X-Ray Nanoplasma Instruments and Tools

Published online by Cambridge University Press:  01 February 2011

Scott Bloom
Affiliation:
JMAR Research Division 3956. Sorrento Valley Road, San Diego, CA 92121, http://www.jmar.com
Harry Rieger
Affiliation:
JMAR Research Division 3956. Sorrento Valley Road, San Diego, CA 92121, http://www.jmar.com
Jim Alwan
Affiliation:
JMAR Research Division 3956. Sorrento Valley Road, San Diego, CA 92121, http://www.jmar.com
Get access

Abstract

Soft x-rays have wavelengths in the range of 1–15 nm and therefore the diffraction limited spot size of focused x-rays can be as small as 1.22 × the radiation wavelength, or less than 20 nm spot size. Using our pulsed x-ray source and focusing a small collected solid angle of this x-ray radiation to a sample provides enough power to form a very hot plasma that emits a range of radiation from UV through IR that can be collected and analyzed on a conventional optical spectrometer. In addition to diagnostic capabilities the instrument can be also used as a tool to form structures at nanometer scale resolution. Since the plasma is formed by ablating the target material with x-rays the target can be patterned or nanomachined using the plasma itself. It should be possible to pattern nanoscale devices by rastering the material under the nanoplasma. Finally in analogy to plasma assisted CVD processes, organometallic vapors could introduced into the sample chamber such that the nanoplasma locally plates out specific species of metals of other materials on the target at nanoscale sizes for forming devices, circuits, wires, etc. This paper presents a design for a nanoplasma instrument, predicted performance parameters will be presented, and development issues identified and discussed.

Type
Research Article
Copyright
Copyright © Materials Research Society 2005

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Ding, Y., Micheletto, R., Hanada, H., Nagamura, T., Okazaki, S., Rev. Sci. Instrum. 73 (2002) 3227.Google Scholar
2. Kossakovski, D., Beauchamp, J.L., Anal. Chem. 72 (2000) 4731.Google Scholar
3. Dutoit, B., Zeisel, D., Deckert, V., Zenobi, R., J. Phys. Chem. B 101 (1997) 6955.Google Scholar
4. “Soft X-ray Laser Produces 3 W Of Output At 1 nm” Photonics Online 4/1/99Google Scholar
5. “Tinier Chips, Then Life's Tiniest Secrets” Los Angeles Times 4/19/99Google Scholar
6. Turcu, E., Rieger, H., Forber, R., Campeau, S., Powers, M., French, G., Grygier, R., Foster, R., Mitchell, P., and Gaeta, C., “High power x-ray source for next generation lithography”, EUV, X-Ray and Neutron Optics and Sources, SPIE Conf. Proc., SPIE 3767, 1999 Google Scholar
7. Turcu, ICE., Rieger, H., Vladimirsky, Y., Grygier, R., Powers, M., Naungayan, J., Campeau, S., French, G., Forber, R., and Foster, R., “Microfocus Soft X-Ray Source Generated by a Compact High Power Laser plasma”, Advances in Laboratory X-ray Sources and Optics, SPIE Vol. 4141 (2000)Google Scholar
8. Rieger, H., JMAR Technologies, Inc. “X-ray Vision - The Tabletop Laser System Yields a Plasma X-ray Source” OE Magazine publication of SPIE-The International Society for Optical Engineers. March 2001.Google Scholar
9. Rieger, H. and Campeau, Serge300 W Diode Pumped Nd:YAG Laser System for Soft X-Ray Generation”, TOPS 2001 Advanced Solid-State Lasers, OSA Google Scholar
10. Gaeta, C. J., Rieger, H., Turcu, I.C.E., Forber, R.A., Campeau, S.M., Cassidy, K.L., Powers, M.F., Maldonado*, J.R., French, G., Naungayan, J., Kelsy, C., Hark, P., Morris, J. H., Foster, R. M., Smith, H.I., and Lim, M.H. “High Power Compact LaserPlasma Source for X-Ray Lithography”, Japanese J of Appl. Phys. June 2002.Google Scholar