Hostname: page-component-77c89778f8-gvh9x Total loading time: 0 Render date: 2024-07-20T22:58:51.907Z Has data issue: false hasContentIssue false

Mesenteric near-infrared spectroscopy and risk of gastrointestinal complications in infants undergoing surgery for congenital heart disease*

Published online by Cambridge University Press:  07 September 2015

Ilias Iliopoulos*
Affiliation:
Paediatric Intensive Care Unit, Royal Brompton Hospital, London, United Kingdom Cardiac Intensive Care Unit, Cincinnati Children’s Hospital Medical Center, Cincinnati, Ohio, United States of America
Ricardo G. Branco
Affiliation:
Paediatric Intensive Care Unit, Royal Brompton Hospital, London, United Kingdom Paediatric Intensive Care Unit, Cambridge University Hospitals NHS Trust, Cambridge, United Kingdom
Nadine Brinkhuis
Affiliation:
Paediatric Intensive Care Unit, Royal Brompton Hospital, London, United Kingdom
Anke Furck
Affiliation:
Paediatric Intensive Care Unit, Royal Brompton Hospital, London, United Kingdom
Joan LaRovere
Affiliation:
Paediatric Intensive Care Unit, Royal Brompton Hospital, London, United Kingdom Division of Cardiovascular Critical Care, Children’s Hospital Boston, United States of America
David S. Cooper
Affiliation:
Cardiac Intensive Care Unit, Cincinnati Children’s Hospital Medical Center, Cincinnati, Ohio, United States of America
Nazima Pathan
Affiliation:
Paediatric Intensive Care Unit, Royal Brompton Hospital, London, United Kingdom Paediatric Intensive Care Unit, Cambridge University Hospitals NHS Trust, Cambridge, United Kingdom Department of Paediatrics, University of Cambridge, United Kingdom
*
Correspondence to: Dr I. Iliopoulos, MD, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Avenue, MLC 2003, Cincinnati, OH 45229-3026, United States of America. Tel: +1 513 803 9218; Fax: +1 513 636 3952; Email: ilias.iliopoulos@cchmc.org

Abstract

We hypothesised that lower mesenteric near-infrared spectroscopy values would be associated with a greater incidence of gastrointestinal complications in children weighing <10 kg who were recovering from cardiac surgery. We evaluated mesenteric near-infrared spectroscopy, central venous oxygen saturation, and arterial blood gases for 48 hours post-operatively. Enteral feeding intake, gastrointestinal complications, and markers of organ dysfunction were monitored for 7 days. A total of 50 children, with median age of 16.7 (3.2–31.6) weeks, were studied. On admission, the average mesenteric near-infrared spectroscopy value was 71±18%, and the systemic oxygen saturation was 93±7.5%. Lower admission mesenteric near-infrared spectroscopy correlated with longer time to establish enteral feeds (r=−0.58, p<0.01) and shorter duration of feeds at 7 days (r=0.48, p<0.01). Children with gastrointestinal complications had significantly lower admission mesenteric near-infrared spectroscopy (58±18% versus 73±17%, p=0.01) and higher mesenteric arteriovenous difference of oxygen at admission [39 (23–47) % versus 19 (4–27) %, p=0.02]. Based on multiple logistic regression, admission mesenteric near-infrared spectroscopy was independently associated with gastrointestinal complications (Odds ratio, 0.95; 95% confidence interval, 0.93–0.97; p=0.03). Admission mesenteric near-infrared spectroscopy showed an area under the receiver operating characteristic curve of 0.76 to identify children who developed gastrointestinal complications, with a suggested cut-off value of 72% (78% sensitivity, 68% specificity). In this pilot study, we conclude that admission mesenteric near-infrared spectroscopy is associated with gastrointestinal complications and enteral feeding tolerance in children after cardiac surgery.

Type
Original Articles
Copyright
© Cambridge University Press 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

*

This work was performed at the Paediatric Intensive Care Unit at the Royal Brompton Hospital, London, United Kingdom. The abstract of this study was presented at “Cardiology 2012: The 16th Annual Update on Pediatric and Congenital Cardiovascular Disease, Orlando, Florida, February 22–26, 2012”, World Journal for Pediatric and Congenital Heart Surgery, 2012.

