Hostname: page-component-7479d7b7d-t6hkb Total loading time: 0 Render date: 2024-07-13T23:47:30.408Z Has data issue: false hasContentIssue false

Results of a Research Programme to Develop the Aerodynamic Configuration of a Pitot-Static Tube Capable of Accurate Operation to Mach Number 5 and 150 000 feet

Published online by Cambridge University Press:  04 July 2016

Frederick O. Smetana*
Affiliation:
Department of Mechanical Engineering, North Carolina State of The University of North Carolina, Raleigh

Extract

A few years ago the United States Air Force became interested in developing a higher temperature version of its standard pitot-static tube capableA of accurate operation to Mach number 5 and 150 000 ft with angles of attack up to 14°. It soon became evident that the existing aerodynamic configuration was inadequate because (a) the sharp pitot pressure source could not be protected from high heat fluxes and temperatures, (b) the static pressure source geometry produced serious errors at Mach numbers above 3·0 for α> 5°, and (c) the static pressure source geometry could be responsible for unacceptably high lag above 100 000 ft altitude because it consists of two orifices of only 0·070 in diameter.

Type
Research Article
Copyright
Copyright © Royal Aeronautical Society 1965

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)