Hostname: page-component-5c6d5d7d68-wp2c8 Total loading time: 0 Render date: 2024-08-15T21:58:53.637Z Has data issue: false hasContentIssue false

Small Angle X-Ray Scattering Studies of Fatigue in Polystyrene

Published online by Cambridge University Press:  26 February 2011

H. R. Brown
Affiliation:
IBM Almaden Research Center, San Jose, CA 95120–6099
E. J. Kramer
Affiliation:
Department of Materials science and Engineering, Cornell University Ithaca, NY 14853
R. A. Bubeck
Affiliation:
Central Research, The Dow Chemical Company, Midland, Michigan 48674
Get access

Abstract

Small angle scattering has been used to study the mechanical fatigue of crazes in polystyrene. The high radiation intensity obtainable from a synchrotron has permitted the examination of the processes that occur during the fatigue in real time. Both the short term changes that occur within a single cycle and the long term changes that occur over many cycles have been observed.

Most of the craze growth, as measured by the scattering invariant obtained at peak deformation, occurred in the first cycle of fatigue. However the craze fibril diameter, obtained by Porod analysis, doubled over 250 cycles. As the volume of craze was not growing during during the fatigue this fibril diameter increase was believed to occur by change, that is coalescence, of the preexisting fibrils.

The SAXS patterns obtained at a number of different deformations within a single cycle were compared with calculated patterns obtained assuming that the fibrils bend in a sinusoidal manner. Good qualitative agreement was obtained so it was concluded that the craze fibrils showed considerable deformation as the craze was unloaded and then straightened out again on reloading. When the ratio of minimum to maximum deformation was decreased from 0.9 to 0.5 the fibril deformation (contraction) increased to 10% with the fibrils remaining straight. As the minimum deformation was decreased below this the craze stress tends to zero and fibril buckling was evident. The main changes in fatigue lifetime occurred over the regions where there fibrils were straight, perhaps because buckling involves relatively small deformations.

Type
Articles
Copyright
Copyright © Materials Research Society 1987

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Mills, P. J., Kramer, E. J. and Brown, H. R., J. Mat. Sci. 20,4413 (1985).CrossRefGoogle Scholar
2. Brown, H. R. and Kramer, E. J., J. Polym. Sci. Polym. Phys. Ed. 23, 1857 (1985).Google Scholar
3. Brown, H. R. and Njoku, G. N., J. Polym. Sci. Polym. Phys. Ed., 24,11 (1986).Google Scholar
4. Beardmore, P. and Rabinowitz, S., App. Polyn. Symp. 24, 25 (1974).Google Scholar
5. Sauer, J. A. and Chen, C. C., Adv. Polym. Sci. 52/3, 169 (1983).CrossRefGoogle Scholar
6. Lauterwasser, B. D. and Kramer, E. J., Phil. Mag. A39, 469 (1979).Google Scholar
7. Kambour, R. P. and Kopp, R. W., J. Polym. Sci., Polym. Phys. Ed. A2, 7, 183 (1969).Google Scholar
8. Döll, W., Adv. Polyn. Sci. 52/3, 106 (1983).Google Scholar
9. Imai, Y. and Ward, I. M., J. Mater. Sci. 20, 3842 (1985).Google Scholar
10. Paredes, E. and Fischer, E. W., Makromol. Chem. 180, 2707 (1979).Google Scholar
11. Brown, H. R. and Kramer, E. J., J. Macromol. Sci. - Phys. B19, 487 (1981).Google Scholar