Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-24T08:13:32.693Z Has data issue: false hasContentIssue false

Current developments of robotic hip exoskeleton toward sensing, decision, and actuation: A review

Published online by Cambridge University Press:  15 July 2022

Canjun Yang
Affiliation:
Ningbo Research Institute, Zhejiang University, Ningbo, China School of Mechanical Engineering, Zhejiang University, Hangzhou, China School of Mechanical and Energy Engineering, NingboTech University, Ningbo, China
Linfan Yu
Affiliation:
Ningbo Research Institute, Zhejiang University, Ningbo, China School of Mechanical Engineering, Zhejiang University, Hangzhou, China
Linghui Xu
Affiliation:
Ningbo Research Institute, Zhejiang University, Ningbo, China School of Mechanical Engineering, Zhejiang University, Hangzhou, China
Zehao Yan
Affiliation:
Ningbo Research Institute, Zhejiang University, Ningbo, China School of Mechanical Engineering, Zhejiang University, Hangzhou, China
Dongming Hu
Affiliation:
School of Mechanical and Energy Engineering, NingboTech University, Ningbo, China
Sheng Zhang*
Affiliation:
Ningbo Research Institute, Zhejiang University, Ningbo, China School of Mechanical Engineering, Zhejiang University, Hangzhou, China
Wei Yang*
Affiliation:
Ningbo Research Institute, Zhejiang University, Ningbo, China School of Mechanical Engineering, Zhejiang University, Hangzhou, China School of Mechanical and Energy Engineering, NingboTech University, Ningbo, China
*
* Authors for correspondence: Sheng Zhang and Wei Yang, Ningbo Research Institute, Zhejiang University, Ningbo, China. Email: szhang1984@zju.edu.cn; simpleway@zju.edu.cn
* Authors for correspondence: Sheng Zhang and Wei Yang, Ningbo Research Institute, Zhejiang University, Ningbo, China. Email: szhang1984@zju.edu.cn; simpleway@zju.edu.cn

Abstract

The aging population is now a global challenge, and impaired walking ability is a common feature in the elderly. In addition, some occupations such as military and relief workers require extra physical help to perform tasks efficiently. Robotic hip exoskeletons can support ambulatory functions in the elderly and augment human performance in healthy people during normal walking and loaded walking by providing assistive torque. In this review, the current development of robotic hip exoskeletons is presented. In addition, the framework of actuation joints and the high-level control strategy (including the sensors and data collection, the way to recognize gait phase, the algorithms to generate the assist torque) are described. The exoskeleton prototypes proposed by researchers in recent years are organized to benefit the related fields realizing the limitations of the available robotic hip exoskeletons, therefore, this work tends to be an influential factor with a better understanding of the development and state-of-the-art technology.

Type
Review Article
Creative Commons
Creative Common License - CCCreative Common License - BYCreative Common License - NCCreative Common License - ND
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (http://creativecommons.org/licenses/by-nc-nd/4.0), which permits non-commercial re-use, distribution, and reproduction in any medium, provided that no alterations are made and the original article is properly cited. The written permission of Cambridge University Press must be obtained prior to any commercial use and/or adaptation of the article.
Copyright
© The Author(s), 2022. Published by Cambridge University Press

Introduction

Robotic exoskeletons can be mainly divided into the medical type and nonmedical type according to their applications. Medical type exoskeleton is used for patients with upper (Yan and Yang, Reference Yan and Yang2014; Chen et al., Reference Chen, Casas and Lum2019; Gandolla et al., Reference Gandolla, Dalla Gasperina, Longatelli, Manti, Aquilante, D’Angelo, Biffi, Diella, Molteni, Rossini, Gfohler, Puchinger, Bocciolone, Braghin and Pedrocchi2021) or lower body disabilities (Yang et al., Reference Yang, Yang and Xu2016; Hwang et al., Reference Hwang, Sun, Han and Wan-Soo2021; Zhu et al., Reference Zhu, Kern, Fowkes, Afzal, Contreras-Vidal, Francisco and Chang2021). With this kind of exoskeleton, some patients can regain the ability of locomotion (Farris et al., Reference Farris, Quintero, Murray, Ha, Hartigan and Goldfarb2014), while some other patients can achieve therapeutic movement and speed up rehabilitation progress (Wang et al., Reference Wang, Yang, Yang, Deng, Ma and Wei2019; Yang et al., Reference Yang, Zhang, Zhang and Yang2020). Nowadays, the nonmedical type exoskeleton is widely researched for its potential in both industries (Chang et al., Reference Chang, Pesek, Pote, Hull, Geissinger, Simon, Alemi and Asbeck2020; Iranzo et al., Reference Iranzo, Piedrabuena, Iordanov, Martinez-Iranzo and Belda-Lois2020; Lazzaroni et al., Reference Lazzaroni, Tabasi, Toxiri, Caldwell, Momi, van Dijk, de Looze, Kingma, van Dieën and Ortiz2020) and the military (Hong et al., Reference Hong, Kim and Yoon2019). With this kind of exoskeleton, part of the human body’s limbs can be augmented. Thus, metabolic expenditure will be reduced during walking, running, lifting, or some other physical labor scenarios versus the cases without the exoskeleton. For further strength enhancement, various exoskeleton structures across different high-level control strategies are designed and tested, which arises great attention toward the research of energy economy in exoskeleton.

For walking assist, single, part or full of hip flexion/extension, knee flexion/extension, and ankle dorsi-flexion/plantar-flexion in the sagittal plane are selected as driven joints. Franks et al. (Reference Franks, Bryan, Martin, Reyes, Lakmazaheri and Collins2021) carried out experiments using a hip–knee–ankle exoskeleton emulator paired with human-in-the-loop optimization to find assistance for different joints that maximally reduced the metabolic cost of walking. They found that hip-only and ankle-only assistance separately reduced the metabolic cost of walking by 26 and 30% relative to walking with the device unassisted while knee-only assistance reduced the metabolic cost of walking by 13%, which confirms that both hip joint and ankle joint are good targets for assistance. For their high energy efficiency, hip exoskeleton and ankle exoskeleton are mostly researched. In this review, we thoroughly summarize and organize walking-assist hip exoskeleton research for a better understanding of the development and state-of-the-art technology.

The frame of this review is shown in Figure 1. In our opinion, a walking-assist hip exoskeleton could be divided into mechanical structure, framework of the actuation joints, high-level control methods, and low-level control methods. Low-level control mainly refers to the output torque control, which is the solid basis for high-level decision-making blocks. Nevertheless, low-level control methods have been investigated with an enormous amount of work in the past time. In this review, the hip exoskeleton is thoroughly studied and discussed from two aspects, the framework of the actuation joints and the control strategies.

Figure 1. Frame of this review. AO, adaptive oscillator; Electromyogram (EMG), electromyogram, FSM, finite state machine; HIL, human-in-the-loop optimization; IMU, inertial measurement unit; NN, neuro network-based gait phase estimation; PO, phase oscillator; SEA, series elastic actuator; TBE, time-based estimation.

The Framework of Actuation Joints

According to external power consumption, the hip exoskeleton can be divided into active exoskeleton and passive exoskeleton. The active one uses a wide variety of actuators, including motors, pneumatics, hydraulics, and so forth. The pneumatic actuator is usually connected directly to the exoskeleton thigh link and controls the movement of the exoskeleton hip joint through its expansion and contraction. The motor generally transfers the torque to the corresponding actuator through some transmission mechanics. For motor-driven actuators, the way of force/torque transmission has a great impact on the control of the hip exoskeleton. The transmission mechanics can be divided into rigid actuators and flexible actuators such as Bowden cable-based actuators, serial elastic actuators (SEAs), and so on. Passive exoskeletons generally recycle the negative mechanical energy generated during certain gait phases and use this energy to assist walking during another part of gait phases, thus improving the energy expenditure efficiency during walking. The typical prototypes of robotic hip exoskeletons with active or passive actuation joints are shown in Figure 2.

