Novel Fabrication Process for the Integration of MEMS Devices with Thick Amorphous Soft Magnetic Field Concentrators

Published online by Cambridge University Press:  01 February 2011

Simon Brugger
Affiliation:
sbrugger@imtek.de, University of Freiburg - IMTEK, Department of Microsystems Engineering, Georges-Koehler-Allee 103, Freiburg, D-79110, Germany
Wilhelm Pfleging
Affiliation:
wilhelm.pfleging@imf.fzk.de, Forschungszentrum Karlsruhe GmbH, Institute for Materials Research I, Karlsruhe, 76021, Germany
Oliver Paul
Affiliation:
paul@imtek.de, University of Freiburg, Department of Microsystems Engineering (IMTEK), Freiburg, 79110, Germany
Get access

Abstract

This paper reports a novel fabrication process enabling the integration of mechanical MEMS devices with thick amorphous soft magnetic field concentrators. The integration process combines silicon on insulator technology for the MEMS device fabrication and epoxy-resin-based attachment of 18-µm-thick amorphous soft magnetic ribbons followed by a wet chemical structuring process. The fabrication process is reported on the basis of a field-concentrator-based resonant magnetic sensor combining an electrostatically driven micromechanical resonator and a planar magnetic field concentrator with two narrow gaps. For realization of the concentrator gaps, the integration process is extended by micro-patterning of the soft magnetic ribbons via UV-laser ablation using an excimer laser system. The characterization of the fabricated resonant magnetic sensor using a stroboscopic video microscope for in-plane motion measurement shows a high sensitivity of 390 kHz/T at a magnetic flux density of 158 µT.

Type
Research Article
Copyright
Copyright © Materials Research Society 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Schneider, M., Castagnetti, R., Allen, M.G and Baltes, H., Proc. of IEEE MEMS Conf., n151 (1995).Google Scholar
2 Drljača, P.M, Vincent, F., Besse, P.-A. and Popović, R.S, Sens. Actuators A 97–98, 10 (2002).Google Scholar
3 Schott, C., Racz, R. and Huber, S., Proc. of IEEE Sensors Conf., 959 (2005).Google Scholar
4 Schott, C., Racz, R. and Huber, S., Proc. of IEEE Sensors Conf., 977 (2004).Google Scholar
5 Taylor, W.P, Schneider, M. and Baltes, H., Dig. Tech. Papers Transducers 2, 1445 (1997).Google Scholar
6 Popovi, R.Sć, Drlja, P.Mča and Kejik, P., Sens. Actuators A 129, 94 (2006).Google Scholar
7 Perez, L., Aroca, C., Sánchez, P., López, E. and Sánchez, M.C., Sens. Actuators A 109, 208 (2004).Google Scholar
8 Brugger, S., Simon, P. and Paul, O., Proc. of IEEE Sensors Conf., 1016 (2006).Google Scholar
9 Brugger, S. and Paul, O., Dig. Tech. Papers Transducers, 2377 (2007).Google Scholar
10 Pfleging, W., Przybylski, M. and Brückner, H.J., Proc. of SPIE 6107, 61070G–1 (2006).Google Scholar