of 1-10 mm thickness. The aluminum sheet contained a central hole which created an air layer between the foam sheets. Aluminum sheets, again containing through holes for the penetrometer, were placed on the top and bottom of the foam/aluminum stack and screwed together. The different thickness of the PU-foam layers causes a variable bending under load. The recognition of the thin layers is therefore more difficult, because the penetration resistance becomes smeared and does not drop to zero. A thicker layer of foam bends less when the penetration force is applied and the thinner layers of air can be discriminated. The result for 11 mm thick foam layers and a 2 mm thick air layer is shown in Figure 2. The penetration resistance does not reduce over a width of 2 mm. The minimal value is 0.013 MPa, and the mean value is around 0.05 MPa. The air layer can be seen completely (resistance 0.00 MPa) when the layer is more than 1.3 times thicker (air layer thicker than 7 mm) than the length of the measuring tip.

Fig. 2. Test measurements in Polyurethane foam. The thickness of the foam layers is 11 mm separated by a 2 mm air layer.

In the field, thin layers detected from penetrometer resistance profiles were compared to the stratigraphie layering of the snow as determined from microphotographs of surface sections of dimethylphtalate cast samples taken adjacent to the profile (Fig. 3). The tests were conducted on 16 January 1996 on the north-facing slope of Totalphorn (Switzerland) at 2460 m a.s.l. To prevent the lip from sliding on hard crusts, the measurements were made perpendicular to the slope. Three measurements were made with 200 mm spacing. Measurement variation was small and did not exceed an absolute deviation of 0.02 MPa, except at the lop hard crust at a depth of 20 mm (0.1 MPa). To investigate the structure of the thin layers, two samples were taken adjacent to the penetration tests. These samples were cast in dimethylphtalate and surface sections cut. The surface sections show the different layers clearly. Especially noticeable was the 20 mm thick weaker layer between the hard crusts near the top of the profile. Only a few, millimeter-thick, hard crusts were noticeable between 240 and 280 mm snow depth.

Fig. 3. Penetration resistance in a natural snowpack. The curve shows the averaged value of three measurements 20 cm apart. The thin hard and weak layers detected with the penetrometer are very visible in the sections. The surface sections show the harder and weaker layers. Black is ice.

Comparison of Hand Hardness and Penetration Resistance

The hardness of snow measured by hand was compared to the penetration resistance. The hand hardness was measured with a five-step scale (fist, four finger, one finger, pencil, knife). Hand hardness was chosen because thin layers of a few millimeters can be detected. The measurements were made at the Weissfluhjoch on a north-facing slope near a ridge on 12 April 1995. Two penetrometer measurements separated by a distance of 0.2 m were made, and the hand hardness was determined in between the penetrometer measurements. The density of the snow varied between 220 and 320 kg m−3. The results are shown in Figure 4. The penetration resistance shows a very high variability in the top 130 mm. The variability in hand hardness is much smaller. This top layer consisted of wind-blown snow with rounded grains. The layer from 130 to 400 mm consisted of small and solid faceted crystals. The penetration measurements were almost identical. The hand hardness shows a similar curve. However, the discontinuities shown in hand hardness are in fact slow changes in penetration resistance. The profile from 400 to 550 mm, consisting of rounded and slightly faceted crystals, shows a good correspondence to the penetration resistances, except for the jump at 400 mm. The hand hardness follows the values of penetration resistance up to 500 mm depth. The sudden decrease in penetration resistance below 500 mm and the increase between 550 and 600 mm was not detected by the hand hardness measurements. This layer again shows a high variability. Such layers with high variability seem to be very difficult to judge by hand hardness. The penetration resistance is not only a unique function of density but also of the bonding strength. The layer at the top of the profile (0-60 mm) has a similar density as the one at 420-480 mm of about 300 kg m −3. However, the top layer, consisting of rounded grains, has a much higher penetration resistance than the layer at 420-480 mm which consists of slightly faceted grains.

Fig. 4. Comparison of hand hardness (thick black line) (for scale see text) and two penetration measurements (thin black and thick grey line). The arrow marks the position where a slab could be released after the second jump with skis in a rutschblock test. The density of snow in kg m−3 is noted on the right side of the drawing.