Active Hip Exoskeleton

Active hip exoskeletons can assist the wearer to break through some limitations and complete a wider variety of tasks with external energy. The biggest difference between the active exoskeleton ton and the passive exoskeleton is the existence of an external power source. For the active hip exoskeleton, the actuation joint is dominant since it determines mechanism architecture and corresponding functionality. In this review, actuation joints of the active hip exoskeleton are divided into four categories: motor with gear reducer, motor with Bowden cable, pneumatic actuator, and SEA. These alternative actuators and power transmission mechanisms are described in the following subsections.

Motor with gear reducer

Most hip exoskeletons actuation joints are designed with motors and reducers. Both left and right actuation joints are mounted near the wearer’s left and right hip joints and their rotation axes are in alignment with those of the wearer’s hip joints (Wu et al., Reference Wu, Wang, Du and Zhang2015; Lee et al., Reference Lee, Lee, Chang, Seo, Shim, Choi, Ryu and Kim2017c, Reference Lee, Lee, Seo, Lee, Chang, Choi, Ryu and Kim2019; Sugar et al., Reference Sugar, Fernandez, Kinney, Hollander, Redkar, González-Vargas, Ibáñez, Contreras-Vidal, van der Kooij and Pons2017). With excellent performance of low-level motor position control or torque control, precise assist torque generation is guaranteed. Besides, the compact motor and reducer modular design makes the whole system lighter.

Seo et al. (Reference Seo, Hyung, Choi, Lee and Shim2015) developed the device to assist the walking of the elderly with weak muscles. This exoskeleton driven by electrical motors could produce 10 Nm torque nominally. Lee et al. (Reference Lee, Lee, Chang, Seo, Shim, Choi, Ryu and Kim2017c) designed the GEMS to deliver assistive torque to the hip joints for extension and flexion, which is generated by two BLDC motors and transmitted to the hip joint through a 75:1 multistage gear system. Sugar et al. (Reference Sugar, Fernandez, Kinney, Hollander, Redkar, González-Vargas, Ibáñez, Contreras-Vidal, van der Kooij and Pons2017) designed HeSA driven by two motors with gear reducers to assist hip flexion and extension.

Most hip exoskeletons actuated by motors with reducers are rigid types. Some typical hip exoskeletons of this kind are shown in Figure 2a. However, it should be noted that due to the direct connection of motor and reducer actuation characteristics, compliance control needs to be considered to ensure safety and better human–machine interaction.

Motor with Bowden cable

To make the hip exoskeleton actuation joint soft or flexible, a new actuator is developed, which consists of a motor and Bowden cable. Bowden cable is covered with a cable sleeve and winded by a pulley, which is connected to the motor output shaft (Veneman et al., Reference Veneman, Ekkelenkamp, Kruidhof, van der Helm and van der Kooij2005). Thus, the rotation motion of the motor is converted to linear motion. Since the Bowden cable is flexible, it can be aligned with the human body better than rigid actuation joints. However, the hysteresis and nonlinearity characteristics of this flexible actuator make a low-level position or torque control with higher difficulty.

Most Bowden cable-driven exoskeletons are tethered type, with the motors and accessories mounted on the base. Veneman et al. (Reference Veneman, Ekkelenkamp, Kruidhof, van der Helm and van der Kooij2006) developed a series elastic and Bowden cable-based actuation system, which is applied to a lower limb exoskeleton. A series elastic element is designed with low-level force feedback control. Totally, 11 and 20 Hz bandwidths for the full and small force ranges respectively are realized with this actuation system. Collins designed several prototypes with a tethered-type exoskeleton for walking assistance. With Bowden cables, not only single hip, knee, and ankle joints in the sagittal plane can be actuated (Galle et al., Reference Galle, Malcolm, Collins and De Clercq2017; Zhang et al., Reference Zhang, Fiers, Witte, Jackson, Poggensee, Atkeson and Collins2017; Witte et al., Reference Witte, Fiers, Sheets-Singer and Collins2020), but also full lower limbs in the sagittal plane (Bryan et al., Reference Bryan, Franks, Klein, Peuchen and Collins2021) or hip joint motions in both sagittal and frontal planes (Chiu et al., Reference Chiu, Raitor and Collins2021) are driven with torque control. Each direction of actuation is designed with a closed-loop torque bandwidth of at least 18 Hz. To optimize real-time torque tracking performance, Zhang and Collins (Reference Zhang and Collins2021) developed feed-forward iterative learning, which is applied to feedback control. Through theoretical analysis, an optimal iterative-learning gain is predicted as the inverse of the passive actuator stiffness, and walking experiments prove this hypothesis. Walsh reports their research on reducing the metabolic cost of running with a tethered soft exosuit which is also driven by a motor with Bowden cable (Lee et al., Reference Lee, Kim, Panizzolo, Zhou, Baker, Galiana, Malcolm and Walsh2017b). Furthermore, they designed a portable exosuit to reduce the metabolic cost during walking and running (Kim et al., Reference Kim, Lee, Heimgartner, Arumukhom Revi, Karavas, Nathanson, Galiana, Eckert-Erdheim, Murphy, Perry, Menard, Choe, Malcolm and Walsh2019). The compact motors are mounted on the backpack and Bodwen cables are attached through the human waist and lower limbs. Yu et al. (Reference Yu, Huang, Wang, Lynn, Sayd, Silivanov, Park, Tian and Su2019) proposed a soft exoskeleton composed of Bowden cable and quasi-direct drive (QDD) actuation, which produces high backdrivablity.

With soft and flexible actuators consisting of motors and Bowden cables, the walking assist exoskeleton is more like a suit rather than a rigid robot. The advantages of the actuators with Bowden cables are lightweight, high torque, and high degree controllability (Thalman and Artemiadis, Reference Thalman and Artemiadis2020). This actuation joint architecture provides a new promising solution for compliant human–machine physical interaction.

Pneumatic actuator

The pneumatic actuator itself is compliant and lightweight. However, the pneumatic accessories such as air pumps are heavy, therefore, the pneumatic accessories are usually mounted on a fixed base to make the pneumatic actuated hip exoskeleton system lightweight. In this way, the portability of the pneumatic exoskeleton is limited. Similar to Bowden cable transmission actuators, another drawback of the pneumatic actuators is the nonlinearity characteristics. The relationship between the torque generated by pneumatic muscles and the pressure applied in the working process is always nonlinear, which increases the difficulty of low-level torque feedback control (Shiraishi and Watanabe, Reference Shiraishi and Watanabe1996; Sridar et al., Reference Sridar, Poddar, Tong, Polygerinos and Zhang2020). Kawamura et al. (Reference Kawamura, Takanaka, Nakamura and Osumi2013) made an orthosis for hip flexion assistance based on the application of the straight-fiber pneumatic artificial muscle and evaluated the performance of the orthosis by measuring the sEMG signal of the lower limb. Thakur et al. (Reference Thakur, Ogawa, Tsuji and Kurita2018) developed a lightweight (total weight is only 1.217 kg) and wearable Augment Walking Suit using pneumatic gel muscles and tested the assumption that the device can assist walking based on the sEMG signal. Young and Ferris (Reference Young, Foss, Gannon and Ferris2017a) developed a pneumatic hip exoskeleton that assists with both flexion and extension during walking. Bidirectional piston-cylinder pneumatic actuators on each leg assist hip flexion and extension, and are tethered to an external air tank. Biological torque control is applied to the pneumatic hip exoskeleton based on proportional electromyography control, which is proved to have more advantages (metabolic cost and muscle activity reduction) compared to a controller that targeted a biological torque profile (Young et al., Reference Young, Gannon and Ferris2017b). In addition to assisting hip joints, several pneumatic actuator-driven exoskeletons have been developed to assist the ankle joints and knee joints during walking or running (Carberry et al., Reference Carberry, Hinchly, Buckerfield, Tayler, Burton, Madgwick and Vaidyanathan2011; Park et al., Reference Park, Chen, Pérez-Arancibia, Young, Stirling, Wood, Goldfield and Nagpal2014; Sridar et al., Reference Sridar, Nguyen, Zhu, Lam and Polygerinos2017).

