Hostname: page-component-77c89778f8-cnmwb Total loading time: 0 Render date: 2024-07-22T19:36:44.588Z Has data issue: false hasContentIssue false

An Updated Ion Polishing System for Tem Specimen Preparation of Materials

Published online by Cambridge University Press:  10 February 2011

R. Alani
Affiliation:
Gatan Inc., 6678 Owens Drive, Pleasanton, CA 94588
R. J. Mitro
Affiliation:
Gatan Inc., 6678 Owens Drive, Pleasanton, CA 94588
P. R. Swann
Affiliation:
Gatan Inc., 6678 Owens Drive, Pleasanton, CA 94588
Get access

Abstract

The construction and performance of an improved ion milling instrument are described. The updated instrument is based upon an earlier version fixed low angle ion milling system. The updated system employs two improved guns having the ability of independent variable milling angle adjustment, while operating at high voltage in the vacuum system. The milling rate of these ion guns is typically ≈ 90μm/hr/gun pair for copper at 5keV and 10°. Designed to compliment the variable angle ion gun is a new specimen holder which permits low angle double sided milling. The combination of these two features offers numerous single or double sided milling conditions to facilitate the production of higher quality TEM specimens in less time. The range of ion gun angles encompassed is 0° to 10° for single-sided milling and 0° to ± 10° for double-sided milling. The instrument also incorporates an electronic mechanism to generate directional sector milling which benefits primarily the production of cross sectional TEM specimens and heat sensitive materials since the ion guns are turned off for a portion of time during each revolution. Another new feature of the instrument is chemical ion milling which facilitates the preparation of certain compound semiconductors. The ability of this improved ion milling instrument for rapid ion polishing and improved specimen quality is demonstrated by a number of TEM images of metals, ceramics and semiconductors.

Type
Research Article
Copyright
Copyright © Materials Research Society 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Alani, R., Jones, J.S., and Swann, P.R., in Workshop on Specimen Preparation for TEM of Materials III, edited by Anderson, R.M., M, B. Tracy, and Bravman, J. C., Mater. Res. Soc. Proc., 254, p.43 (1991)Google Scholar
2. Alani, R. and Swann, P.R., in Workshop on Specimen Preparation for TEM of Materials II, edited by Anderson, R.M., Mater. Res. Soc. Proc., 199, 85 (1990)Google Scholar
3. Alani, R., Harper, R.G. and Swann, P.R., Proc. 50th. Ann. Meeting of EMSA, 394, (1992) 4. U. Helmersson and J.E. Sundgren, J. Elec. Micr. Tech. Vol.4, 361 (1986)Google Scholar
5. Shaapur, F. and Watson, K.A., in Workshop on Specimen Preparation for TEM of Materials III, edited by Anderson, R.M., Tracy, B. M and Bravman, J. C., Mater. Res. Soc. Proc., 254, p.177 (1991)Google Scholar
6. Gatan Model 600 DuoMill Instruction Manual (1989)Google Scholar
7. Chew, N.G. and Cullis, A.G., Ultramicroscopy, 23, p. 175 (1987)Google Scholar
8. Alani, R. and Swann, P. R., Proc. 27th. Ann. Meeting of MAS, p.s284, (1993)Google Scholar
9. Carpenter, G.J.C., Jackman, J.A., McCaffrey, J.P. and Alani, R., J. of the Micro. Soc. of Am. 1 (4), p.175, (1995)Google Scholar
10. Chichibu, S., Azuhata, T., Sota, T. and Nakamura, S., Appl. Phys. Lett. 69 (27) p.4188, (1996)Google Scholar