Pressure corrections for a selection of piston-cylinder cell assemblies

Published online by Cambridge University Press:  05 July 2018

P. McDade*
Affiliation:
CETSEI, Department of Earth Sciences, University of Bristol, Wills Memorial Building, Bristol BS8 1RJ, UK
B. J. Wood
Affiliation:
CETSEI, Department of Earth Sciences, University of Bristol, Wills Memorial Building, Bristol BS8 1RJ, UK
W. Van Westrenen
Affiliation:
Geophysical Laboratory, Carnegie Institute of Washington, 5251 Broad Branch Road NW, Washington, DC 20015, USA
R. Brooker
Affiliation:
CETSEI, Department of Earth Sciences, University of Bristol, Wills Memorial Building, Bristol BS8 1RJ, UK
G. Gudmundsson
Affiliation:
IBRI, Keldnaholti, IS-112 Reykjavik, Iceland
H. Soulard
Affiliation:
IRSID, 57283 Mazières-les-Metz Cedex, France
J. Najorka
Affiliation:
CETSEI, Department of Earth Sciences, University of Bristol, Wills Memorial Building, Bristol BS8 1RJ, UK
J. Blundy
Affiliation:
CETSEI, Department of Earth Sciences, University of Bristol, Wills Memorial Building, Bristol BS8 1RJ, UK

Abstract

Piston-cylinder cell assemblies experience inhomogeneous pressure distribution upon pressurization due to the variable compressibilities of the cell components. This results in the sample experiencing a pressure lower than expected, given the applied force of the piston. Although the effect is generally compensated for by applying a ‘friction’ correction, there have been wide variations in the corrections applied for some of the harder cell materials. We have determined friction correction factors for a range of cell assemblies commonly used in our laboratory relative to select well-characterized phase equilibria. Single-sleeve NaCl cells require, using the piston-in technique, very small corrections of the order −0.05 GPa for 12.7 mm diameter, and less for larger diameter assemblies. Four separate calibrations of the single sleeve 12.7 mm BaCO3 cell show that it requires a correction of −9%. This factor is entirely independent of temperature and pressure within the range 1000 to 1600°C and 1.5 to 3.2 GPa. This result is in contrast to the results of Fram and Longhi (1992) who claim that the correction for BaCO3 cells is highly dependent on pressure. For the assemblies included in this study there is an increase in the pressure correction required in the order of 12.7 mm diameter NaCl-pyrex −3%; 19 mm talc-pyrex −3.6%; 12.7 mm BaCO3 −9% and 12.7 mm BaCO3-silica glass −13%.

Type
Research Article
Copyright
Copyright © The Mineralogical Society of Great Britain and Ireland 2002

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Akella, J. (1979) Quartz-coesite transition and the comparative friction measurements in piston cylinder apparatus using talc-alsimag-glass (TAG) and NaCl high pressure cells. Neues Jahrbuch für Mineralogie Monatshefte, 217224.Google Scholar
Bohlen, S.R. and Boettcher, A.L. (1982) The quartz–coesite transformation: a precise determination and the effects of other components. Journal of Geophysical Research, 87, 70737078.CrossRefGoogle Scholar
Bohlen, S.R., Essene, E.J. and Boettcher, A.L. (1980) Reinvestigation and application of olivine-quartzorthopyroxene barometry. Earth and Planetary Science Letters, 47, 110.CrossRefGoogle Scholar
Boyd, F.R. and England, J.L. (1960) Apparatus for phase equilibrium measurements at pressures of up to 50 kbars and temperatures to 1750°C. Journal of Geophysical Research, 65, 741748.CrossRefGoogle Scholar
Brodholt, J.P. and Wood, B.J. (1994) Measurements of the PVT properties of water to 25 kbars and 1600°C from synthetic fluid inclusions in corundum. Geochimica et Cosmochimica Acta, 58, 21432148.CrossRefGoogle Scholar
Brooker, R.A., Holloway, J.R. and Hervig, R. (1998) Reduction in piston-cylinder experiments: the detection of carbon Infiltration into platinum capsules. American Mineralogist, 83, 985994.CrossRefGoogle Scholar
Clark, S.P. (1959) Effect of pressure on the melting point of eight alkali halides. Journal of Chemical Physics, 31, 15261531.CrossRefGoogle Scholar
Edmond, J.M. and Patterson, M.S. (1971) Strength of solid pressure media and implications for high pressure apparatus. Contributions to Mineralogy and Petrology, 30, 141160.CrossRefGoogle Scholar
Fram, M.S. and Longhi, J. (1992) Phase equilibria of dikes associated with Proterozoic anorthosite complexes. American Mineralogist, 77, 605616.Google Scholar
Hays, J.F. and Bell, P.M. (1973) Albite-jadeite-quartz equilibrium: a hydrostatic determination. Transactions of the American Geophysical Union, 54, 482.Google Scholar
Hemmingway, B.S., Bohlen, S.R., Hankins, W.B., Westrum, E.F. and Kuskov, O.L. (1998) Heat capacity and thermodynamic properties for coesite and jadeite, re-examination of the quartz–coesite equilibrium boundary. American Mineralogist, 83, 409418.CrossRefGoogle Scholar
Holland, T.J.B. (1980) The reaction albite = jadeite + quartz determined experimentally in the range 600–1200°C. American Mineralogist, 65, 129137.Google Scholar
Johannes, W.J. (1978) Pressure comparing experiments with NaCl, AgCl, talc and pyrophyllite assemblies in a piston cylinder apparatus. Neues Jahrbuch für Mineralogie Monatshefte, 8492.Google Scholar
Johannes, W.J., Bell, P.M., Mao, H.K., Boettcher, A.L., Chipman, D.W., Hays, J.F., Newton, R.C. and Seifert, F. (1971) An interlaboratory comparison of piston-cylinder pressure calibration using the albite breakdown reaction. Contributions to Mineralogy and Petrology, 32, 2438.CrossRefGoogle Scholar
Kushiro, I. (1976) A new furnace assembly with a small temperature gradient in solid-media, high-pressure apparatus. Carnegie Institution of Washington Yearbook, 75, 281287.Google Scholar
Perkins, D. III, Holland, T.J.B. and Newton, R.C. (1981) The Al2O3 contents of enstatite in equilibrium with garnet in the system MgO–Al2O3–SiO2 at 15–40 kbar and 900º–1600°C. Contributions to Mineralogy and Petrology, 78, 99109.CrossRefGoogle Scholar
Withers, A.C., Kohn, S.C., Brooker, R.A. and Wood, B.J. (2000) A new method for determining the P-V-T properties of high-density H2O using NMR: results at 1.4–4.0 GPa and 700–1100°C. Geochimica et Cosmochimica Acta, 64, 10511057.CrossRefGoogle Scholar