The lightweight structure and high power density are the biggest advantages of the pneumatic actuator, on the condition that the pneumatic accessories are mounted on a fixed base. The primary disadvantage is that they are highly underdamped, which makes them the poor choices for position control tasks (Ferris and Lewis, Reference Ferris and Lewis2009). Besides, the need for external drive accessories limits the use of pneumatic muscles.

Serial elastic actuator

Unlike rigid actuators, SEAs are designed by introducing an elastic element between the load and motor with reducers. With the serial elastic element, the inertia and nonlinear frictions of the motor and transmission are decoupled from the load. Meanwhile, external disturbances and shocks are also isolated from the gear transmission (Vallery et al., Reference Vallery, Veneman, van Asseldonk, Ekkelenkamp, Buss and van Der Kooij2008). Pratt and Williamson, (Reference Pratt and Williamson1995) firstly reported the design of SEA, which consists of a motor, a reducer, linear springs, and a displacement sensor measuring the deflection of the spring. Based on Hook’s law, the SEA force output is calculated with sensored displacement. Li et al. (Reference Li, Yuan, Tang, Mao, Zhang, Huang and Tan2018) developed adaptive human–robot interaction control by SEA, which provides either robot-in-charge or human-in-charge mode (Zelik et al., Reference Zelik, Huang T-W, Adamczyk and Kuo2014). Zhang et al. (Reference Zhang, Tran, Huang, Bicchi and Okamura2017) designed an SEA-driven hip exoskeleton and proposed an admittance-based control method, which was experimentally verified to help patients with muscle weakness to walk normally. Kang et al. (Reference Kang, Hsu and Young2018) designed a hip exoskeleton driven by SEA with high-fidelity closed-loop torque control using ball screw transmissions and fiberglass leaf springs.

SEA provides a solution for physical compliance to ensure soft human–machine force interaction. However, the SEA restrains the devices with a narrow bandwidth and limited stiffness. Additionally, the bulkiness of SEA also limits its application. Thus, the selection of elastic elements with a certain stiffness to match human joints’ impedance is the core of SEA driven exoskeleton.

QDD actuator

QDD actuator composed of high torque motors and low gear ratio transmission is a promising solution for wearable robots actuation. On one hand, a portable hip exoskeleton is quite sensitive to its own weight. The compact QDD actuator design is relatively lightweight. On the other hand, the QDD design concept meets the underlying philosophy of “design for control,” namely meticulous robot design can simplify control algorithms while ensuring high performance (Yu et al., Reference Yu, Huang, Yang, Jiao, Yang, Chen, Yi and Su2020). Lv et al. (Reference Lv, Zhu and Gregg2018) presented the design philosophy of a highly backdrivable exoskeleton with torque-dense motors (7.2 Nm peak torque) and low-ratio transmissions (24:1). To balance the joint output torque and velocity requirements, the QDD actuator was designed to provide 30 Nm continuous torque output with peak velocity at 80 RPM. The backdrive torque during static and dynamic conditions are 1.5 and 3 Nm, respectively, and the torque bandwidth is 10 Hz, which exceeds the required bandwidth for human walking (4–8 Hz). Nesler et al. (Reference Nesler, Thomas, Divekar, Rouse and Gregg2022) introduced the design of a Modular Backdrivable Lower-limb Unloading Exoskeleton (M-BLUE), which implements high torque, and low mechanical impedance actuators. The AK80-9 actuator was selected for its high torque density and low gear ratio (9:1). The static and dynamic backdrive torques were measured under 0.5 and 2 Nm, respectively. The benchtop tests verified the low mechanical impedance of the QDD actuator and the accuracy of open-loop current control. Yu et al. (Reference Yu, Huang, Yang, Jiao, Yang, Chen, Yi and Su2020) designed a high-performance QDD actuator-based hip exoskeleton that demonstrates mechanical versatility for being highly backdrivable (0.4 Nm backdrive torque) with high rated torque (17.5 Nm) and high control bandwidth (62.4 Hz). This customized QDD actuator has the potential to ensure fluid human motion, handle rapid or unexpected human movements, and enhance the metabolic expenditure.

QDD actuators use high-torque motors to achieve high output torques with low gear ratios (and thus low friction/inertia). They are promising hip exoskeleton joint actuation solutions to perform dynamic walking, running, and squatting assistance with high control bandwidth, precise current-based torque control, compliance to impacts, and reduced acoustic noise.

Passive Hip Exoskeleton

The passive exoskeleton collects and stores the energy of the human body during periodic walking through the elastic elements, and releases the energy at a certain stage to help the human body complete the next stage of action and realize the power of the whole moving process. Since level walking with steady speed requires no power input, in theory, unpowered walking assistance is practicable, which is validated by simulation models with spring-loaded legs (Zelik et al., Reference Zelik, Huang T-W, Adamczyk and Kuo2014). Initially, most researchers focused on the ankle joint (Collins et al., Reference Collins, Wiggin and Sawicki2015; Li et al., Reference Li, Yuan, Tang, Mao, Zhang, Huang and Tan2018), for its relatively small range of motion which benefits elastic element mounting and makes energy acquisition and release simpler.

In recent years, the passive exoskeleton acting on the hip joint has been gradually developed. Haufe et al. (Reference Haufe, Wolf, Riener and Grimmer2020) studied the influence of the spring installed in front of the hip joint on human movement when walking at the speed of 0.5–2.1 m/s and concluded that the spring releases energy to help the bending of the hip joint. But there is a corresponding increase in muscle activity associated with ankle plantar flexion before and after the bend. Chen et al. (Reference Chen, Wu, Zhou and Xiong2019) from Xiong’s group fabricated a passive elastic exoskeleton called peEXO that can provide torques to assist hip flexors during walking. They find peEXO of a minor stiffness is beneficial to reduce the muscle activation of hip flexors, especially the iliopsoas. Subsequently, their colleagues, Zhou et al. (Reference Zhou, Xiong, Zhang, Hu, Chen and Huang2021a) designed an unpowered hip exoskeleton that can reduce the metabolic cost of walking and running by adjusting the metabolizable energy of hip flexion, and can reduce the metabolic cost of walking and running by 7.2 and 6.8%, respectively after selecting the appropriate spring stiffness. In the same year, Zhou et al. (Reference Zhou, Xiong, Zhang, Chen and Huang2021b) proposed a passive exoskeleton acting on the hip joint and ankle joint. By recovering the energy of the knee joint at the end of the leg swing to do positive work on the hip joint at the stage of standing posture, energy consumption could be reduced by 8.6% compared with that without wearing the exoskeleton. In 2021, Li’s group developed a passive exoskeleton that strategically removes kinetic energy during the swing phase, leading to a reduction of the metabolic cost of walking by 2.5 ± 0.8% for a healthy male. Meanwhile, the removed energy can be converted into 0.25 ± 0.02 watts of electrical power through the portable exoskeleton system (Shepertycky et al., Reference Shepertycky, Burton, Dickson, Liu and Li2021).

