Hostname: page-component-78c5997874-lj6df Total loading time: 0 Render date: 2024-11-19T15:40:28.604Z Has data issue: false hasContentIssue false

A novel sink drain cover prevents dispersal of microorganisms from contaminated sink drains

Published online by Cambridge University Press:  30 August 2018

Scott H. Livingston
Affiliation:
Case Western Reserve University School of Medicine, Cleveland, Ohio Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Jennifer L. Cadnum
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Scott Gestrich
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Annette L. Jencson
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Curtis J. Donskey*
Affiliation:
Case Western Reserve University School of Medicine, Cleveland, Ohio Geriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
*
Author for correspondence: Curtis J. Donskey, MD, Geriatric Research, Education, and Clinical Center 1110W, Louis Stokes Cleveland VA Medical Center, 10701 East Boulevard, Cleveland, Ohio 44106. E-mail: Curtis.Donskey@va.gov

Abstract

In hospital sinks, a novel plastic drain cover was effective in preventing dispersal of gram-negative bacilli and fluorescent gel associated with splattering of flowing water. Our findings suggest that the sink drain covers could provide a simple means to reduce dissemination of pathogens from contaminated sinks.

Type
Concise Communication
Copyright
© 2018 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Kanamori, H, Weber, DJ, Rutala, WA. Healthcare outbreaks associated with a water reservoir and infection prevention strategies. Clin Infect Dis 2016;62:14231435.Google Scholar
2. Kizny Gordon, AE, Mathers, AJ, Cheong, EYL, et al. The hospital water environment as a reservoir for carbapenem-resistant organisms causing hospital-acquired infections-a systematic review of the literature. Clin Infect Dis 2017 May 15;64:14351444.Google Scholar
3. Decker, BK, Palmore, TN. Hospital water and opportunities for infection prevention. Curr Infect Dis Rep 2014;16:432.Google Scholar
4. Hota, S, Hirji, Z, Stockton, K, Lemieux, C, Dedier, H, Wolfaardt, G, Gardam, MA. Outbreak of multidrug-resistant Pseudomonas aeruginosa colonization and infection secondary to imperfect intensive care unit room design. Infect Control Hosp Epidemiol 2009;30:2533.Google Scholar
5. Kotay, S, Chai, W, Guilford, W, Barry, K, Mathers, AJ. Spread from the sink to the patient: in situ study using green fluorescent protein (GFP) expressing-Escherichia coli to model bacterial dispersion from hand washing sink trap reservoirs. Appl Environ Microbiol 2017;83(8):pii:e0332716.Google Scholar
6. Gbaguidi-Haore, H, Varin, A, Cholley, P, Thouverez, M, Hocquet, D, Bertrand, X. A bundle of measures to control an outbreak of Pseudomonas aeruginosa associated with P-trap contamination. Infect Control Hosp Epidemiol 2018;39:164169.Google Scholar
7. Mathers, AJ, Vegesana, K, German Mesner, I, et al. Intensive care unit wastewater interventions to prevent transmission of multi-species Klebsiella pneumoniae carbapenemase (KPC)–producing organisms. Clin Infect Dis 2018. doi: 10.1093/cid/ciy052.Google Scholar
8. Hopman, J, Tostmann, A, Wertheim, H, et al. Reduced rate of intensive care unit acquired gram-negative bacilli after removal of sinks and introduction of 'water-free' patient care. Antimicrob Resist Infect Control 2017;6:59.Google Scholar
9. Wolf, I, Bergervoet, PW, Sebens, FW, van den Oever, HL, Savelkoul, PH, van der Zwet, WC. The sink as a correctable source of extended-spectrum β-lactamase contamination for patients in the intensive care unit. J Hosp Infect 2014;87:126130.Google Scholar
10. Deasy, EC, Moloney, EM, Boyle, MA, et al. Minimizing microbial contamination risk simultaneously from multiple hospital washbasins by automated cleaning and disinfection of U-bends with electrochemically activated solutions. J Hosp Infect 2018. doi: 10.1016/j.jhin.2018.01.012 Google Scholar