No CrossRef data available.
Article contents
Device closure of residual aortopulmonary window using Konar-MF occluder device: an attractive new option
Published online by Cambridge University Press: 22 May 2024
Abstract
We report a case of a residual aortopulmonary window where a new Konar-MF occluder device was used to close the defect. This device has a low profile and conforms to the anatomy of aortopulmonary window very nicely without unnecessary protrusion on either side. This report highlights the advantage of Konar-MF occluder device for closure of such defects.
- Type
- Brief Report
- Information
- Copyright
- © The Author(s), 2024. Published by Cambridge University Press
References
Bertolini, A, Dalmonte, P, Bava, G L, Moretti, R, Cervo, G, Marasini, M. Aortopulmonary septal defects. A review of the literature and report of ten cases. J Cardiovasc Surg 1994; 35: 207–213.Google ScholarPubMed
Gowda, D, Gajjar, T, Rao, JN, et al. Surgical management of aortopulmonary window: 24 years of experience and lessons learned. Interact Cardiovasc Thorac Surg 2017; 25: 302–309. DOI: 10.1093/icvts/ivx099.CrossRefGoogle ScholarPubMed
Stamato, T, Benson, LN, Smallhorn, JF, Freedom, RM. Transcatheter closure of an aortopulmonary window with a modified double umbrella occluder system. Cathet Cardiovasc Diagn 1995; 35: 165–167.CrossRefGoogle ScholarPubMed
Giordano, M, Butera, G. Percutaneous closure of an aortopulmonary window in a young adult patient: a case report of transcatheter closure with an occluder device. Eur Heart J Case Rep 2020; 4: 1–4.CrossRefGoogle Scholar
Odemis, E, Guvenc, O, Saygi, M, Demir, IH. Closure of aortopulmonary window using Nit-Occlud® PDA-R device in a 3-month-old infant. Pediatr Int 2016; 58: 754–756. DOI: 10.1111/ped.12943.CrossRefGoogle Scholar
Celebi, A, Yucel, IK, Balli, S, Kucuk, M. Two cases of transcatheter closure of central aortopulmonary shunts: one with an amplatzer duct occluder II and one with an amplatzer vascular plug I. Tex Heart Inst J 2016; 43: 241–245. DOI: 10.14503/THIJ-15-5080.CrossRefGoogle ScholarPubMed
Richens, T, Wilson, N. Amplatzer device closure of a residual aortopulmonary window. Catheter Cardiovasc Interv 2000; 50: 431–433.3.0.CO;2-K>CrossRefGoogle ScholarPubMed
Sadiq, M, Qureshi, A, Younas, M, Arshad, S, Hyder, SN. Percutaneous closure of ventricular septal defect using lifeTechTM Konar-MF VSD occluder: initial and short-term multi-institutional results. Cardiol Young 2022; 32: 755–761. DOI: 10.1017/S1047951121002985.CrossRefGoogle ScholarPubMed
Abdelrazek Ali, Y, Nour, A, Rashad, M, et al. Transcatheter closure of a large aortopulmonary window with the novel device multifunctional occluder (Konar) under TEE guidance (A case report). J Cardiol Cases 2022; 25: 370–372. DOI: 10.1016/j.jccase.2021.12.014.CrossRefGoogle ScholarPubMed
Saxena, A, Jay, R, Ravi, A, et al. Indian guidelines for indications and timing of intervention for common congenital heart diseases: revised and updated consensus statement of the working group on management of congenital heart diseases. Ann Pediatr Cardiol 2019; 12: 254–286. DOI: 10.4103/apc.APC_32_19.CrossRefGoogle Scholar