Summary of Actuation Joints

The summary of the actuators of the hip exoskeleton is shown in Figure 2. As a traditional drive mode, a motor with gear reducer has some advantages such as higher torque density that flexible actuators do not have. Therefore, a rigid hip exoskeleton driven by a motor with gear reducer occupies a lot of proportion. QDD actuator is a promising exoskeleton joint actuation solution since it leverages high torque-dense motors with low-ratio transmissions. Its backdrivability and low mechanical impedance simplify the low-level control. Because of the better human-exoskeleton interaction, flexible exoskeletons have attracted the attention of researchers. The flexibility of the SEA is achieved through the structure. Pneumatic muscles have high power density and have many applications in hip exoskeletons. Motor with Bowden cable can more easily transfer toque to where it is needed, which makes it possible to design a soft exosuit.

Control Strategy of Robotic Hip Exoskeleton

During the development of the robotic hip exoskeleton, the control strategy is one of the most fundamental issues (Chen et al., Reference Chen, Zi, Qin and Pan2020). With suitable control approaches, robotic hip exoskeletons can generate the assistive torques as needed for the wearers, and the comfort and safety of the human-exoskeleton system can be guaranteed. In this article, the whole control flow is divided into two stages, the high-level control stage and the low-level control. High-level control is the strategy for how desired assistive torque is generated according to the human–machine-environmental state. At the high level, the robotic hip exoskeleton estimates the gait phase and then generates the desired torque by the data collected by the sensor system to deal with the question of when and how to provide assist torque to human body. The low-level controller mainly ensures the desired torque received from the high-level controller is accurately output.

Low-Level Control

Most of the low-level control methods are not limited to an exoskeleton but rather shared between many robotic applications. Besides, where those methods are used will not affect the desired behaviors such as tracking of reference input accurately and stably. Therefore, there are only a few papers that focused mostly on low-level control for exoskeletons. In this review, according to whether there is feedback, the low-level control is divided into open-loop control and closed-loop control, and both are outlined separately.

Open-loop control

For open-loop control, the actual torque received by the human body is not measured through force or torque sensors as feedback signals. Instead, stable and accurate torque output is achieved through friction, damping force, and inertia force compensation, which are identificated and modeled offline (Ikeuchi, Reference Ikeuchi2007). Seo et al. (Reference Seo, Lee, Lee, Ha and Shim2016) compensate the friction and the inertial force in order to deliver the assist torque as intended without measuring the force delivered to the users. In our previous work, a parameter was added to the motor controller for friction compensation to make sure that the output torque and the target torque are as consistent as possible (Yang et al., Reference Yang, Xu, Yu, Chen, Yan and Yang2021).

The reason why researchers chose open-loop control is that it requires no extra sensors and structures, which makes the hardware simpler (Baud et al., Reference Baud, Manzoori, Ijspeert and Bouri2021). However, it is difficult to compensate for the friction completely because of its complex modeling.

Closed-loop control

Unlike the open loop control, closed-loop control requires a torque sensor or force sensor for feedback signal measurement. For low-level closed-loop control, how to achieve stable and accurate control performance attracts researchers’ attention.

Yu et al. (Reference Yu, Huang, Yang, Jiao, Yang, Chen, Yi and Su2020) proposed a simplified low-level feedback torque control thanks to the design of QDD actuator. The control architecture is composed of an inner-loop current control and outer-loop torque control. The feedback signal of the outer-loop is from motors, load cells, and IMU-based gait detection. Experiments indicate that the low-level control is able to produce high bandwidth (62.4 Hz) and high control accuracy (1.09 Nm RMS tracking error, 5.4% of the desired peak torque). Xue et al. (Reference Xue, Wang, Zhang and Zhang2019) proposed a direct force controller to achieve ideal force tracking performance and further guarantee flexible and natural walking assistance. The feedback signal of the direct force controller comes from the torque sensor. The bandwidth is calculated as 61.4 Hz from the bodegraph, which is sufficient for gait assistance. The fact that the actual torque is capable to track a desired reference with a maximum tracking error of 1.5 Nm has been proved by experiments. Oh and Kong (Reference Oh and Kong2017) proposed that the force control performance of the SEA can be improved by exploiting the dynamic model of the SEA. And then an SEA trajectory-tracking control method was used to control the exoskeleton (Zhang et al., Reference Zhang, Tran and Huang2019a). Subsequently, they proposed a new torque control, based on the singular perturbation integrated with flexibility compensation for SEA to better control the designed SEA with a clutch for the hip exoskeleton. It can effectively control actuation timing and allow precise assistive torque control (Zhang and Xia, Reference Zhang and Xia2019b). Zhang et al. (Reference Zhang, Cheah and Collins2015) identified a model-free, integral-action-free feedback control compensated by iterative learning as the most effective controller for lower-limb exoskeletons torque tracking during walking. With time-based desired torque, root-mean-squared errors were 0.6 Nm (1.3% of peak desired torque) step by step, and 0.1 Nm (0.2%) on average. They designed, developed, and compared the torque-tracking performance of nine control methods and then tested each control method with four high-level controllers that generate desired torque.

Compared with the open-loop control, the close-loop control is a more classical way for accurate torque tracking, which requires a torque sensor or force sensor for feedback signal measurement. In the meantime, closed-loop control also requires better algorithms and compact mechanical design.

High-Level Control Strategy

A high-level control strategy can firstly be divided into three parts: data collection, gait phase estimation, and assistive torque generation. For the data collection part, gait information is sampled by sensors installed on the hip exoskeleton during walking. With the gait information, the gait phase is estimated which divides continuous walking into several gait cycles and quantifies the period of current state during each gait cycle, thus the gait phase ratio is obtained. Assistive torque is finally generated based on the gait phase ratio during each gait cycle and human–machine interaction performance as well.

Data collection

According to the type of data sources, sensors can be divided into physiological sensors and physical sensors. Physical sensors are mainly used for detecting the body’s physical data, such as inertial measurement unit (IMU) used to detect the joint angular velocity (Ding et al., Reference Ding, Galiana, Siviy, Panizzolo and Walsh2016; Lee et al., Reference Lee, Lee, Chang, Seo, Shim, Choi, Ryu and Kim2017c; Seo et al., Reference Seo, Kim, Park, Cho, Lee, Choi, Lim, Lee and Shim2018; Steijlen et al., Reference Steijlen, Burgers, Wilmes, Bastemeijer, Bastiaansen, French, Bossche and Jansen2021), force-sensitive resistor (FSR) used to measure human plantar pressure or human–machine interaction force (Pappas et al., Reference Pappas, Popovic, Keller, Dietz and Morari2001; Kong and Tomizuka, Reference Kong and Tomizuka2009; Sanz-Merodio et al., Reference Sanz-Merodio, Cestari, Arevalo, Carrillo and Garcia2014). Physiological sensors mainly collect human body physiological signals to achieve no time-delay control, such as surface electromyogram (sEMG) sensor to collect weak electrical signal of muscle surface that represents muscle strength (He and Kiguchi, Reference He and Kiguchi2007; Zhang et al., Reference Zhang, Fiers, Witte, Jackson, Poggensee, Atkeson and Collins2017), capacitive sensor to measure muscle strength (Zheng et al., Reference Zheng, Wang, Wei and Wang2014, Reference Zhang, Fiers, Witte, Jackson, Poggensee, Atkeson and Collins2017; Zheng and Wang Reference Zheng and Wang2017), metabolic consumption detection equipment that used to measure the energy expenditure of the human body (Panizzolo et al., Reference Panizzolo, Freisinger, Karavas, Eckert-Erdheim, Siviy, Long, Zifchock, LaFiandra and Walsh2019), and so on. In this section, we will introduce these sensors and their applications in the hip exoskeleton.

