Hostname: page-component-78c5997874-94fs2 Total loading time: 0 Render date: 2024-11-19T09:31:15.026Z Has data issue: false hasContentIssue false

An instrument for measuring bacterial penetration through fabrics used for barrier clothing*

Published online by Cambridge University Press:  15 May 2009

Ulrika Ransjö
Affiliation:
The Instiute of Clinical Bacteriology, Uppsala University, Uppsala
Anna Hambraeus
Affiliation:
The Instiute of Clinical Bacteriology, Uppsala University, Uppsala
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

A new instrument has been designed to measure the penetration by rubbing of bacteria from cloth contaminated in the nursing of burn patients through fabrics designed for barrier garments. Most fabrics tested dry reduced the transfer of bacteria from the source cloth to about 10%, irrespective of the results of air filter tests, which agrees with mock nursing results. When the fabrics were tested against a wet surface, the transfer of bacteria rapidly reached 100% if the fabrics had a high wettability, but was slower for fabrics with a low wettability. Through closely woven waterproofed cotton, transfer was 5–25%, but increased three- to four-fold after ten launderings, in line with the water absorption. Transfer through plastic-laminated material was less than 1%. The results suggest that barrier garments should be made either of plastic or of recently waterproofed closely woven cotton at points of contact between nurse and patient where the clothes may be wetted by bacteria-containing wound secretions.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1979

References

REFERENCES

Beck, W. C. & Carlson, W. W. (1963). Aseptic barriers. Archives of Surgery 87, 288.CrossRefGoogle ScholarPubMed
Brigden, R. J. L. (1964). A water-repellent theatre drape. Reproofing ventile fabric. Nursing Times 60, 1651.Google ScholarPubMed
Charnley, J. & Eftekhar, N. (1969). Penetration of gown material by organisms from the surgeon's body. Lancet i, 172.CrossRefGoogle Scholar
Charnley, J. (1972). Postoperative infection after total hip-replacement with special reference to air contamination in the operating room. Clinical Orthopaedics 87, 167.CrossRefGoogle ScholarPubMed
Hambraeus, A. & Ransjö, U. (1977). Attempts to control clothes-borne infection in a burn unit. 1. Experimental investigations of some clothes for barrier nursing. Journal of Hygiene 79, 193.CrossRefGoogle Scholar
Hoborn, J. (1977). Mensch Bekleidung und Reinraumtechnik. Medita 7, 3.Google Scholar
Holt, R. J. (1971). Aerobic bacterial counts on human skin after bathing. Journal of Medical Microbiology 4, 319.CrossRefGoogle ScholarPubMed
Lidwell, O. M., Noble, W. C. & Dolphin, G. W. (1959). The use of radiation to estimate the numbers of micro-organisms in air-borne particles. Journal of Hygiene 57, 1959.CrossRefGoogle Scholar
Lidwell, O. M. (1967). Take-off of bacteria and viruses. In Airborne Microbes. Seventeenth symposium of the Society for General Microbiology, p. 116. Cambridge: University Press.Google Scholar
Lidwell, O. M. & Mackintosh, C. A. (1978). The evaluation of fabrics in relation to their use as protective garments in nursing and surgery. I. Physical measurements and bench tests. Journal of Hygiene 81, 433.CrossRefGoogle ScholarPubMed
Mitchell, N. J. & Gamble, D. R. (1974). Clothing design for operating room personnel. Lancet ii, 1133.CrossRefGoogle Scholar
Ransjö, U. (1979). Attempts to control clothes-borne infection in a burn unit: 2. Clothing routines in clinical use and the epidemiology of cross-colonization. Journal of Hygiene 82, 369.CrossRefGoogle Scholar
Rubbo, S. D. & Saunders, J. (1963). Liberation of organisms from contaminated textiles. Journal of Hygiene 61, 507.Google ScholarPubMed
Schrank, J. (1973). Investigation of clean-room garments. Chemische Rundschau 26, 1.Google Scholar
Seaman, R. E. & Weimar, R. D. (1973). Barrier properties of an air permeable, fine-fibre spunbonded polyethylene sheet. Unpublished, property of El DuPont De Nemours & Co. Inc., Wilmington, Delaware.Google Scholar