Cement waste forms prepared by three processes, casting, cold pressing, and FUETAP (Formed Under Elevated Temperatures and Pressure) have been compared for their leachability by using the MCC-1 leach test. The results indicate that releases of plutonium are not controlled by the waste form matrix and that there is no significant overall advantage to any of the three cement processes from a leachability viewpoint.