Abstract

In considering the onset of instability of an electrically conducting fluid between rotating permeable perfectly conducting cylinders in an applied axial magnetic field, it is found that oscillatory axially symmetric modes occur at large values of Hartmann number, in addition to the usual stationary modes. Results are presented showing the effect of the oscillatory modes on the criterion of onset of instability.

The asymptotic behaviour of the stability criterion is considered in the limit of very large radial Reynolds number, and also in the limit where both the radial Reynolds number and the Hartmann number are large.

Type
Research Article
Copyright
© 1969 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Chandrasekhar, S. 1961 Hydrodynamic and Hydromagnetic Stability Oxford: Clarendon.
Chang, T. S. & Sartory, W. K. 1967a Hydromagnetic stability of dissipative flow between rotating permeable cylinders. Part 1. Stationary critical modes J. Fluid Mech. 27, 65.Google Scholar
Chang, T. S. & Sartory, W. K. 1967b On the onset of instability by oscillatory modes in hydromagnetic Couette flow. Proc. Roy. Soc. A 301, 451.Google Scholar