Hostname: page-component-84b7d79bbc-g78kv Total loading time: 0 Render date: 2024-07-26T22:20:43.919Z Has data issue: false hasContentIssue false

Electrical Characterization of Impurities in and Contacts on Mercuric Iodide

Published online by Cambridge University Press:  10 February 2011

J. M. Van Scyoc
Affiliation:
Advanced Electronics Manufacturing Technologies Department, Sandia National Laboratories, Livermore, CA 94550
T. S. Gilbert
Affiliation:
Advanced Electronics Manufacturing Technologies Department, Sandia National Laboratories, Livermore, CA 94550
R. B. James
Affiliation:
Advanced Electronics Manufacturing Technologies Department, Sandia National Laboratories, Livermore, CA 94550
Get access

Abstract

Mercuric iodide (HgI2) is a semiconductor that has shown great promise for use in roomtemperature high-resolution x-ray and gamma-ray spectrometers. Its widespread usage has been limited, however, by low yield and long-term reliability problems. The processing of this material is still in its infancy compared to silicon, so research efforts continue to pursue the root causes of device failures. Two likely sources of performance limitations are impurities and poor contacts. Significant efforts have been expended in developing and using various purification schemes. However, quantitative chemical analyses have shown that several metallic impurities still exist at the high ppb level. In addition, it has not yet been definitively determined which impurities are most problematic and at what level they have a detrimental effect. Leakage currents and currentvoltage measurements have been used to study the movement of mobile impurity-related defect centers in the bulk mercuric iodide. In particular, this method has been used to quantify the drift of metallic impurities, such as Ag and Cu, which are known to or believed to degrade HgI2 detectors. Four-point-probe sheet resistance measurements have been used to study the stability of contacts and the formation of reaction layers. In particular, such measurements have revealed that the Pd contacts currently used for the highest quality detectors are not as stable as previously thought, as the films of Pd react with the HgI2 to form the amalgam PdHg.

Type
Research Article
Copyright
Copyright © Materials Research Society 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Cross, E., Soria, E., and Buffleben, G., presented at the 9 th International Workshop on Room Temperature Semiconductor X and y-Ray Detectors, Associated Electronics, and Applications, September 21, 1995, Grenoble, France, and submitted to Nucl. Instr. and Meth. A.Google Scholar
2. Van Scyoc, J. M., James, R. B., Schlesinger, T. E., and Gilbert, T. S., in Defect and Impurity Engineered Semiconductors and Devices, edited by Ashok, S., Chevallier, J., Akasaki, I., Johnson, N. M., and Sopori, B. L. (Mater. Res. Soc. Proc. 378, Pittsburgh, PA 1995), pp. 795801.Google Scholar
3. Van Scyoc, J. M., James, R. B., Schlesinger, T. E., Gilbert, T. S., and Schieber, M., presented at the International Conference on Crystal Growth XI, June 22, 1995, Amsterdam, The Netherlands, and submitted to J. Crys. Growth.Google Scholar
4. Cross, E. S., Mroz, E., and Olivares, J. A., in Semiconductors for Room-Temperature Radiation Detector Applications, edited by James, R. B., Schlesinger, T. E., Siffert, P., and Franks, L. (Mater. Res. Soc. Proc. 302, Pittsburgh, PA 1993), pp. 6165.Google Scholar
5. Van Scyoc, J. M., James, R. B., Burger, A., Soria, E., Perrino, C., Cross, E., Schieber, M., and Natarajan, M., presented at the 9th International Workshop on Room Temperature Semiconductor X and y-Ray Detectors, Associated Electronics, and Applications, September 21, 1995, Grenoble, France, and submitted to Nucl. Instr. and Meth. A.Google Scholar
6. Van Scyoc, J. M., Schlesinger, T. E., James, R. B., Cheng, A. Y., Ortale, C., and van den Berg, L., in Semiconductors for Room-Temperature Radiation Detector Applications, edited by James, R. B., Schlesinger, T. E., Siffert, P., and Franks, L. (Mater. Res. Soc. Proc. 302, Pittsburgh, PA 1993), pp. 115120.Google Scholar
7. Van Scyoc, J. M., Schlesinger, T. E., Yao, H., James, R. B., Natarajan, M., Bao, X. J., Iwanczyk, J. S., Patt, B. E., and van den Berg, L., in Diagnostic Techniques for Semiconductor Materials Processing, edited by Glembocki, O. J., et al. (Mater. Res. Soc. Proc. 324, Pittsburgh, PA 1994), pp. 6571.Google Scholar
8. Medlin, D. L., Van Scyoc, J. M., Gilbert, T. S., Schlesinger, T. E., Boehme, D., Schieber, M., Natarajan, M., and James, R. B., presented at the 9th International Workshop on Room Temperature Semiconductor X and y-Ray Detectors, Associated Electronics, and Applications, September 1995, Grenoble, France, and submitted to Nucl. Instr. and Meth. A.Google Scholar