Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-27T01:40:18.634Z Has data issue: false hasContentIssue false

Cartilage ‘shoe’: a new technique for stabilisation of titanium total ossicular replacement prosthesis at centre of stapes footplate

Published online by Cambridge University Press:  08 March 2017

D Beutner
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Germany
J C Luers
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Germany
K B Huttenbrink*
Affiliation:
Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Germany
*
Address for correspondence: Prof Karl-Bernd Huttenbrink, Professor and Chairman, Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Kerpener Strasse 62, 50924 Cologne, Germany. Fax: +49 221 478 4793 E-mail: huttenbrink.k-b@uni-koeln.de

Abstract

Objectives:

After tympanoplasty using a total ossicular replacement prosthesis, many unsatisfactory hearing results are due to dislocation of the prosthesis.

Material and methods:

We developed a cartilage guide for stabilising the total ossicular replacement prosthesis in the oval window niche. An oval-shaped piece of cartilage measuring 2.5 × 3.5 mm with a central hole was precisely punched out of a thin cartilage plate. The cartilage was placed in the oval niche, and its hole centred the prosthesis on the stapes footplate.

Results:

Hearing results in 52 patients confirmed acoustically the effectiveness of this method of total ossicular replacement prosthesis stabilisation on the stapes footplate. Subsequent ‘second-look’ surgery revealed stable ingrowth of the cartilage ‘shoe’ into the oval niche.

Conclusion:

Such a cartilage shoe might address one of the causes of unsatisfactory hearing following ossicular chain reconstruction with a total ossicular replacement prosthesis.