I.I. and R.B. contributed equally to this study.

References

1. McElhinney, DB, Hedrick, HL, Bush, DM, et al. Necrotizing enterocolitis in neonates with congenital heart disease: risk factors and outcomes. Pediatrics 2000; 106: 10801087.Google Scholar
2. Weiss, SL, Gossett, JG, Kaushal, S, Wang, D, Backer, CL, Wald, EL. Comparison of gastrointestinal morbidity after Norwood and hybrid palliation for complex heart defects. Pediatr Cardiol 2011; 32: 391398.Google Scholar
3. Ostlie, DJ, Spilde, TL St, Peter, S, et al. Necrotizing enterocolitis in full-term infants. J Pediatr Surg 2003; 38: 10391042.Google Scholar
4. Carlo, WF, Kimball, TR, Michelfelder, EC, Border, WL. Persistent diastolic flow reversal in abdominal aortic Doppler-flow profiles is associated with an increased risk of necrotizing enterocolitis in term infants with congenital heart disease. Pediatrics 2007; 119: 330335.Google Scholar
5. McClave, SA, Chang, WK. Feeding the hypotensive patient: does enteral feeding precipitate or protect against ischemic bowel? Nutr Clin Pract 2003; 18: 279284.Google Scholar
6. Harrison, AM, Davis, S, Reid, JR, et al. Neonates with hypoplastic left heart syndrome have ultrasound evidence of abnormal superior mesenteric artery perfusion before and after modified Norwood procedure. Pediatr Crit Care Med 2005; 6: 445447.Google Scholar
7. del Castillo, SL, Moromisato, DY, Dorey, F, et al. Mesenteric blood flow velocities in the newborn with single-ventricle physiology: modified Blalock-Taussig shunt versus right ventricle-pulmonary artery conduit. Pediatr Crit Care Med 2006; 7: 132137.Google Scholar
8. Luce, WA, Schwartz, RM, Beauseau, W, et al. Necrotizing enterocolitis in neonates undergoing the hybrid approach to complex congenital heart disease. Pediatr Crit Care Med 2011; 12: 4651.Google Scholar
9. Hebra, A, Brown, MF, Hirschl, RB, et al. Mesenteric ischemia in hypoplastic left heart syndrome. J Pediatr Surg 1993; 28: 606611.Google Scholar
10. Booker, PD, Romer, H, Franks, R. Gut mucosal perfusion in neonates undergoing cardiopulmonary bypass. Br J Anaesth 1996; 77: 597602.Google Scholar
11. McQuillen, PS, Nishimoto, MS, Bottrell, CL, et al. Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: concordance and association with clinical variables. Pediatr Crit Care Med 2007; 8: 154160.Google Scholar
12. Tortoriello, TA, Stayer, SA, Mott, AR et al. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Paediatr Anaesth 2005; 15: 495503.CrossRefGoogle ScholarPubMed
13. Ranucci, M, Isgrò, G, De La Torre, T, et al. Near-infrared spectroscopy correlates with continuous superior vena cava oxygen saturation in pediatric cardiac surgery patients. Paediatr Anaesth 2008; 18: 11631169.CrossRefGoogle ScholarPubMed
14. Ricci, Z, Garisto, C, Favia, I, et al. Cerebral NIRS as a marker of superior vena cava oxygen saturation in neonates with congenital heart disease. Paediatr Anaesth 2010; 20: 10401045.Google Scholar
15. Ghanayem, NS, Wernovsky, G, Hoffman, GM. Near-infrared spectroscopy as a hemodynamic monitor in critical illness. Pediatr Crit Care Med 2011; 12 (Suppl 4): S27S32.Google Scholar
16. Ortmann, LA, Fontenot, EE, Seib, PM, Eble, BK, Brown, R, Bhutta, AT. Use of near-infrared spectroscopy for estimation of renal oxygenation in children with heart disease. Pediatr Cardiol 2011; 32: 748753.Google Scholar
