Hostname: page-component-78c5997874-g7gxr Total loading time: 0 Render date: 2024-11-18T23:01:00.219Z Has data issue: false hasContentIssue false

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and RapidArc in low grade mucoepidermoid carcinoma of the salivary gland: a single institutional experience

Published online by Cambridge University Press:  15 October 2020

Amna Ghaffar
Affiliation:
Department of Medical Physics, Shaukat Khannum Memorial Cancer Hospital and Research Centre, Lahore, Pakistan
Muhammad Yousaf
Affiliation:
Department of Medical Physics, Shaukat Khannum Memorial Cancer Hospital and Research Centre, Lahore, Pakistan
Sajid Anees Minhas
Affiliation:
Department of Medical Physics, Shaukat Khannum Memorial Cancer Hospital and Research Centre, Lahore, Pakistan
Rizwan Hameed
Affiliation:
Department of Medical Physics, Shaukat Khannum Memorial Cancer Hospital and Research Centre, Lahore, Pakistan
Umair Zafar
Affiliation:
Department of Medical Physics, Shaukat Khannum Memorial Cancer Hospital and Research Centre, Lahore, Pakistan
Khalid Iqbal
Affiliation:
Department of Medical Physics, Shaukat Khannum Memorial Cancer Hospital and Research Centre, Lahore, Pakistan

Abstract

Purpose:

To report a single-institution experience of intensity-modulated radiotherapy (IMRT) and RapidArc treatment plans for the patients treated with low grade mucoepidermoid carcinoma (MEC) of the salivary gland while sparing the organs at risk (OARs) within tolerance limits.

Material and Methods:

Twenty-five patients with MEC were selected to develop and analyse the treatment plans using both of the techniques. Dose distributions were calculated using Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). Plans were generated to deliver the dose of 6000 cGy in 30 fractions. For IMRT, seven angle plans were used and for RapidArc, two half arcs were used with the same 6 MV photon beam. Quality of treatment plans was evaluated by using parameters such as, coverage, conformity index (CI), homogeneity index (HI), gradient index (GI), unified dosimetry index (UDI), dose volume histogram, delivery time and OARs sparing for IMRT and RapidArc plans.

Results:

The analysis revealed that IMRT and RapidArc coverages are 0·90 and 0·94, respectively; CIs are 1·15 and 1·10, respectively; HIs are 1·12 and 1·07, respectively; GIs are 0·94 and 0·98, respectively. Average UDI values for RapidArc and IMRT are 1·09 and 1·11, respectively. Integral dose comparison shows better OAR sparing for RapidArc. RapidArc plans have the shorter beam on time (45%) in comparison with IMRT plans.

Conclusion:

Planning constraints were achieved in both techniques. However, RapidArc showed better quality treatment plan, OARs sparing and shorter delivery time as compared to IMRT.