Type
Main Article
Copyright
Copyright © JLO (1984) Limited 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Huttenbrink, KB. Biomechanical aspects of middle ear reconstruction. In: Jahnke, K, ed. Current Topics in Otolaryngology - Head and Neck Surgery. Middle Ear Surgery: Recent Advances and Future Directions. Stuttgart: Thieme, 2004;2351Google Scholar
2 Huttenbrink, KB. Surgical treatment of chronic otitis media. III: Middle ear reconstruction [in German]. HNO 1994;42:701–18Google Scholar
3 Katzke, D, Steinbach, E, Schodermaier, C. The evaluation of allogenous incus transplants removed during revision tympanoplasty [in German]. Arch Otorhinolaryngol 1982;235:525–8CrossRefGoogle Scholar
4 Smyth, GDL. TORPS: how have they fared after five years? J Laryngol Otol 1983;97:991–3CrossRefGoogle Scholar
5 Huttenbrink, KB, Zahnert, T, Wustenberg, EG, Hofmann, G. Titanium clip prosthesis. Otol Neurotol 2004;25:436–42CrossRefGoogle ScholarPubMed
6 Fisch, U, May, J. Tympanoplasty, Mastoidectomy and Stapes Surgery. Stuttgart, New York: Thieme, 1994Google Scholar
7 Murbe, D, Zahnert, T, Bornitz, M, Huttenbrink, KB. Acoustic properties of different cartilage reconstruction techniques of the tympanic membrane. Laryngoscope 2002;112:1769–76CrossRefGoogle ScholarPubMed
8 Zahnert, T, Huttenbrink, KB, Murbe, D, Bornitz, M. Experimental investigations of the use of cartilage in tympanic membrane reconstruction. Am J Otol 2000;21:322–8CrossRefGoogle ScholarPubMed
9 Huttenbrink, KB, Zahnert, T, Beutner, D, Hofmann, G. The cartilage guide: a solution for anchoring a columella-prosthesis on footplate [in German]. Laryngorhinootologie 2004;83:450–6Google Scholar
10 Dalchow, CV, Grun, D, Stupp, HF. Reconstruction of the ossicular chain with titanium implants. Otolaryngol Head Neck Surg 2001;125:628–30CrossRefGoogle ScholarPubMed
11 Ho, SY, Battista, RA, Wiet, RJ. Early results with titanium ossicular implants. Otol Neurotol 2003;24:149–52CrossRefGoogle ScholarPubMed
12 Krueger, WW, Feghali, JG, Shelton, C, Green, JD, Beatty, CW, Wilson, DF et al. Preliminary ossiculoplasty results using the Kurz titanium prostheses. Otol Neurotol 2002;23:836–9CrossRefGoogle ScholarPubMed
13 McComb, H. Osseointegrated titanium implants for the attachment of facial prostheses. Ann Plast Surg 1993;31:225–32CrossRefGoogle ScholarPubMed
14 Schwager, K. Titanium as an ossicular replacement material: results after 336 days of implantation in the rabbit. Am J Otol 1998;19:569–73Google ScholarPubMed
15 Schwager, K. Titanium as a biomaterial for ossicular replacement: results after implantation in the middle ear of the rabbit. Eur Arch Otorhinolaryngol 1998;255:396401CrossRefGoogle ScholarPubMed
16 Eiber, A, Freitag, HG, Schimanski, G, Zenner, HP. On the coupling of prostheses to the middle ear structure and its influence on sound transfer. In: Rosowski, JJ, Merchant, SN, eds. Second International Symposium on Middle-Ear Mechanics in Research and Otosurgery, Kugler Publications: The Hague, The Netherlands, 2000;297308Google Scholar
17 Jahnke, K. Progress in microsurgery of the middle ear [in German]. HNO 1987;35:113Google Scholar
18 Plester, D, Hildmann, H, Seinbach, E. Atlas of Ear Surgery [in German]. The Netherlands: Kohlhammer Verlag, 1989Google Scholar
19 Berenholz, LP, Rizer, FM, Burkey, JM, Schuring, AG, Lippy, WH. Ossiculoplasty in canal wall down mastoidectomy. Otolaryngol Head Neck Surg 2000;123:30–3CrossRefGoogle ScholarPubMed
20 Brackmann, DE, Sheehy, JL, Luxford, WM. TORPs and PORPs in tympanoplasty: a review of 1042 operations. Otolaryngol Head Neck Surg 1984;92:32–7CrossRefGoogle ScholarPubMed
21 Farrior, JB, Nichols, SW. Long-term results using ossicular grafts. Am J Otol 1996;17:386–92Google ScholarPubMed
22 Goldenberg, RA, Driver, M. Long-term results with hydroxylapatite middle ear implants. Otolaryngol Head Neck Surg 2000;122:635–42CrossRefGoogle ScholarPubMed
23 House, JW, Teufert, KB. Extrusion rates and hearing results in ossicular reconstruction. Otolaryngol Head Neck Surg 2001;125:135–41CrossRefGoogle ScholarPubMed
24 Quaranta, N, Fernandez-Vega, FS, Piazza, F, Zini, C. Closed tympanoplasty in cholesteatoma surgery: long-term (10 years) hearing results using cartilage ossiculoplasty. Eur Arch Otorhinolaryngol 2001;258:20–4CrossRefGoogle ScholarPubMed
25 Zenner, HP, Stegmaier, A, Lehner, R, Baumann, I, Zimmermann, R. Open Tubingen titanium prostheses for ossiculoplasty: a prospective clinical trial. Otol Neurotol 2001;22:582–9CrossRefGoogle ScholarPubMed
26 Anson, JB, Donaldson, JA. Surgical Anatomy of the Temporal Bone and Ear, 2nd edn. Philadelphia, USA: WB Saunders, 1973Google Scholar
27 Asai, M, Huber, AM, Goode, RL. Analysis of the best site on the stapes footplate for ossicular chain reconstruction. Acta Otolaryngol 1999;119:356–61Google ScholarPubMed
28 Neudert, M, Berner, M, Bornitz, M, Beleites, T, Ney, M, Zahnert, T. Osseointegration of prostheses on the stapes footplate: evaluation of the biomechanical feasibility by using a finite element model. J Assoc Res Otolaryngol 2007;8:411–21CrossRefGoogle ScholarPubMed
29 Sudhoff, H, Lindner, N, Gronemeyer, J, Dazert, S, Hildmann, H. Study of osteointegration of a titanium prosthesis to the stapes: observations on an accidentally extracted stapes. Otol Neurotol 2005;26:583–6CrossRefGoogle Scholar