Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-24T00:34:25.890Z Has data issue: false hasContentIssue false

Errors in the determination of ablation using stakes: comments on Dr. Vallon's letter

Published online by Cambridge University Press:  30 January 2017

J. F. Nye*
Affiliation:
H. H. Wills Physics Laboratory, University of Bristol, Bristol, England
Rights & Permissions [Opens in a new window]

Abstract

Type
Correspondence
Copyright
Copyright © International Glaciological Society 1968

Sir,

It may just be worth adding the following remark to M. Vallon’s letter. When the strain of the ice over the interval considered is large it is perhaps not immediately obvious how to calculate the correction term, because the length of stake buried in the ice, the gauge Length, is changing over the interval in an irregular way, as the ablation rate changes. But, if one assumes that the vertical strain-rate

is constant, it is easy to show that

where b is the true ablation, e is the length of stake exposed (the apparent ablation), Δt is the time interval, and

is the Lime average of the length of stake between the anchored point (which may be the bottom of the stake) and the surface. This holds for any variation in ablation rate, however irregular.
will not normally be known accurately, and must be estimated from the varying ablation rate over the interval.

21 August 1967