Comparison of Tensile Strength and Penetration Resistance

The mechanical significance of penetration resistance measurements was evaluated by comparing them to the tensile strength (determined by using a centrifuge). Measurements of density, tensile strength and penetration resistance for natural and sieved snow were compared to each other. The samples used for tensile strength measurements were each 58 mm in diameter and 180 mm in length. A small notch was made in the middle of each sample to create a well-defined stress-concentration plane. The penetration resistance of the tensile samples was found by penetrating the snow surrounding the sample. Where possible, multiple penetration tests were taken around the tensile sample. The values for these tests were averaged and the standard deviation calculated.

Comparisons between bulk density using tensile strength and penetration resistance are shown in Figure 5. The relationship between density and tensile strength breaks down at densities greater than 450 kg m −3 and no well-defined relationship can be found (Fig. 5a). These are sieved samples made of strongly faceted and coarse (1-2 mm) snow crystals. A comparison of bulk density with penetration resistance (Fig. 5b) has less scatter than the corresponding density/tensile strength comparison. Penetration resistance increases linearly above 300 kg m−3. Little variation in penetration resistance and tensile strength with density could be found below this limit for snow tested in the laboratory. In general, tensile strength compared to penetration resistance shows a linear correlation (Fig. 6). The far-outlying values are for the same samples which show up as anomalous in the density-tensile strength relationship.

Fig. 5. Comparison between bulk density and tensile strength (a) and between bulk density and penetrometer resistance (b). The bars indicate the variation of the penetration tests surrounding the samples taken for tensile-strength testing. They also show the variability of the snow within about a 10 cm spacing.

Fig. 6. Tensile strength and penetrometer resistance. The bars indicate the variation of the penetration tests surrounding the samples taken for tensile strength.

Discussion

Our preliminary evaluation of the new penetrometer shows that it is capable of detecting thin hard and weak layers. For layers with a thickness greater than about 3 mm, the penetration resistance can be quantified so that it can be used to index the mechanical behavior of that layer. Our comparative tests between penetration resistance and tensile strength are not a good indicator of the penetrometer’s ability to provide mechanical-index information for snow. The comparative tests between penetration resistance and tensile strength and with density high-lighted two severe problems. First, it was very difficult to obtain homogeneous samples. The penetration resistance for the samples was an average of several measurements, whereas the tensile strength is determined for an isolated plane in the sample. This sample inhomogeneity (as detected by the penetrometer) is probably responsible for the large scatter. An effective comparison of penetrometer resistance with a mechanical property test should require that the samples be very homogeneous. Penetrometer-resistance variance through a snow sample can give a good assessment of the degree of homogeneity. The second difficulty is that the centrifuge tensile-strength device has not been adequately examined to determine its ability to provide repeatable and accurate results. In these cases, compressive tests may be better suited.

The penetrometer-design features of high rigidity, constant speed penetration and high spatial resolution allow it to delect thin layers and snow microstructure to a higher degree than either the rammsonde or Pandalp. Several improvements are planned for future penetrometer designs, including: (i) a smaller included angle of the measuring tip and a smaller-diameter cone tip to produce less compaction and (ii) a thin-blade tip to further reduce the tip thickness (1.5 mm). The optimal diameter of the conical measuring tip and under what conditions a blade or cone tip are desirable are not yet completely clear. A compromise between structural resolution and penetration force must be sought. The electronic noise should be reduced, because it is well above the detection limit of the force sensor. A difficult problem is the insertion and tightening of the measuring tip into the cone. Some of these problems have already been solved in a newer prototype.

The interpretation of penetrometer-resistance profiles in snow is at its start. Initial efforts indicate that it may be possible, through signal analysis, to use penetration resistance to index mean bond strength, obtain internal structural information and to some degree determine grain-size and spacing. These measurements combined with a visual assessment of snow-grain shape and morphology may provide a way forward to classifying snow more accurately and reducing the scatter of measurements on the physical properties of snow.

Acknowledgements

We thank J. Baselmans and H. Utelli for help in the field, and W. Caviezel and G. Klausegger for construction of the device.

