Hostname: page-component-84b7d79bbc-5lx2p Total loading time: 0 Render date: 2024-07-30T03:14:36.061Z Has data issue: false hasContentIssue false

Measurement of Thermal Diffusivity of Cvd diamond films using modified ac calorimetry

Published online by Cambridge University Press:  10 February 2011

Akikazu Maesono
Affiliation:
ULVAC Sinku Riko, 1-9-19 Hakusan-cho Midori-ku, Yokohama, 226, Japan
Ronald. P. Tye
Affiliation:
ULVAC Sinku Riko, 6 Riverside Drive, Andover, MA
Get access

Abstract

Many applications of thin films, especially for electronics devices, require that these materials, which are often anisotropic, have a very high thermal conductivity as well as uniform areal properties to ensure that reproducible performance be attained. These factors necessitate that measurements of thermal transport properties are required both to provide absolute application values for different heat flow directions as well as to evaluate uniformity and homogeneity of a wafer. For diamond, the combination of a very high thermal conductivity with limited size and form of available specimen presents unique challenges to the experimentalist. As a result, a modification of the ac calorimeter method has been developed to evaluate the thermal diffusivity of thin films.

Details of the technique will be provided together with examples of its use to evaluate thermal diffusivity and thermal conductivity of different CVD diamond film composites having thicknesses from 10µm to 600µm and free-standing films. In addition, results using this method will be compared. with those obtained by other techniques involved in a recent international round-robin measurements program designed to evaluate a potential standard method(s).

Type
Research Article
Copyright
Copyright © Materials Research Society 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Kraftmakher, Y.A., 1962, Zh. Prikl.Mekh, and Tekh. Fix5, 176180 Google Scholar
2. Sullivan, P. and Seidel, G., 1968, Phys. Rev. 173, 679685.Google Scholar
3. Hatta, I I., Gu, Y., Kato, R., and Maesono, A., 1994, Proceedings of the 22nd International Thermal Conductivity Conference, Technomic Publishing Co., Lancaster, PA, pp 461472.Google Scholar
4. Hatta, I., Kato, R., and Maesono, A., 1986, Japan J. Appl. Phys. 25(6), L493–L495.Google Scholar
5. Hatta, I., Hiraiwa, S., and Yao, H., 1989, Proceedings of Second Asian Thermophvsical Properties Conference, Chinese Society of Physics, Beijing, pp 543546.Google Scholar
6. Gu, Y. Q. and Hatta, I., 1991, Japan J. Appl. Phys. 30(5), 11371138.Google Scholar
7. Gu, Y. Q., Zhu, D. Z., He, X., 1993, High Temp- High Pres., 25, 553.Google Scholar
8. Hatta, I., Kato, R., and Maesono, A., 1987, Japan J. Appl. Phys. 26(3), 475478 Google Scholar
9. Funamoto, H., Nishikawa, A., Moriya, T., and Sangboni, K., 1985, Proceedings of Sixth Japan Symposium or Thermophysical Properties Japanese Society of Thermophysics, Tokyo, pp 177182.Google Scholar
10. Yamashita, S., Tokyo Gas Co. Ltd., Frontier Research Institute, Yokohama, Japan, 1992, Private Communication. See also Proceedings of Diamond 1992. Conference Organizers in Medicine, Science and Technology, Lausanne, Switzerland p13.101.Google Scholar
11. Gardinier, C. F., Crystallume, Inc., Menlo Park Ca, USA, 1993, Private Communication.Google Scholar
12. Graebner, J. E., Jin, S., Kammlott, G. W., Herb, J. A., and Gardinier, C. F., 1992, Appl. Phys. Lett, 60, 15761578.Google Scholar
13. Maesono, A., Tye, R. P. and Gardner, R. G., 1993, High Temp. - High Press. 25, 329.Google Scholar
14. Feldman, A., 1995, Applications of Diamond Films and Related Materials: Third International Conference; Eds Feldman, A., Tzeng, Y, Yarbrough, W. A., Yoshikawa, M., and Murakama, M., N.I.S.T., Washington, DC, pp 627630.Google Scholar