Physical signal

Force sensors: The force sensor mounted at the heel detects the contact between the heel and the ground to recognize the heel strike gait event. Thus the continuous walking gaits can be divided into repeated gait cycles. Force sensors can also be applied to measure plantar force distributions (Yang et al., Reference Yang, Zhang, Zhang and Yang2020) and calculate the stability margin of the human–machine system during walking. In this application, several FSR sensors are distributed in the shoes.

Pappas et al. (Reference Pappas, Popovic, Keller, Dietz and Morari2001) designed a real-time gait stages detecting system that recognizes standing, heel leaving, swinging, and heel strike, using three FSRs in the soles and a gyroscope on the foot. In their experiments, the gait phase detection delay is less than 90 ms, and the accuracy of the walking state recognition (upstairs and downstairs) is over 96%. Kong and Tomizuka (Reference Kong and Tomizuka2009) used an air force sensor to measure ground contact forces and designed an algorithm that can detect the gait phase smoothly and continuously. A high-level algorithm for detecting the abnormal gait phase is also proposed, which applies a fuzzy logic algorithm to detect the gait phase of each foot to achieve abnormal gait detection. Kang et al. (Reference Kang, Hsu and Young2018) placed a force-sensitive resistor at each heel to detect the beginning of a gait cycle. Yan et al. (Reference Yan, Parri, Ruiz Garate, Cempini, Ronsse and Vitiello2017) divided the gait by sensitive plantar pressure insoles. Song and Collins (Reference Song and Collins2021) used a force sensor placed at the heel to detect heel-strike events. We developed an 8 × 8 FSR array-based shoes for gait event detection and children’s pathological gait identification as well (Xu et al., Reference Xu, Chen, Wang, Chen, Yang and Yang2021). The advantage of using the plantar pressure sensor to detect the segmentation point of gait is that it is simple and accurate. Nevertheless, during multimodal walking scenarios, it is difficult to perform continuous gait estimation using plantar pressure sensors, in which case, plantar pressure sensors are usually used as data inputs for the time-based gait partitioning method. The force sensor is usually composed of a load sensor and a force-sensitive resistor, and its service life is limited due to repeated loads (Menguc et al., Reference Menguc, Park, Martinez-Villalpando, Aubin, Zisook, Stirling, Wood and Walsh2013). The limited service life reduces the reliability of the system in long-term use.

Inertial measurement unit: IMU can measure the acceleration of the lower limbs during exercise, the swing angular velocity and angle of the foot, and other stable and repeatable gait information during exercise. Compared with the force sensor, the gait information of IMU is more continuous and smooth. At the same time, compared with the EMG signal, IMU, as a physical signal, is not directly connected with the user’s skin or flesh and is not affected by the user’s physiological state. IMU is usually used in combination with force sensors to improve the accuracy of detection. At the same time, due to the small size of the IMU, it can be easily embedded in various devices.

The compact and portable IMU sensor can be embedded in the waist, thigh, shank, or foot of either the human body or exoskeleton to measure the kinematic information of each part. Seo et al. (Reference Seo, Kim, Park, Cho, Lee, Choi, Lim, Lee and Shim2018) obtained the posture of the lower limb exoskeleton with IMU sensors installed on the backpack, shank, and foot. Thus the hip flexion/extension angle, abduction/adduction angle, and knee flexion/extension angle could be calculated. With the kinematic data, they innovatively divide the walking scenarios into the flat ground, upstairs/downstairs, and up/down slopes. The experiments show a classification accuracy of 100% (Weigand et al., Reference Weigand, Zeiss, Grimmer and Konigorski2020). Hu et al. (Reference Hu, Krausz and Hargrove2018) presented a use of IMU and depth sensors fixed on the thigh to detect gait data and perform gait segmentation with accuracy approaching that of a setup with bilateral thigh and shank IMUs. Ding et al. (Reference Ding, Galiana, Siviy, Panizzolo and Walsh2016) proposed an iterative hip joint torque controller based on an IMU sensor, which can provide a predefined auxiliary contour to assist hip joint extension. The controller is implemented on a single-joint soft jacket coupled with a multijoint driving platform. The platform can quickly reconfigure different sensors and implement control strategies to generate assist torque. However, the shortcomings of IMU are also obvious. The sampled data drift will affect the consistency of the measured results. To compensate for data drift, additional calculations and more sensors must be used, which increases the complexity of the entire system, and the performance of the system will also be affected by violent movement (Tucker et al., Reference Tucker, Olivier, Pagel, Bleuler, Bouri, Lambercy, Millán J del, Riener, Vallery and Gassert2015).

Encoder: The encoder is one of the most applied sensors in the exoskeleton. In a large number of researches, the encoder is integrated into the motor to measure the rotation angle of the motor so that the motor can be controlled more accurately.

Some researchers also use the encoder to measure the joint angle of the exoskeleton. Bryan et al. (Reference Bryan, Franks, Klein, Peuchen and Collins2021) use an encoder to measure the joint angle of the hip, knee, and ankle of the exoskeleton. Giovacchini et al. (Reference Giovacchini, Vannetti, Fantozzi, Cempini, Cortese, Parri, Yan, Lefeber and Vitiello2015) set up two encoders in each actuation unit. An incremental encoder was built into the motor to measure the angle of the motor to control the motor. An absolute encoder was mounted on the axis collocated with the human hip flexion–extension axis to indirectly measure the absolute hip joint angle. Quinlivan et al. (Reference Quinlivan, Lee, Malcolm, Rossi, Grimmer, Siviy, Karavas, Wagner, Asbeck, Galiana and Walsh2017) used a motor encoder to collect the Bowden cable position.

The advantage of the encoder is that it can measure the angle precisely. Nevertheless, encoders have high requirements for installation accuracy, it is difficult to completely align the human body with external joints. Therefore, encoders are usually used to measure the angle of the exoskeleton for feedback or to measure the rotation angle of the motor for low-level control rather than measure the angle of human joints.

Physiological signal

EMG sensors: EMG signals are important information for the robot system to understand how the user intends to move (Kiguchi et al., Reference Kiguchi, Tanaka and Fukuda2004, Reference Kiguchi, Esaki and Fukuda2005; Kiguchi, Reference Kiguchi2007). Compared with other sensors, the EMG sensor can detect the muscle electrical signal which directly reflects the user’s movement intention. He and Kiguchi (Reference He and Kiguchi2007) proposed an EMG-based control for the exoskeleton. They installed six electrodes on the front of the thigh and two electrodes on the back of the thigh to detect the EMG signal as the input of the controller using a fuzzy neural control method. Meanwhile, EMG sensors are used to show that the user’s muscle activation decreased with the help of the exoskeleton. Grazi et al. (Reference Grazi, Crea, Parri, Lova, Micera and Vitiello2018) proposed a new EMG-based assistive control strategy for lower-limb exoskeletons. They experimentally demonstrated that the assistive method based on the integration of a gait phase estimator and an EMG proportional controller can reduce the activation peak of the muscles involved in the forward movement.

