Microbiologic Surveillance of Duodenoscope Reprocessing at the Vienna University Hospital From November 2004 Through March 2015

Published online by Cambridge University Press:  22 June 2015

Helga Paula
Affiliation:
Department of Hospital Hygiene and Infection Control, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
Elisabeth Presterl*
Affiliation:
Department of Hospital Hygiene and Infection Control, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
Barbara Tribl
Affiliation:
Division of Gastroenterology and Hepatology, Department of Medicine III, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
Magda Diab-Elschahawi
Affiliation:
Department of Hospital Hygiene and Infection Control, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
*
Address correspondence to Elisabeth Presterl, MD, Clinical Institute of Hospital Hygiene, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria (elisabeth.presterl@meduniwien.ac.at).

Abstract

Bacterial contamination of duodenoscopes is attributed to difficulties with reprocessing the Albarran lever. Routine microbiologic surveillance data of endoscopes with Albarran lever retrospectively collected from November 2004 through March 2015 revealed no growth of microorganism at this specific site. Transmission of endoscope-associated infection is avoidable by following validated reprocessing procedures.

Infect Control Hosp Epidemiol 2015;36(10):1233–1235

Type
Concise Communications
Copyright
© 2015 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. US Food and Drug Administration. Endoscopic retrograde cholangiopancreatography (ERCP) duodenoscopes: FDA safety communication—design may impede effective cleaning. http://www.fda.gov/Safety/MedWatch/SafetyInformation/SafetyAlertsforHumanMedicalProducts/ucm434922.htm. Published February 19, 2015. Updated March 4, 2015. Accessed March 30, 2015.Google Scholar
2. Gastmeier, P, Vonberg, RP. Klebsiella spp. in endoscopy-associated infections: we may only be seeing the tip of the iceberg. Infection 2014;42:1521.Google Scholar
3. Kovaleva, J, Peters, FT, van der Mei, HC, Degener, JE. Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev 2013;26:231254.Google Scholar
4. Committee for Hospital Hygiene and Infection Control Prevention (KRINKO) at the Robert Koch Institute (RKI). Hygienic requirements for reprocessing endoscopes [German]. Bundesgesundheitsbl 2012;55:12441310.Google Scholar
5. Rutala, WA, Weber, DJ, the Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for disinfection and sterilization in healthcare facilities 2008. Atlanta, GA: Centers for Disease Control and Prevention.Google Scholar
6. Rutala, WA, Weber, DJ. Reprocessing endoscopes: United States perspective. J Hosp Infect 2004;56:S27S39.Google Scholar
7. Heeg, P. Reprocessing endoscopes: national recommendations with a special emphasis on cleaning—the German perspective. J Hosp Infect 2004;56:S23S26.Google Scholar
8. International Organization for Standardization (ISO). EN ISO 15883-4:2008(en). Washer-disinfectors—part 4: requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes. http://www.iso.org/iso/iso_catalogue/catalogue_tc/catalogue_detail.htm?csnumber=42060. Published 2008. Updated 2011.Google Scholar
9. AURES – Der österreichische Antibiotikaresistenz-Bericht 2013 [German]. AURES – The Austrian Antibiotic Resistance Report. http://bmg.gv.at/cms/home/attachments/9/2/1/CH1318/CMS1416214760260/aures2013.pdf. Updated November 2013. Accessed May 20, 2015.Google Scholar
10. Alfa, MJ, Olson, N, Al-Fadhaly, A. Cleaning efficacy of medical device washers in North American healthcare facilities. J Hosp Infect 2010;74:168177.Google Scholar