Hostname: page-component-78c5997874-v9fdk Total loading time: 0 Render date: 2024-11-09T05:19:14.344Z Has data issue: false hasContentIssue false

A Computer Program to Facilitate Performance Assessment of Underground Low-Level Waste Concrete Vaults

Published online by Cambridge University Press:  15 February 2011

K. A. Snyder
Affiliation:
National Institute of Standards and Technology, Gaithersburg, MD, USA
J. R. Clifton
Affiliation:
National Institute of Standards and Technology, Gaithersburg, MD, USA
J. Pommersheim
Affiliation:
Bucknell University, Lewisberg, PA, USA
Get access

Abstract

A computer program (4SIGHT) to facilitate performance assessment of underground concrete vaults for low level waste (LLW) disposal facilities is being developed at the National Institute of Standards and Technology (NIST). Specifically, the program predicts the hydraulic conductivity and the service life of an underground concrete vault. The hydraulic conductivity estimate is based upon empirical relations. The service life is estimated from consideration of three major degradation processes: steel reinforcement corrosion, sulfate attack, and leaching. The performance prediction is based upon ion transport equations for both diffusion and advection. Most importantly, the computer program incorporates the synergistic degradation effects of all three processes, and their effect upon the transport coefficients.

Type
Research Article
Copyright
Copyright © Materials Research Society 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Snyder, K. A. and Clifton, J. R. (1995) 4SIGHT Manual: A Computer Program for Modelling Degradation of Underground Low Level Waste Concrete Vaults, NISTIR 5612, U.S. Department of Commerce.Google Scholar
[2] Clifton, J.R., and Knab, L.I. (1989) Service Life of Concrete, NISTIR 89–4086, U.S. Department of Commerce.Google Scholar
[3] Atkinson, A., and Hearne, J.A. (1989) Mechanistic models for the durability of concrete barriers exposed to sulfate-bearing groundwaters, in Scientific Basis for Nuclear Waste Management XIII, (eds. Oversby, V.M. and Brown, P.W.) Materials Research Society, Pittsburgh, Vol.176, pp. 149156.Google Scholar
[4] Landau, and Lifshitz, (1987) Fluid Mechanics, Pergamon Press, New York.Google Scholar
[5] Crank, (1967) The Mathematics of Diffusion, Oxford University Press, London.Google Scholar
[6] Slattery, J.C. (1972) Momentum, Energy, and Mass Transfer in Continua, McGraw-Hill Book Company, New York.Google Scholar
[7] Young, J.F. and Hansen, W. (1987) Volume relationships for C-S-H formation based on hydration stoichiometries, in Microstructural Development During Hydration of Cement, (eds. Struble, L.J. and Brown, P.W.) Materials Research Society, Pittsburgh, Vol.85, pp. 313322.Google Scholar
[8] Bentz, D. and Garboczi, E. (1991) Percolation of phases in a three-dimensional cement paste microstructural model, Cement and Concrete Research, Vol.21, pp. 325344.Google Scholar
[9] Atkinson, A., Nickerson, A.K., and Valentine, T.M. (1984) The mechanism of leaching from some cement-based nuclear wasteforms, Radioactive Waste Management and the Nuclear Fuel Cycle, Vol.4, 357378.Google Scholar
[10] Walton, J., Plansky, L., and Smith, R. (1990) Models for estimation of service life of concrete barriers in low-level radioactive waste disposal, NUREG/CR-5542, EGG-2597, Department of Energy.Google Scholar
[11] Garboczi, E.J., and Bentz, D.P. (1992) Computer simulation of the diffusivity of cement-based materials, Journal of Materials Science, Vol.27, pp. 20832092.Google Scholar
[12] Luping, T., and Nilsson, L. (1992) Rapid determination of the chloride diffusivity in concrete by applying an electric field, ACI Materials Journal, Vol.89, pp. 4953.Google Scholar
[13] Garboczi, E.J., Schwartz, L.M., and Bentz, D.P. (1995) Modelling the influence of the interfacial zone on the D.C. electrical conductivity of mortar, Journal of Advanced Cement-Based Materials, Vol.2, pp. 169181.Google Scholar
[14] Hearn, N., Hooton, R.D., and Mills, R.H. (1994) Pore structure and permeability, in Significance of tests and properties of Concrete and Concrete-Making Materials, (eds. Klieger, P. and Lamond, J.), ASTM, Philadelphia, pp. 240262.Google Scholar
[15] Bentz, D.P., and Garboczi, E.J. (1992) Guide to using HYDRA3D: A three-dimensional digital-image-based cement microstructural model, NISTIR 4746, Department of Commerce.Google Scholar
[16] Katz, A.J., and Thompson, A.H. (1986) Quantitative prediction of permeability in porous rock, Physical Review B, Vol.34, pp. 81798181.Google Scholar
[17] Roy, D.M., and Li, S. (1986) Investigation of relations between porosity, pore structure, and Cl- diffusion of fly ash and blended cement pastes, Cement and Concrete Research, Vol.16, pp. 749759.Google Scholar