Hostname: page-component-586b7cd67f-tf8b9 Total loading time: 0 Render date: 2024-11-25T20:29:18.786Z Has data issue: false hasContentIssue false

Durability of a reinforced concrete designed for the construction of an intermediate-level radioactive waste disposal facility

Published online by Cambridge University Press:  28 March 2012

G.S. Duffó
Affiliation:
Consejo Nacional de Investigaciones Científicas y Técnicas, Argentina Universidad Nacional de Gral. San Martín, Argentina Comisión Nacional de Energía Atómica, Departamento de Materiales, Av. Gral. Paz 1499 (1650), San Martín, Buenos Aires, Argentina. E-mail: duffo@cnea.gov.ar
E.A. Arva
Affiliation:
Comisión Nacional de Energía Atómica, Departamento de Materiales, Av. Gral. Paz 1499 (1650), San Martín, Buenos Aires, Argentina. E-mail: duffo@cnea.gov.ar
F.M. Schulz
Affiliation:
Consejo Nacional de Investigaciones Científicas y Técnicas, Argentina
D.R. Vazquez
Affiliation:
Comisión Nacional de Energía Atómica, Departamento de Materiales, Av. Gral. Paz 1499 (1650), San Martín, Buenos Aires, Argentina. E-mail: duffo@cnea.gov.ar
Get access

Abstract

The National Atomic Energy Commission of the Argentine Republic is developing a nuclear waste disposal management programme that contemplates the design and construction of a facility for the final disposal of intermediate-level radioactive wastes. The repository is based on the use of multiple, independent and redundant barriers. The major components are made in reinforced concrete so, the durability of these structures is an important aspect for the facility integrity. This work presents an investigation performed on a reinforced concrete specifically designed for this purpose, to predict the service life of the intermediate level radioactive waste disposal facility from data obtained with several techniques. Results obtained with corrosion sensors embedded in a concrete prototype are also included. The information obtained will be used for the final design of the facility in order to guarantee a service life more or equal than the foreseen durability for this type of facilities.

Type
Articles
Copyright
Copyright © Materials Research Society 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Joint convention on the safety of spent fuel management and on the safety of radioactive waste management. National Report. Argentina (2003), http://www.cab.cnea.gov.ar/residuos/CC2003/0002-SecA.pdf (accessed march/25/2011).Google Scholar
2. Schultz, F.M., Arva, E.A., Duffo, G.S., Studies concerning the reinforcement corrosion of concrete vaults for intermediate-level radioactive waste disposal, in: L’Hostis, V., Gens, R., Gallé, C. (Eds.), Long Term Performance of Cementitious Barriers and Reinforced Concrete in Nuclear Power Plants and Waste Management . RILEM Publications SARL, Paris, 2009, pp. 1321.Google Scholar
3. Duffó, G.S., Farina, S.B., Giordano, C.M., Characterization of solid embeddable reference electrodes for corrosion monitoring in reinforced concrete structures, Electrochim. Acta, 54 (2009) 20102020.10.1016/j.electacta.2008.08.025Google Scholar
4. Duffó, G.S., Farina, S.B., Giordano, C.M., Embeddable reference electrodes for corrosion monitoring of reinforced concrete structures. Mater. Corros. 61 (2010) 480489.10.1002/maco.200905346Google Scholar
5. ASTM C 876, Standard test method for half-cell potential for uncoated reinforcing steel in concrete, American Society of Testing and Materials, Philadelphia, 1987.Google Scholar
6. Stern, M., Geary, A.L., Electrochemical Polarization: I. A theoretical analysis of the shape of the polarization curve, J. Electrochem. Soc. 104 (1957) 5663.10.1149/1.2428496Google Scholar
7. Andrade, C., Alonso, M.C., Gonzalez, J.S., An initial effort to use the corrosion rate measurements for estimating rebar durability, in: Berke, N. S., Chaker, V., Whiting, W. D. (Eds.), Corrosion Rates of Steel in Concrete , ASTM STP 1065, ASTM International, Philadelphia, 1990, pp. 2937.10.1520/STP25013SGoogle Scholar
8. Duffó, G.S., Farina, S.B., Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures, Constr. Build. Mater. 23 (2009) 27462751.10.1016/j.conbuildmat.2009.04.001Google Scholar
9. Andrade, C., Martínez, I., Castellote, M., Zuloaga, P., Some principles of service life calculation of reinforcements and in situ corrosion monitoring by sensors in the radioactive waste containers of El Cabril disposal (Spain), J. of Nuclear Materials, 358 (2006), 8295.10.1016/j.jnucmat.2006.06.015Google Scholar
10. Andrade, M.C., Alonso, M. C., On-site measurements of corrosion rate of reinforcements, Constr. Build. Mater. 15 (2001) 141145.10.1016/S0950-0618(00)00063-5Google Scholar
11. Novak, P., Mala, R., Josta, L., Influence of pre-rusting on steel corrosion in concrete, Cem. Concr. Res. 31 (2001) 589593.10.1016/S0008-8846(01)00459-8Google Scholar