Hostname: page-component-77c89778f8-7drxs Total loading time: 0 Render date: 2024-07-21T08:24:40.976Z Has data issue: false hasContentIssue false

Simulation and experimental verificationof dose distributions of electron beams

Published online by Cambridge University Press:  21 March 2012

J. Šemnická
Affiliation:
Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Brehova 7, Prague 1, 115 19, Czech Republic Na Homolce Hospital, Medical Physics Department, Roentgenova 37/2, Prague 5, 150 00, Czech Republic
J. Klusoň
Affiliation:
Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Brehova 7, Prague 1, 115 19, Czech Republic
Get access

Abstract

Accurate dose calculations are very important in radiotherapy treatment planning. The Monte Carlo method has proven to be an accurate and reliable method for simulation of the dose distributions from electron beams and can provide theoretically more accurate distributions than conventional planning system algorithms (e.g. the Generalized Gaussian Pencil Beam algorithm) for more complex target configurations. The aim of this work was to assess the parameters and spectrum of a given electron beam (Varian CLINAC 2100 C/D) from experimental depth dose distribution and then simulate dose distributions in an experimental arrangement with a 3D polymer gel dosimeter. The comparison of data from experimental measurements, Monte Carlo calculations and the planning system enabled us to verify experimentally the simulation model and technique as well as the planning system results. Both simple and more complex systems (e.g. dose distributions close to different material interfaces) can be studied. The generation and influence of the “bremsstrahlung” photons in the electron beams was also analyzed using the simulation technique. The computations, experimental methods used and results obtained are presented and discussed.

Type
Research Article
Copyright
© EDP Sciences, 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Ahnesjö A. (2010) Beam characterization and dose modelling for electron beams, ESTRO Teaching Course on Dose Modelling and Verification for External Beam Radiotherapy, Seville, Spain, 14-18 March 2010.
Hyödynmaa S. (1991) Implementations of the generalized Gaussian pencil beam algorithm for three-dimensional electron beam dose planning, Espoo: Technical Research Centre of Finland. ISBN 951-38-3943-5.
Jette, D. et al. (1988) Electron dose calculation using multiple-scattering theory. A: Gaussian multiple-scattering theory. Med. Phys. 15 (2), 123-137.Google ScholarPubMed
Lax, I. et al. (1983) Electron beam dose planning using Gaussian beams. Improved radial dose profiles, Acta Radiol. Suppl. 364, 49-59.Google ScholarPubMed
Low, D.A. et al. (1998) A technique for the quantitative evaluation of dose distributions, Med. Phys. 25 (5), 656-661.Google ScholarPubMed
Novotny, J. et al. (2001) Energy and dose rate dependence of BANG-2 polymer-gel dosimeter, Med. Phys. 28 (8), 2379-2387.Google ScholarPubMed
Novotny, J. Jr. et al. (2002) Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry, Radiotherapy and Oncology, 63 (6), 223-230.Google ScholarPubMed
Pelowitz D.B. et al. (2005) MCNPXTM 2.5.0, Monte Carlo N-Particle Transport Code System for Multiparticle and High Energy Applications, LA-CP-05-0369 (2005).
Wei, J. et al. (2007) Reconstruction of electron spectra from depth doses with adaptive regularization, Med. Phys. 33 (2), 354-359. Google ScholarPubMed
Zhu, T.C. et al. (2001) Characteristics of bremsstrahlung in electron beams, Med. Phys. 28 (7), 1352-1358.Google ScholarPubMed