Hostname: page-component-77c89778f8-n9wrp Total loading time: 0 Render date: 2024-07-16T20:00:37.303Z Has data issue: false hasContentIssue false

Enzymatic Biosensors with Integrated Thin Film a-Si:H Photodiodes

Published online by Cambridge University Press:  31 January 2011

Ana Teresa Pereira
Affiliation:
apereira@inesc-mn.pt, INESC Microsistemas e Nanotecnologias and IN- Institute of Nanoscience and Nanotechnology, Lisbon, Portugal
Virginia Chu
Affiliation:
vchu@inesc-mn.pt, INESC Microsistemas e Nanotecnologias and IN- Institute of Nanoscience and Nanotechnology, Lisbon, Portugal
Duarte M. F. Prazeres
Affiliation:
miguelprazeres@inesc-mn.pt, Centro de Engenharia Biológica e Química, IBB – Institute of Biotechnology and Bioengineering, Instituto Superior Técnico, Lisbon, Portugal
Joao P. Conde
Affiliation:
joao.conde@ist.utl.pt, INESC Microsistemas e Nanotecnologias and IN- Institute of Nanoscience and Nanotechnology, Lisbon, Portugal
Get access

Abstract

A microfabricated amorphous silicon photodiode is used to detect chemiluminescent and colorimetric horseradish peroxidase (HRP) enzymatic reactions. Detections limits of 1 nM and 1 pM of HRP are obtained for chemiluminescent and colorimetric measurements, respectively, with the reactions carried out in solution volume of 50 μL in polystyrene microwells. Surface-adsorbed HRP can be detected with a limit of 1 fmol.cm-2 by both detection methods. Immunoassays were performed using HRP-labeled antibodies and the detection of specific antibody-antigen molecular recognition is demonstrated both in the plastic well and inside a microfluidic channel. The application of the a-Si:H/HRP system is extended by coupling HRP with oxidase enzyme systems for glucose detection and a sensitivity of 0.1 mmol/L was achieved.

Type
Research Article
Copyright
Copyright © Materials Research Society 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Azevedo, A. M. et al. , “Horseradish peroxidase: a valuable tool in biotechnology,” Biotechnology Annual Review, Vol 9, vol. 9, pp. 199247, 2003.Google Scholar
[2] Street, R. A., Hydrogenated amorphous silicon: Cambridge University Press, 1991.Google Scholar
[3] Pimentel, A. C. et al. , “Detection of chemiluminescence using an amorphous silicon photodiode,” Ieee Sensors Journal, vol. 7, pp. 415416, Mar-Apr 2007.Google Scholar
[4] Gouvea, A. et al. , “Colorimetric detection of molecular recognition reactions with an enzyme biolabel using a thin-film amorphous silicon photodiode on a glass substrate,” Sensors and Actuators B-Chemical, vol. 135, pp. 102107, Dec 2008.Google Scholar
[5] Pereira, A. T. et al. , “Chemiluminescent Detection of Horseradish Peroxidase Using an Integrated Amorphous Silicon Thin Film Photosensor,” IEEE Sensors Journal, Accepted for publication.Google Scholar