Hostname: page-component-7bb8b95d7b-fmk2r Total loading time: 0 Render date: 2024-09-10T10:12:02.943Z Has data issue: false hasContentIssue false

Energy-Filtered Imaging

Published online by Cambridge University Press:  14 March 2018

J. Bentley*
Affiliation:
Oak Ridge National Laboratory

Extract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Over the several years that imaging energy filters have been available commercially, numerous and wide-ranging applications have demonstrated elemental mapping with a resolution approaching 1 nm. A few reports have even shown resolutions <0.4 nm. Elemental mapping by energy-filtered transmission electron microscopy (Eftem) is clearly an attractive and powerful tool, but some aspects of the techniques can be complex, with many pitfalls awaiting the unwary. This tutorial aims to cover some practical aspects of elemental mapping by Eftem. It is based largely on the author's work at the ORNL Share User Facility, where Eftem research has been performed since 1994 with a Gatan imaging filter (GIF) interfaced to a Philips CM30T operated at 300 kV with a LaB6 cathode. Most of the applications have been to metals and ceramics, emphasizing interfacial segregation and precipitation.

Type
Research Article
Copyright
Copyright © Microscopy Society of America 2000

References

1. Bentley, J. and Kenik, E.A., Proc. Annual MSA Meeting 52 (1994)1000.Google Scholar
2. Bentley, J. et al., Proc. Microscopy and Microanaiysis 1995, 268.CrossRefGoogle Scholar
3. Hall, E.L. and Bentley, J., Proc. Microscopy and Microanaiysis 1995, 260.Google Scholar
4. Bentley, J. et al., Proc. Microscopy and Microanaiysis 1996, 542.Google Scholar
5. Bentley, J. et al., Proc. EMAG95, Inst. Phys. Conf. Ser. 147, Bristol, IOP (1995) 187.Google Scholar
6. Bentley, J.,Microsc. Microanal. 3 (Suppl 2: Proceedings) (1997)533.Google Scholar
7. Bentiey, J. et al,, Microsc, Microanal, 3 (Suppl 2; Proceedings) (1997)975.Google Scholar
8. Hall, E.L. and Bentley, J., Mat. Res. Soc. Symp. Proc. 458 (1997)121.Google Scholar
9. Bentley, J. and Anderson, I.M., Proc. Microscopy and Microanalysis 1996, 532.Google Scholar
10. Anderson, I.M. and Bentley, J., Mat. Res. Soc. Symp. Proc. 458(1997)81.Google Scholar
11. Anderson, I.M. and Bentley, J., Microsc. Microanal. 3 (Suppl 2: Proceedings) (1997) 931.Google Scholar
12. Bentley, J. et al., Mat. Res. Soc. Symp. Proc. 517 (1998) 205.Google Scholar
13. Wittig, J.E. et al., Mat. Res. Soc. Symp. Proc. 517 (1998) 211.Google Scholar
14. Evans, N.D. and Bentley, J., Proc. Microscopy and Microanaiysis 1996,544.Google Scholar
15. Bentley, J., Microsc. Microanal. 4 (Suppl 2: Proceedings) (1998)158.Google Scholar
16. Bentley, J. et ai., Microsc. Microanal. 5 (Suppl 2: Proceedings) (1999) 136; ibid 634.Google Scholar
17. Bentley, J., Microsc. Microanal. 6 (Suppl 2: Proceedings) (2000) 362.Google Scholar
18. Wang, Z.L, Bentley, J. and Evans, N.D., J. Phys. Chem. B 103 (1999)751.Google Scholar
19. Wang, Z.L., Bentley, J. and Evans, N.D., Microsc. Microanal. 5 (Suppl 2: Proceedings) (1999) 102.CrossRefGoogle Scholar
20. Bentley, J., Walter, K.C. and Evans, N.D., Microsc. Microanal. 6 (Suppl 2: Proceedings) (2000) 154.Google Scholar
21.Research at the Oak Ridge National Laboratory (ORNL) Share User Facility sponsored by the Division of Materials Sciences and Engineering, U.S. Department of Energy, under contract DE-AC05-00OR22725 with UT-Bateile LLC. Thanks to my many collaborators but especially to Drs. Anderson, Ian, Carpenter, Ray, Evans, Neal, Ernie Hall, Ed Kenik, Libera, Matt, Pint, Bruce, Phil Rice, Sharma, Renu, Wang, Z.L. and Jim Wittig.Google Scholar