Article contents
Optimization of parameters of a copper plasma jet produced at the plasma focus device
Published online by Cambridge University Press: 24 August 2017
Abstract
The paper is aimed at optimization of parameters of a copper plasma jet produced at the DPF-1000U device, in which the inner electrode face was conically shaped. Preliminary information was obtained by numerical simulations of the plasma jet creation for different copper cones with the use of the two-dimensional magneto-hydrodynamic code KAROL. The simulations suggested that the cone height in the range of 4–7 cm should ensure a good plasma jet quality. The experimental data delivered by means of a 16-frame laser interferometer and a four-frame X-ray pinhole camera fully confirmed this conclusion. In the paper, we demonstrate the results for a 5 cm height cone. The eroded Cu plasma, swept up by the deuterium plasma sheath, was accelerated axially and compressed to very small diameter (3 mm) with an electron density of 7 × 1018 cm−3. The Cu plasma jet achieved a velocity of 5 × 107 cm/s and reached in the period of about 230 ns a distance (length) of 7 cm. The above results prove a successful adaptation of the plasma focus device to the metallic plasma jet generator.
Keywords
- Type
- Research Article
- Information
- Copyright
- Copyright © Cambridge University Press 2017
References
REFERENCES
- 5
- Cited by