Hostname: page-component-7479d7b7d-rvbq7 Total loading time: 0 Render date: 2024-07-11T07:25:15.142Z Has data issue: false hasContentIssue false

A Patch-Type Flexible Physiological Monitor on a Non-Woven Material

Published online by Cambridge University Press:  26 February 2011

Wen-Yang Chang
Affiliation:
wenyang@itri.org.tw, National Cheng Kung University, Department of Engineering Science, 1 University Road, Tainan, 701, Taiwan
Jin-Sheng Chang
Affiliation:
wenyang@itri.org.tw, Industrial Technology Research Institute, Microsystems Technology Center, No.31, Gongye 2nd Rd., Annan District, Tainan, 709, Taiwan
Chun-Hsun Chu
Affiliation:
wenyang@itri.org.tw, Industrial Technology Research Institute, Microsystems Technology Center, No.31, Gongye 2nd Rd., Annan District, Tainan, 709, Taiwan
Tzong-Che Ho
Affiliation:
wenyang@itri.org.tw, Industrial Technology Research Institute, Microsystems Technology Center, No.31, Gongye 2nd Rd., Annan District, Tainan, 709, Taiwan
Yu-Cheng Lin
Affiliation:
yuclin@mail.ncku.edu.tw, National Cheng Kung University, Department of Engineering Science, 1 University Road, Tainan, 701, Taiwan
Get access

Abstract

The study reported is about an integrated wireless physiological monitor module of the flexible patch type, used on a non-woven material to package this module by a hot press process. The module can monitor the body temperature and heart rate. Experimental results showed that the specification and accuracy should be 25-40 °C ± 0.5 °C and 50-200 bpm ± 2 bpm. The main advantage of the module is that the postural change can be monitored. At the same time, it has also a good adhesion between substrate and components, without crack of conductor trace line after bending the module repeatedly. Thickness is about 2 mm. The aim of this study is to speed up the physiological technology and to create more efficiency by miniaturization. In addition, the acceptance level of wearing it is increased by the small and ergonomic design.

Type
Research Article
Copyright
Copyright © Materials Research Society 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Lin, B. S., Lin, B. S., Chou, N. K., Chong, F. C. and Chen, S. J., IEEE Transactions on Information Technology in Biomedicine, 99 19 (2006)Google Scholar
2. Yu, S. N. and Cheng, J. C., 27th Annual IEEE Int. Conf. Engineering in Medicine and Biology Society, 22032206 (2005). IEEE-EMBS 2005.Google Scholar
3. Jones, L., Deo, N. and Lockyer, B., Int. Workshop on Wearable and Implantable Body Sensor Wearable and Implantable Body Sensor Networks, April 35, 2006, 4 (2006).Google Scholar
4. Catrysse, M., Puers, R., Hertleer, C., Langenhove, L. V., Egmond, H. V. and Matthys, D., 12th Int.Conf. Transducers, Solid-State Sensors, Actuators and Microsystems, 17581761 (2003).Google Scholar
5. Prado, M., Roa, L. M. and Javier, R. T., International Journal of Medical Informatics, 75 646657(2006).Google Scholar
6. Johan, C., Bart, H. and Robert, P., Sensors and Actuators A, 130 4853 (2006).Google Scholar