However, surface electromyography electrodes must be firmly attached to the skin around the target muscle. The displacement of electrodes and the presence of sweaty skin have a negative impact on the performance of motion recognition (Sawicki et al., Reference Sawicki, Gordon and Ferris2005). The EMG signal is weak and susceptible to external noise, so a dedicated onboard circuit is required for signal preprocessing. Due to the weakness of the electrical sensor signal, using sEMG signal as a control parameter directly has high requirements on the hardware system and control algorithm.

Another issue we need to focus on about EMG sensors is the selection of muscle. Researchers have focused on the muscles of the lower extremities used for walking, among which the rectus femoris and gastrocnemius are believed to play a major role in walking. Both two muscles have been selected in many studies, while some other muscles have been selected as example.

As a physiological signal, EMG can show the state of the user wearing the exoskeleton more intuitively than physical sensors. Therefore, EMG signals are increasingly used in the evaluation and control of exoskeleton, even though there are some disadvantages as mentioned above. Some other feature extraction methods of EMG signals have also been concerned by researchers.

Capacitive sensor: A capacitive sensing system is a noncontact wearable sensor. The capacitive sensor (C-Sens) is designed with two sensing cuffs to measure the muscle shape change during walking. The capacitance electrodes adhered to the inner surface of the sensing cuff form the equivalent capacitor with the human body. The contraction and extension of muscles during walking will cause a change of capacitance. By analyzing the change in capacitance, the user’s current motion intention and walking state can be detected (Zheng et al., Reference Zheng, Wang, Wei and Wang2014). Zheng et al. (Reference Zheng, Manca, Yan, Parri, Vitiello and Wang2017) proposed a noncontact capacitive sensor system for amputees, which can judge the user’s motion mode with high precision. In subsequent studies, Zheng and Wang (Reference Zheng and Wang2017) placed capacitors on the thigh and calf, and continuous gait phase estimation with good real-time performance is obtained through adaptive oscillators (AOs), and the stability of the phase estimation system based on wearable capacitive sensors is also proved. In their experiment, a single-channel capacitance signal was used to achieve accurate and consistent gait phase estimation. Crea et al. (Reference Crea, Manca, Parri, Zheng, Mai, Lova, Vitiello and Wang2019) presented a hip exoskeleton that was controlled using capacitive sensors placed in orthopedic cuffs on the shanks. Experiments show that the controller can estimate the gait phase with an average error of 4%.

Metabolic consumption sensors: The ultimate goal of most walking-assist exoskeletons is to improve the effort of a human during walking. In this case, energy expenditure, as an objective measure of effort that can be detected, is a gold standard for evaluating the walking-assist exoskeleton (Beneke and Meyer, Reference Beneke and Meyer1997; Sawicki et al., Reference Sawicki, Beck, Kang and Young2020). In addition, the metabolic cost is related to overall performance in a given mode (Hoogkamer et al., Reference Hoogkamer, Kipp, Spiering and Kram2016).

Many researchers use metabolic cost to characterize the performance of designed hip exoskeletons, as shown in Figure 3. Seo et al. (Reference Seo, Lee, Lee, Ha and Shim2016) designed a hip exoskeleton GEMS which showed a 13% reduction in energy consumption compared to no exoskeleton. On this basis, Lim et al. (Reference Lim, Lee, Jang, Kim, Park, Seo and Shim2019) updated the structure of GEMS to make it lighter and used a new algorithm that significantly reduced the subjects’ energy consumption from 16.6 to 24% through metabolic cost tests, and proved that the performance of the exoskeleton was optimized. Ding et al. (Reference Ding, Kim, Kuindersma and Walsh2018) tested the effect of their exosuit by metabolic rate and found that with the assistance of the exosuit, the metabolic rate was reduced by 17.4 ± 3.2% compared with normal walking.

Figure 3. Robotic hip exoskeleton with the index of metabolic cost reduction and selection of muscles for sEMG detection. BF, biceps femoris; GM, gluteus maximus; RF, rectus femoris; ST, semitendinosus; SOL, soleus; TA, tibialis anterior; VL, vastus lateralis; VM, vastus medialis.

Measuring energy consumption requires specialized and complex equipment and takes a long time to collect results, which means that it is difficult to use the metabolic cost as a feedback control signal for the exoskeleton. In most cases, the metabolic cost is used as an indicator to determine whether the exoskeleton can assist the user. Some researchers pay attention to generating superior assistance torque profiles by metabolic cost.

Gait phase estimation

Gait is the key kinematic characteristic for describing how a person walks. A human individual varies in anatomical structure, physiological function, motion control ability, and mental state, thus varies in their gaits. In general, the gait changes periodically in the process of walking. Dividing the gait into different stages in each gait cycle can help us extract the features of each stage, and achieve a better gait stage-based exoskeleton control. Gait phase estimation can be divided into discrete gait event classification and continuous gait phase estimation, as shown in Figure 4. Discrete gait event consists of several characterized stages such as heel strike, toe off, support phase, swing phase, and so forth. The finite state machine (FSM) based gait event classification is one of the classical discrete gait event classification methods. Continuous gait phase estimation divides the gait into each cycle and counts the gait phase of each cycle from 0 to 100% continuously. Phase oscillator (PO), adaptive oscillator (AO), time-based estimation (TBE), and neural network based gait phase estimation (NN) are all state-of-the-art continuous gait phase estimation methods.

Figure 4. Gait phase division during walking, which can be divided into discrete one and continuous one. DLS, double leg support; LHR, left heel rise; LHS, left heel strike; LLS, left leg support; LTO, left toe-off; RHR, right heel rise; RHS, right heel strike; RLS, right leg support; RTO, right toe-off.

Finite state machine

In a Gait-Phase Detection Sensor (GPDS) and a programmable Functional Electrical Stimulation (FES) system, the gait phase is extracted by a knowledge-based FSM algorithm, which is used in a finite state control scheme to time the electrical stimulation sequences leading to an improvement in gait-kinematics of the affected leg (Pappas et al., Reference Pappas, Keller, Mangold, Popovic, Dietz and Morari2004; Wang et al., Reference Wang, Wang, van Asseldonk and van der Kooij2013). Similarly, Pappas et al. (Reference Pappas, Popovic, Keller, Dietz and Morari2001) designed a GPDS that consisted of three FSRs in the shoe insole and a gyroscope in the shoe. The GPDS detected accurately and reliably in real-time the four gait events: stance, heel-off, swing, and heel-strike. Walsh et al. (Reference Walsh, Pasch and Herr2006) applied the FSM based on the hip angle and the force in the exoskeleton leg to divide each gait cycle into six discrete gait events, which were used for exoskeleton hip joint control (Figure 5a).

Figure 5. Graphical diagrams of five gait estimation methods. (a) Finite state machine (Walsh et al., Reference Walsh, Pasch and Herr2006), (b) Adaptive oscillator (Lenzi et al., Reference Lenzi, Carrozza and Agrawal2013), (c) Phase oscillator (Sugar et al., Reference Sugar, Bates, Holgate, Kerestes, Mignolet, New, Ramachandran, Redkar and Wheeler2015), (d) Neural network (Kang et al., Reference Kang, Molinaro, Duggal, Chen, Kunapuli and Young2021), and (e) Time-based estimation (Kang et al., Reference Kang, Hsu and Young2018).

Although everyone’s walking style is not identical, FSM can achieve high detection reliability in tasks involving walking on different terrains and is insensitive to interference caused by nonwalking activities.

