Some calculations on the γ-ray dose produced by a 14 Mev. betasynchrotron using an internal target
Published online by Cambridge University Press: 24 October 2008
Extract
Relations are derived between the dose in r./min. delivered by the γ-ray beam from a betasynchrotron and the mean electron current which is incident on the internal target. Comparison with experiment shows that multiple passage of electrons through the target probably plays an important part in production of the γ-ray beam. Some possible effects connected with the multiple passage of electrons are discussed.
- Type
- Research Article
- Information
- Mathematical Proceedings of the Cambridge Philosophical Society , Volume 45 , Issue 2 , April 1949 , pp. 305 - 310
- Copyright
- Copyright © Cambridge Philosophical Society 1949
References
REFERENCES
- 3
- Cited by