Oxygen partial pressures; control, variation, and measurement in quench furnaces at one atmosphere total pressure

Published online by Cambridge University Press:  05 July 2018

Gordon M. Biggar*
Affiliation:
Grant Institute of Geology, University of Edinburgh, West Mains Road, Edinburgh EH9 3JW

Summary

Oxygen partial pressures in atmospheric-pressure quench furnaces were found to vary by as much as 0·5 in log fo2 when changes were made in gas flow rate and direction suggesting that careful analysis of the gas mixture supplied to a furnace is not a guarantee of the oxygen pressure that a sample in the furnace will attain. The use of magnesiowüstite compositions, with variable oxygen contents, as indicators of oxygen pressure is described.

Type
Research Article
Copyright
Copyright © The Mineralogical Society of Great Britain and Ireland 1974

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Biooar, (G. M.), 1969. Progress in Experimental Petrology, First Report, 105-8.Google Scholar
Biooar, (G. M.) and O'Hara, (M. J.), 1969a. Min. Mag., 37, I-15.Google Scholar
Biooar, (G. M.) 1969b. Ibid. 198-205.Google Scholar
Darken, (L. S.) and Gurrv, (R. W.), 1945. Journ. Amer. Chem. Soe., 67, 1398-1412.CrossRefGoogle Scholar
Katsura, (T.) and Kimcra, (S.), 1965. Bull. Chem. Soc. Japan,, 38, 1664-7o.CrossRefGoogle Scholar
Taylor, (R. W.), 1964. Amer. Min., 49, 1016-30.Google Scholar
Ulmer, (G. C.), Editor, 1971. Research techniques for high pressure and high temperature. New York (Springer-Verlag).CrossRefGoogle Scholar