Time-based estimation

TBE estimates the gait cycle using FSR mounted under the heel. The current phase inside each gait cycle expressed as a percent of the stride period is acquired as the ratio between the time elapsed from the start of the current cycle and the expected duration of the cycle (Lewis and Ferris, Reference Lewis and Ferris2011; Lenzi et al., Reference Lenzi, Carrozza and Agrawal2013). Figure 5e is a graphical diagram of TBE.

TBE is suitable for highly periodic gaits. In this method, the time of each step is collected to predict the time of subsequent gait cycles. Lewis and Ferris (Reference Lewis and Ferris2011) used the mean time of the first 10 strides to predict the time of the next cycle. Thus the assist torque applied in each gait phase is determined. Kang et al. (Reference Kang, Hsu and Young2018) obtained the time of each gait cycle by FSR and averaged it over the last five strides. The time after the current heel impact is then normalized to the average stride time to estimate the current gait stage. For TBE, the most important parameter is the number of cycles used to estimate the next cycle. The more cycles used to estimate the next cycle, the better the overall estimation effect will be, but the ability to change the response speed will be weak.

TBE can be used to correctly estimate the gait phase for the simple system since the algorithm is quite simple. The disadvantage of this method is that it cannot adapt to rapid changes in speed. It would take several gait cycles to fit the current speed after the change. If there are conscious rapid changes, TBE will not be able to estimate the gait cycle accurately.

Phase oscillator

A phase-based oscillator could help humans perform periodic or repetitive tasks. Kerestes et al. (Reference Kerestes, Sugar and Holgate2015) added a bounded amount of energy to their wearable robots to assist body motion. They take advantage of an anti-phase angle to subtract energy from body motion. De La Fuente et al. (Reference De La Fuente, Subramanian, Sugar and Redkar2020) applied the Lyapunov redesign method to construct a robust controller using a bounding function and produced a bounded control signal to modify the amplitude and frequency of the resulting second-order oscillator, this can modulate stiffness and damping properties

Notice that utilizing resonant energy pumping and adding a tiny amount of energy at an appropriate time can result in an amplified response. Sugar et al decided to add energy at resonance so the system attains the limit cycle based on a PO (Figure 5c). It handles the problem of not clearly defined resonant boundaries (Sugar et al., Reference Sugar, Bates, Holgate, Kerestes, Mignolet, New, Ramachandran, Redkar and Wheeler2015). To optimize oscillator behavior, De la Fuente et al. (Reference De la Fuente, Sugar and Redkar2017) applied a nonlinear oscillator, using a forcing function-based on the sine and cosine of the system’s phase angle, which can modulate the amplitude and frequency of oscillation. The phase oscillator assumes the thigh angle profile and its integral to be sinusoids. However, the angle profile and its integral do not fit the assumption at lower walking speeds. In terms of this issue, Hong et al. (Reference Hong, Anil Kumar and Hur2021) proposed a phase-shifted variable using the user’s thigh information, which can improve linearity and heel-strike detection in the resulting phase variable and enable more accurate gait detection.

With an extra integral signal, the phase oscillator performs well in the mode transition such as changes in walking speed. However, this extra signal causes the phase oscillator to be susceptible to noise, so good filtering is essential for phase oscillators.

Adaptive oscillator

An AO is a system that can lock on to a time-varying input signal, synchronizing its output to both the frequency and phase of the input. It is a mathematical primitive being able to learn the high-level features of a quasi-sinusoidal signal. Given the cycle feature of gait analysis, AO is a natural way of modeling or generating periodic behavior (Buchli et al., Reference Buchli, Ijspeert, Schaal, Billard, Vijayakumar, Hallam and Meyer2004; Ronsse et al., Reference Ronsse, Koopman, Vitiello, Lenzi, De Rossi, Kieboom, van Asseldonk, Carrozza, Kooij and Ijspeert2011a; Yan et al., Reference Yan, Parri, Ruiz Garate, Cempini, Ronsse and Vitiello2017; Xue et al., Reference Xue, Wang, Zhang and Zhang2019).

Ronsse et al. (Reference Ronsse, Vitiello, Lenzi, van den Kieboom, Carrozza and Ijspeert2011b, Reference Ronsse, De Rossi, Vitiello, Lenzi, Koopman, van der Kooij, Carrozza and Ijspeert2012) first applied AO to estimate the user’s intended movement while performing a cyclical motion task such as walking. As shown in Figure 5b, Lenzi et al. (Reference Lenzi, Carrozza and Agrawal2013) proposed an assistive controller which can compute the current stride percent by combining the left foot heel strike detection with the gait cycle estimated through an adaptive frequency oscillator. Seo et al. (Reference Seo, Hyung, Choi, Lee and Shim2015) proposed a new adaptive frequency oscillator called a particularly shaped adaptive oscillator (PSAO) which can estimate the gait cycle without foot contact sensors. The results of the simulation showed that the PSAO-based gait assistance system reduced the metabolic cost in some assistance patterns. In subsequent studies, Seo et al. (Reference Seo, Lee, Lee, Ha and Shim2016, Reference Seo, Kim, Park, Cho, Lee, Choi, Lim, Lee and Shim2018) continuously optimized the PSAO to make it converge faster. Besides, Yan et al. (Reference Yan, Parri, Ruiz Garate, Cempini, Ronsse and Vitiello2017) came up with an AO-based gait phase estimator that could provide consistent and finely tuned assistance for an exoskeleton device to augment the mobility of participants. Grazi et al. (Reference Grazi, Crea, Parri, Lova, Micera and Vitiello2018) estimated the current gait phase in real-time using a pool of AOs. The pressure signals from the shoe insoles help detect the heel strike gait event and reset the gait phase from AOs. The assistive torque of the active pelvis orthosis is then calculated based on the gait phase. Later, Xue et al. (Reference Xue, Wang, Zhang and Zhang2019) proposed a novel gait synchronizer driven by only hip angular velocity.

Optimization of the AO method is progressing continuously. Traditional AO does not always converge or converge slowly when the gait task is switching. Wu et al. (Reference Wu, Ma, Yong, Wang, He and Li2019) adjusted to fine-tuning the AO network. They devised a new gait phase estimator architecture, including a gait tasks classifier, an AO reset, a peak detector, and a transition gait phase estimator. Also, some other researchers presented a two-layered system for learning and encoding a periodic signal without any knowledge of its frequency and waveform, and modulating the learned periodic trajectory in response to external events on a humanoid HOAP-2 robot (Gams et al., Reference Gams, Ijspeert, Schaal and Lenarcic2009). In our previous work, a hybrid oscillator is designed consisting of PO and AO. During cyclic or quasi-cyclic walking, AO is selected for precise gait phase estimation while during noncyclic walking, PO is selected for gait phase estimation (Yang et al., Reference Yang, Xu, Yu, Chen, Yan and Yang2021).

