Hostname: page-component-84b7d79bbc-x5cpj Total loading time: 0 Render date: 2024-07-26T02:27:40.540Z Has data issue: false hasContentIssue false

Highly Sensitive Aptamer-Based Method for the Detection of Cardiac Biomolecules on Silicon Dioxide Surfaces

Published online by Cambridge University Press:  02 April 2018

H. Hlukhova
Affiliation:
Bioelectronics, Institute of Complex Systems (ICS-8), Forschungszentrum Jülich, Wilhelm-Johnen-Straße, 52425Jülich, Germany
M. Menger
Affiliation:
Fraunhofer Institute for Cell Therapy and Immunology, Branch Bioanalytic and Bioprocesses (IZI-BB), Am Mühlenberg 13, 14476Potsdam, Germany
A. Offenhäusser
Affiliation:
Bioelectronics, Institute of Complex Systems (ICS-8), Forschungszentrum Jülich, Wilhelm-Johnen-Straße, 52425Jülich, Germany
S. Vitusevich*
Affiliation:
Bioelectronics, Institute of Complex Systems (ICS-8), Forschungszentrum Jülich, Wilhelm-Johnen-Straße, 52425Jülich, Germany
Get access

Abstract

In this work, we report on fabrication of the thin-films of silicon oxide dielectric layers on silicon with back-side contact and utilization of the structure to study the detection of human Troponin antigen (cTnI) molecules: the cardiac biomarkers for the early diagnosis of acute myocardial infraction. Aptamers are selectively bound to the target molecules and can block the binding epitope for further reaction like immobilization or interaction to any other molecules. In contrast to antibodies, the aptamers are smaller in size, which allows target molecules to be brought closer to the surface of the biosensor and, therefore, to enhance the molecular signal. The target molecule in this work is cTnI, which is located in the cardiac muscle tissue. As a reliable indicator of heart failure and injury, it is specifically considered for the diagnosis of myocardial infarctions. The solutions of Troponin molecules were studied in different concentrations range from 10 pg/μL to 1 ng/μL. For the electrical detection of cTnI, we used the field-effect capacitive electrolyte-insulator-semiconductor (EIS) technique, which is a robust method for the quantitative characterization of molecular layers. The measured values of capacitances and flat band voltages were used to acquire information about the properties of the molecular layers obtained using solutions with different troponin concentrations. It was shown that this method demonstrates high sensitivity to target cardiac biomolecules and opens up new perspectives for highly selective and sensitive cardiac biosensors developed on the basis of silicon nanowire structures.

Type
Articles
Copyright
Copyright © Materials Research Society 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

References:

Filatov, V.L., Katrukha, A.G., Bulargina, T.V., Gusev, N.B., Biochemistry, 64, 969–85 (1999).Google Scholar
Adams, J.E., Bedor, G.S., Davila-Roman, V.G., Delmez, J.A., Apple, F.S., Ladenson, J.H., Jaffe, A.S., Circulation, 88, 101106 (1993).CrossRefGoogle Scholar
Dorajj, G.S., Rassaee, M.J., Latifi, A.M., Pishgoo, B., Tavallaei, M., Journal of Biotechnology, 6, 208–80 (2015).Google Scholar
Kern, W., Puotinen, D., RCA Review, 187, (1970).Google Scholar
Thiviyanathan, V., Gorenstein, D.G., Proteomics Clinical Applications, 6, 563573 (2012).Google Scholar
Hauser, J.R., Ahmed, K., AIP Conference Proceedings, 235 (1998).Google Scholar
Hulme, E.C., Trevethick, M.A., British Journal of Pharmacology, 161, 12191237 (2010).Google Scholar
Jo, H., Gu, H., Jeon, W., Youn, H., Her, J., Kim, S.-K., Lee, J., Shin, J.H., Ban, C., Anal. Chemistry, 87, 98699875 (2015).CrossRefGoogle Scholar