Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-11-23T15:23:40.646Z Has data issue: false hasContentIssue false

the effect of the position of an additional systemic-to-pulmonary shunt on the fluid dynamics of the bidirectional cavo-pulmonary anastomosis

Published online by Cambridge University Press:  23 September 2005

francesca gervaso
Affiliation:
bioengineering department and laboratory of biological structure mechanics, politecnico di milano, milan, italy
silvia kull
Affiliation:
laboratory for biomaterials and graft technology and lad laboratory, institute of clinical physiology, national research council, massa and pisa, italy
giancarlo pennati
Affiliation:
bioengineering department and laboratory of biological structure mechanics, politecnico di milano, milan, italy
francesco migliavacca
Affiliation:
bioengineering department and laboratory of biological structure mechanics, politecnico di milano, milan, italy
gabriele dubini
Affiliation:
structural engineering department and laboratory of biological structure mechanics, politecnico di milano, milan, italy
vincenzo s. luisi
Affiliation:
department of paediatric cardiac surgery, “g. pasquinucci” hospital, institute of clinical physiology, national research council, massa and pisa, italy

Abstract

the bidirectional cavo-pulmonary anastomosis is a well-established palliative procedure for patients with a functionally univentricular circulation. it is usually considered one step in preparation for fontan procedure, but it may be performed as a long-term palliation for patients deemed to be at high-risk. in this subset of patients, a valuable surgical option could be to add, or maintain, an additional source of flow of blood to the lungs, either derived from a patent but banded trunk or one protected by native pulmonary stenosis, or a systemic-to-pulmonary arterial shunt. the risk and benefits of providing an additional source of pulmonary flow after construction of a bidirectional cavopulmonary anastomosis are strongly debated. in terms of benefit, the arterial saturation of oxygen is increased due to the greater ratio of pulmonary-to-systemic flow, arteriovenous fistulas are prevented and, as a consequence of the arterial pulsatile flow, the pulmonary arteries are stimulated to grow. the most significant drawbacks are volume overload of the functionally single ventricle, and higher pressures compared to an isolated bidirectional cavopulmonary anastomosis.

Type
original article
Copyright
2004 cambridge university press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)