References

Abe, O. 1991. [A prototype of fiber optic snow layer sonde.] Seppyo. J. Jpn. Soc. Snow Ice, 53(1), 1-9. [In Japanese with English summary.]CrossRefGoogle Scholar
Bader, H., Haefeli, R. Bucher, E. Neher, J. Eckel, O. and Thams., C. 1954. Snow and its metamorphism. SIPRE Transl. 14.Google Scholar
Bradley, C. C. 1966. The snow resistograph and slab avalanche investigations. International Association of Scientific Hydrology Publication 69 (Symposium at Davos 1965 — Scientific Aspects of Snow and Ice Avalanches), 251260.Google Scholar
Bradley, C. C. 1968. The resistograph and the compressive strength of snow. J. Glaciol., 7(51), 499506.Google Scholar
Brown, R. L. and Birkeland., K. W. 1990. A comparison of the digital resistograph with the ram penetrometer. In A Merging of Theory and Practice, International Snow Science Workshop, 9-13 October 1990, Bigfork, Montana. Proceedings, 1930.Google Scholar
Dowd, T. and Brown., R. L. 1986. A new instrument for determining strength profiles in snow cover. J. Glaciol., 32 (111), 299301.CrossRefGoogle Scholar
Föhn., P.M.B. 1993. Characteristics of weak snow layers or interfaces. In Armstrong., R., ed. ISSW ’92. A Merging of Theory and Practice. International Snow Science Workshop, 4-8 October 1992. Breckenridge, Colorado. Proceedings. Denver, CO, Avalanche Information Center, 160170.Google Scholar
Fukue, M. 1979. Mechanical performance of snow under loading. Tokyo, Tokai University Press.Google Scholar
Gubler, H.U. 1975. On the Rammsonde hardness equation. International Association of Hydrological Sciences Publication 114 (Symposium at Grindelwald 1974 — Snow Mechanics), 110121 Google Scholar
Huang, A.B., Ma, M.Y. and, Lee., J.S. 1993. A micromechanical study of penetration tests in granular material. Mech. Mater., 16 (1-2), 133139.CrossRefGoogle Scholar
Johnson, J. B. and Schneebeli., M. 1997. Snow strength penetrometer. United States Patent Application, 4 May 1997.Google Scholar
Meigh, A.C. 1987. Cone penetration testing: methods and interpretation. London, Butterworths. Construction Industry Research and Information Association.Google Scholar
Navarre, J.-P., Taillefer, A. Gourves, R. and Flavigny., E. 1994. Le “PANDA Neige”, Neiges et Avalanches. 66, 814.Google Scholar
Schaap, L.H.J. and Föhn, P.M.B. 1987. Cone penetration testing in snow. Can. Geotech. J., 24(3), 335341.CrossRefGoogle Scholar
st Lawrence, W. and Bradley., C. C. 1973. Comparison of the snow resistograph with the ram penetrometer. J. Glaciol., 12(65), 315321.CrossRefGoogle Scholar
Vogel, F., 1995. Schneeprofilmesssonde. German Patent Office Report. DE 195 03 017 A1.Google Scholar
Figure 0

Fig. 1. Prototype penetrometer with the penetrometer tip, the cone and force transducer shown in the inset. The tip shown here is not flared, in contrast to the tip used for our experiments.

Figure 1

Fig. 2. Test measurements in Polyurethane foam. The thickness of the foam layers is 11 mm separated by a 2 mm air layer.

Figure 2

Fig. 3. Penetration resistance in a natural snowpack. The curve shows the averaged value of three measurements 20 cm apart. The thin hard and weak layers detected with the penetrometer are very visible in the sections. The surface sections show the harder and weaker layers. Black is ice.

Figure 3

Fig. 4. Comparison of hand hardness (thick black line) (for scale see text) and two penetration measurements (thin black and thick grey line). The arrow marks the position where a slab could be released after the second jump with skis in a rutschblock test. The density of snow in kg m−3 is noted on the right side of the drawing.

Figure 4

Fig. 5. Comparison between bulk density and tensile strength (a) and between bulk density and penetrometer resistance (b). The bars indicate the variation of the penetration tests surrounding the samples taken for tensile-strength testing. They also show the variability of the snow within about a 10 cm spacing.

Figure 5

Fig. 6. Tensile strength and penetrometer resistance. The bars indicate the variation of the penetration tests surrounding the samples taken for tensile strength.