Type
Original Article
Copyright
© The Author(s), 2020. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Boahene, DK, Olsen, KD, Lewis, JE, Pinheiro, AD, Pankratz, VS, Bagniewski, SM. Mucoepidermoid carcinoma of the parotid gland: the Mayo clinic experience. Arch Otolaryngol Head Neck Surg 2004; 130 (7): 849856.CrossRefGoogle ScholarPubMed
Otto, K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys 2008; 35 (1): 310317.CrossRefGoogle Scholar
Iqbal, K, Isa, M, Buzdar, SA, Gifford, KA, Afzal, M. Treatment planning evaluation of sliding window and multiple static segments technique in intensity modulated radiotherapy. Rep Pract Oncol Radiother 2013; 18 (2): 101106.CrossRefGoogle Scholar
Teoh, M, Clark, CH, Wood, K, Whitaker, S, Nisbet, A. Volumetric modulated arc therapy: a review of current literature and clinical use in practice. Brit J Radiol 2011; 84 (1007): 967996.CrossRefGoogle ScholarPubMed
Ashamalla, H, Tejwani, A, Parameritis, I, et al. Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer. Radiat Oncol J 2013; 31 (2): 104.CrossRefGoogle ScholarPubMed
Mayo, CS, Ding, L, Addesa, A, Kadish, S, Fitzgerald, TJ, Moser, R. Initial experience with volumetric IMRT (RapidArc) for intracranial stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 2010; 78 (5): 14571466.CrossRefGoogle ScholarPubMed
Yin, L, Wu, H, Gong, J, et al. Volumetric-modulated arc therapy vs c-IMRT in esophageal cancer: A treatment planning comparison. World J Gastroenterol 2012; 18 (37): 5266.Google ScholarPubMed
Rao, M, Yang, W, Chen, F, et al. Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: plan quality, delivery efficiency and accuracy. Med Phys 2010; 37 (3): 13501359.CrossRefGoogle ScholarPubMed
Cozzi, L, Dinshaw, KA, Shrivastava, SK, et al. A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol 2008; 89 (2): 180191.CrossRefGoogle ScholarPubMed
Otto, K, Milette, M, Wu, J. Temporal delivery efficiency of a novel single gantry arc optimization technique for treatment of recurrent nasopharynx cancer. Int J Radiat Oncol Biol Phys 2007; 69 (3): S703.CrossRefGoogle Scholar
Zhai, DY, Yin, Y, Gong, GZ, et al. RapidArc radiotherapy for whole pelvic lymph node in cervical cancer with 6 and 15 MV: a treatment planning comparison with fixed field IMRT. J Radiat Res 2013; 54 (1): 166173.CrossRefGoogle ScholarPubMed
Atiq, A., Atiq, M., Iqbal, K., et al. A comparative study of RapidArc and intensity-modulated radiotherapy plan quality for cervical cancer treatment. Indian J Cancer 2018; 55: 74.CrossRefGoogle ScholarPubMed
Akpati, H, Kim, C, Kim, B, Park, T, Meek, A. Unified dosimetry index (UDI): a figure of merit for ranking treatment plans. J Appl Clin Med Phys 2008; 9 (3): 99108.CrossRefGoogle ScholarPubMed
Krishna, GS, Srinivas, V, Ayyangar, KM, Reddy, PY. Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans. J Med Phys 2016; 41 (3): 192.CrossRefGoogle ScholarPubMed
Murphy, MJ, Chang, S, Gibbs, I, Le, QT, Martin, D, Kim, D. Image-guided radiosurgery in the treatment of spinal metastases. Neurosurg Focus 2001; 11 (6): 17.CrossRefGoogle ScholarPubMed
Das, IJ, Cheng, CW, Chopra, KL, Mitra, RK, Srivastava, SP, Glatstein, E. Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems. J Nat Cancer Inst 2008; 100 (5): 300307.CrossRefGoogle ScholarPubMed
Shaw, E, Kline, R, Gillin, M, et al. Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys 1993; 27 (5): 12311239.CrossRefGoogle ScholarPubMed
Atiq, A, Atiq, M, Iqbal, K, Shamsi, QA, Buzdar, SA. Evaluation of various dose homogeneity indices for treatment of patients with cervix cancer using intensity-modulated radiation therapy technique. J Radiother Prac 2019; 18 (1): 3237.CrossRefGoogle Scholar
Krishnan, J, Shetty, J, Rao, S, Hegde, S, Shambhavi, C. Comparison of rapid arc and intensity-modulated radiotherapy plans using unified dosimetry index and the impact of conformity index on unified dosimetry index evaluation. J Med Phys 2017; 42 (1): 14.CrossRefGoogle ScholarPubMed
Paddick, I, Lippitz, B. A simple dose gradient measurement tool to complement the conformity index. J Neurosurg 2006; 105 (Supplement): 194201.CrossRefGoogle ScholarPubMed
Weyh, A, Konski, A, Nalichowski, A, Maier, J, Lack, D. Lung SBRT: dosimetric and delivery comparison of RapidArc, TomoTherapy, and IMRT. J Appl Clin Med Phys 2013; 14 (4): 313.CrossRefGoogle Scholar
Oliver, M, Ansbacher, W, Beckham, WA. Comparing planning time, delivery time and plan quality for IMRT, RapidArc and Tomotherapy. J Appl Clin Med Phys 2009;10 (4): 117131.CrossRefGoogle ScholarPubMed
Nicolini, G, Clivio, A, Fogliata, A, Vanetti, E, Cozzi, L. Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy. Radiat Oncol 2009; 4 (1): 27.CrossRefGoogle ScholarPubMed
Pasciuti, K, Kuthpady, S, Anderson, A, Best, B, Waqar, S, Chowdhury, S. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans. Med Dosimet 2017; 42 (1): 16.CrossRefGoogle ScholarPubMed
Poon, DM, Kam, M, Leung, CM, et al. Dosimetric advantages and superior treatment delivery efficiency of RapidArc over conventional intensity-modulated radiotherapy in high-risk prostate cancer involving seminal vesicles and pelvic nodes. Clin Oncol 2013; 25 (12): 706712.CrossRefGoogle ScholarPubMed
Hall, EJ, Wuu, CS. Radiation-induced second cancers: the impact of 3D-CRT and IMRT. Int J Radiat Oncol Biol Phys 2003; 56 (1): 8388.CrossRefGoogle ScholarPubMed
D’Souza, WD, Rosen, II. Nontumor integral dose variation in conventional radiotherapy treatment planning. Med Phy 2003; 30 (8): 20652071.CrossRefGoogle ScholarPubMed
Aoyama, H, Westerly, DC, Mackie, TR, et al. Integral radiation dose to normal structures with conformal external beam radiation. Int J Radiat Oncol Biol Phys 2006; 64 (3): 962967.CrossRefGoogle ScholarPubMed