17. Kaufman, J, Almodovar, MC, Zuk, J, Friesen, RH. Correlation of abdominal site near-infrared spectroscopy with gastric tonometry in infants following surgery for congenital heart disease. Pediatr Crit Care Med 2008; 9: 6268.Google Scholar
18. Slater, JP, Guarino, T, Stack, J, et al. Cerebral oxygen desaturation predicts cognitive decline and longer hospital stay after cardiac surgery. Ann Thorac Surg 2009; 87: 3644; discussion 44–45.Google Scholar
19. Kussman, BD, Wypij, D, Laussen, PC, et al. Relationship of intraoperative cerebral oxygen saturation to neurodevelopmental outcome and brain magnetic resonance imaging at 1 year of age in infants undergoing biventricular repair. Circulation 2010; 122: 245254.Google Scholar
20. Owens, GE, King, K, Gurney, JG, Charpie, JR. Low renal oximetry correlates with acute kidney injury after infant cardiac surgery. Pediatr Cardiol 2011; 32: 183188.Google Scholar
21. Jenkins, KJ. Risk adjustment for congenital heart surgery: the RACHS-1 method. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2004; 7: 180184.Google Scholar
22. Bell, RS, Graham, CB, Stevenson, JK. Roentgenologic and clinical manifestations of neonatal necrotizing enterocolitis. Experience with 43 cases. Am J Roentgenol Radium Ther Nucl Med 1971; 112: 123134.Google Scholar
23. Ghanayem, NS, Dearani, JA, Welke, KF, et al. Gastrointestinal complications associated with the treatment of patients with congenital cardiac disease: consensus definitions from the Multi-Societal Database Committee for Pediatric and Congenital Heart Disease. Cardiol Young 2008; 18 (Suppl 2): 240244.Google Scholar
24. Dave, V, Brion, LP, Campbell, DE, Scheiner, M, Raab, C, Nafday, SM. Splanchnic tissue oxygenation, but not brain tissue oxygenation, increases after feeds in stable preterm neonates tolerating full bolus orogastric feeding. J Perinatol 2009; 29: 213218.Google Scholar
25. Fortune, PM, Wagstaff, M, Petros, AJ. Cerebro-splanchnic oxygenation ratio (CSOR) using near infrared spectroscopy may be able to predict splanchnic ischaemia in neonates. Intensive Care Med 2001; 27: 14011407.Google Scholar
26. Varela, JE, Cohn, SM, Giannotti, GD, et al. Near-infrared spectroscopy reflects changes in mesenteric and systemic perfusion during abdominal compartment syndrome. Surgery 2001; 129: 363370.Google Scholar
27. Cohn, SM, Varela, JE, Giannotti, G, et al. Splanchnic perfusion evaluation during hemorrhage and resuscitation with gastric near-infrared spectroscopy. J Trauma 2001; 50: 629634; discussion 634–635.CrossRefGoogle ScholarPubMed
28. Cortez, J, Gupta, M, Amaram, A, Pizzino, J, Sawhney, M, Sood, BG. Noninvasive evaluation of splanchnic tissue oxygenation using near-infrared spectroscopy in preterm neonates. J Matern Fetal Neonatal Med 2011; 24: 574582.Google Scholar
29. Gay, AN, Lazar, DA, Stoll, B, et al. Near-infrared spectroscopy measurement of abdominal tissue oxygenation is a useful indicator of intestinal blood flow and necrotizing enterocolitis in premature piglets. J Pediatr Surg 2011; 46: 10341040.Google Scholar
30. Petros, AJ, Heys, R, Tasker, RC, Fortune, PM, Roberts, I, Kiely, E. Near infrared spectroscopy can detect changes in splanchnic oxygen delivery in neonates during apnoeic episodes. Eur J Pediatr 1999; 158: 173174.Google Scholar
31. Bernal, NP, Hoffman, GM, Ghanayem, NS, Arca, MJ. Cerebral and somatic near-infrared spectroscopy in normal newborns. J Pediatr Surg 2010; 45: 13061310.Google Scholar