Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-29T11:57:09.088Z Has data issue: false hasContentIssue false

Some Observations on the Migration of Proteus mirabilis and Other Urinary Tract Pathogens Over Foley Catheters

Published online by Cambridge University Press:  02 January 2015

Gareth J. Williams
Affiliation:
Welsh School of Pharmacy, Cardiff University, Cardiff, Wales, UK
David J. Stickler*
Affiliation:
Cardiff School of Biosciences, Cardiff University, Cardiff, Wales, UK
*
Cardiff School of Biosciences, Main Building, Museum Avenue, Cardiff CF10 3TL, Wales, UK (stickler@cf.ac.uk)

Abstract

The ability of uropathogens to migrate along external surfaces of silicone Foley catheters was examined. Proteus mirabilis and Pseudomonas aeruginosa were the most motile organisms. P. aeruginosa migrated over both triclosan-impregnated and nitrofurazone-impregnated catheters, but these antibacterials inhibited the migration of P. mirabilis.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Darouiche, RO. Device-associated infections: a macroproblem that starts with microadherence. Clin Infect Dis 2001;33:15671572.CrossRefGoogle ScholarPubMed
2.Tambyah, PA, Halvorson, KT, Maki, DG. A prospective study of pathogenesis of catheter-associated urinary tract infections. Mayo Clin Proc 1999;74:131136.CrossRefGoogle ScholarPubMed
3.Gaonkar, TA, Sampath, LA, Modak, SM. Evaluation of the antimicrobial efficacy of urinary catheters impregnated with antiseptics in an in vitro urinary tract model. Infect Control Hosp Epidemiol 2003;24:506513.CrossRefGoogle Scholar
4.Sabbuba, N, Hughes, G, Stickler, DJ. The migration of Proteus mirabilis and other urinary tract pathogens over Foley catheters. BJU Int 2002;89:5560.CrossRefGoogle ScholarPubMed
5.Jones, BV, Young, R, Mahenthiralingam, E, Stickler, DJ. Ultrastructure of Proteus mirabilis swarmer cell rafts and role of swarming in catheter-associated urinary tract infection. Infect Immun 2004;72:39413950.Google Scholar
6.Gaonkar, TA, Caraos, L, Modak, S. Efficacy of a silicone urinary catheter impregnated with Chlorhexidine and triclosan against colonization with Proteus mirabilis and other uropathogens. Infect Control Hosp Epidemiol 2007;28:596598.Google Scholar
7.Morris, NS, Stickler, DJ, McLean, RJ. The development of bacterial biofilms on indwelling urethral catheters. World J Urol 1999;17:345350.CrossRefGoogle ScholarPubMed
8.Stickler, DJ, Jones, GLI, Russell, AD. Control of encrustation and blockage of Foley catheters. Lancet 2003;361:14351437.CrossRefGoogle ScholarPubMed
9.Jones, GLI, Russell, AD, Caliskan, Z, Stickler, DJ. A strategy for the control of catheter blockage by crystalline Proteus mirabilis biofilm using the antibacterial agent triclosan. Eur Urol 2005;48:838845.CrossRefGoogle ScholarPubMed
10.Lambert, HP, O'Grady, FW. Antibiotic and Chemotherapy. 6th ed. Edinburgh, Scotland: Churchill Livingstone; 1992.Google Scholar
11.Russell, AD. Whither triclosan? J Antimicrob Chemother 2004;53:693695.CrossRefGoogle ScholarPubMed