Neuro network

Due to the rising popularity in the neural networking field, lots of scholars start to apply the NN method in gait analysis and boost recognition performance by a large margin. Figure 5d shows a graphical diagram of this method. Susanto et al. (Reference Susanto and Song2016) used data from an experiment with staircases to train artificial neural networks and use the k-Nearest-Neighbor method in a continuous gait phase estimation. This model achieves a mean absolute error of less than 6%, and results in three cases, namely level walking, stair ascent, and stair descent. Seo et al. (Reference Seo, Park, Lee, Hyung, Lee, Kim, Choi and Shim2019) developed a neural network model based on sensor fusion to estimate the gait phase adaptable to dynamic speed in real-time and verified the feasibility of using a machine learning model to accurately estimate the gait phase and improve the controllability of the lower limb exoskeleton. In recent years, Young and his colleagues made remarkable progress in NN-based gait phase estimation for multimodal locomotion (Camargo et al., Reference Camargo, Ramanathan, Flanagan and Young2021; Kang et al., Reference Kang, Molinaro, Duggal, Chen, Kunapuli and Young2021), which is applied to hip exoskeleton (Kang et al., Reference Kang, Molinaro, Choi and Young2020, Reference Kang, Molinaro, Duggal, Chen, Kunapuli and Young2021), knee exoskeleton (Lee et al., Reference Lee, Kang, Molinaro, Yu and Young2021), and ankle exoskeleton (Shafer et al., Reference Shafer, Philius, Nuckols, McCall, Young and Sawicki2021). For hip exoskeleton control, they developed a sensor fusion-based NN model to estimate the continuous gait phase in real-time, which can adapt to variable walking speeds ranging from 0.6 to 1.1 m/s (Kang et al., Reference Kang, Molinaro, Duggal, Chen, Kunapuli and Young2021).

The NN method does not require a phase prediction part, the algorithm processing is simple, and it is promising regarding performance and processing speed for implementation on the hip exoskeleton. However, inside the NN is a black box, which is difficult for experts to debug, or further optimize the effect of the algorithm.

Assist torque generation algorithms

Another important part of the exoskeleton high-level control is the generation of desired assist torque, which determines how much force to output at each gait phase to assist the subject’s hip joint. Much effort has been made to determine the optimal assist torque for better walking assistance. The torque profile generation methods can be divided into the database, function with adjustable parameters, and Human-in-the-loop optimization as shown in Figure 6.

Figure 6. Typical assist torque generation methods. (a) Database with a look-up table (Xue et al., Reference Xue, Wang, Zhang and Zhang2019). (b) Function-based on gait phase and assist torque factor (Yang et al., Reference Yang, Xu, Yu, Chen, Yan and Yang2021). (c,d) Human-in-the-loop optimization (Ding et al., Reference Ding, Kim, Kuindersma and Walsh2018; Chiu et al., Reference Chiu, Raitor and Collins2021).

Database

There are many ready-made databases from biomechanical simulations and experiments on human normal walking. Scaling the biomechanical joint torque profiles, the assist torque database is generated (Figure 7a). Database-based torque generation algorithm is simple and feasible.

Figure 7. Diagrams for various assist torque generation algorithms. (a) Database (Seo et al., Reference Seo, Lee, Lee, Ha and Shim2016). (b,c) Function with adjustable parameters (Lim et al., Reference Lim, Lee, Jang, Kim, Park, Seo and Shim2019; Yang et al., Reference Yang, Xu, Yu, Chen, Yan and Yang2021). (d) Human-in-the-loop optimization (Zhang et al., Reference Zhang, Fiers, Witte, Jackson, Poggensee, Atkeson and Collins2017).

Xue et al. (Reference Xue, Wang, Zhang and Zhang2019)established a database using the human hip joint torque for the power assist of a flexible hip exoskeleton. By measuring the hip angular velocity, the commanded torque profile is modulated with estimated walking states and speed. Lee et al. (Reference Lee, Lee, Chang, Seo, Shim, Choi, Ryu and Kim2017c) mapped the assist torque with the gait cycle according to the biomechanical hip joint torque database. Meanwhile, the subject’s body weight and assist factor will be multiplied as the coefficient, thus the final actuator torque command is acquired.

The database is a simple and intuitive way to generate assist torque, but it also has many shortcomings. The database is generally targeted at the situation of uniform walking, however, the subject will face more complex and diverse scenarios in daily hip exoskeleton assisted walking. It may be difficult to generate assist torque by the database to adapt to changeable external conditions. The other problem with the database-based torque generation algorithm is that the scaled biomechanical joint torque profiles may not be the optimal assist torque.

Function with adjustable parameters

To achieve more optimized control, some researchers proposed the torque generation algorithms determined by function with adjustable parameters. The parameters can be adjusted offline or online to determine the relatively optimal parameters and achieve discrete optimization. Figure 7b,c shows two types of functions to generate assist torque profiles.

The relatively simple parameters are the timing to start the assist torque, the timing to apply the peak torque, and the peak torque value. Ding et al. (Reference Ding, Panizzolo, Siviy, Malcolm, Galiana, Holt and Walsh2016) optimized these parameters and conducted experiments on the following four cases depending on the different parameters, early-start-early-peak, early-start-late-peak, late-start-early-peak, and late-start-late-peak. The highest positive mechanical power delivered by the soft exosuit was reported in the early-start-late-peak condition, which also showed a significant reduction in both biological hip and knee joint power. In addition, relatively complex optimization can also be carried out. Chen et al. (Reference Chen, Guo, Sun, Liu and Jin2021) added parameters to the torque control function. The parameters of the assistive profiles were estimated based on an analysis of biological hip power and then optimized in real-time using the hip angles. The peak and offset timings were determined using the parameters of the previous gait, while the start and stop points were determined from those of the current gait. Finally, it was determined through experiments that with adjustable parameters, the maximum hip joint assist torque could be generated and the relatively optimal walking assist effect could be obtained.

The torque generation algorithm based on function with adjustable parameters is more flexible. The parameters can be tuned to make the exoskeleton adapt to a variety of situations, and the discrete optimal walking assist can also be obtained. The number of parameters should be limited. If there are too many parameters, the workload of determining the optimal parameters will be increased geometrically. The value of the available parameter is also limited, so we can only choose a relatively better one in the experiment, which is a discrete optimization method.

Human-in-the-loop optimization

Researchers put forward the method of determining the parameters by adding the real-time biological signals of the wearer into the control system, which is called human-in-the-loop control. At present, the most commonly used biological signals are metabolic cost and EMG signals, which are mostly used to characterize the reduction of the subject’s effects during exoskeleton-assisted walking.

Zhang et al. (Reference Zhang, Fiers, Witte, Jackson, Poggensee, Atkeson and Collins2017) used metabolic cost as a feedback signal (Figure 7d) to optimize the assist torque profile of the exoskeleton and used the rise time, fall time, peak time, and peak torque to generate a cubic spline curve. Combined with the energy consumption acquisition device, they carried out online continuous optimization and finally reduced the energy consumption by 24.2 ± 7.4% compared to no torque. To solve the delay and noise of the sensor, and to shorten the optimization, many researchers have proposed improved schemes for the human-in-the-loop algorithm. Felt et al. (Reference Felt, Selinger, Donelan and Remy2015) demonstrated Instantaneous Cost Gradient Search method to automatically identify parameters of assistive devices via the optimization of a desired physiological objective. This method enables considerable time savings and readily extends to multidimensional parameter spaces. The subjects’ walking time could be reduced from over an hour to less than 10 min. Based on improving the experimental device designed by Ding et al. (Reference Ding, Kim, Kuindersma and Walsh2018) and Felt et al. (Reference Felt, Selinger, Donelan and Remy2015) proposed a new global parameter optimization algorithm with high noise tolerance, adopted the optimization method of Gaussian process regression to fit the distribution of metabolic expenditure, and optimized the metabolism through Bayesian optimization. Experiments show that the proposed Bayesian optimization algorithm can double the convergence rate of the traditional gradient descent method. In a follow-up study, Ding et al. (Reference Ding, Kim, Kuindersma and Walsh2018) found optimal peak and offset times in an average time of 21.4 ± 1.0 min, resulting in a 17.4 ± 3.2% reduction in metabolic costs compared to walking without instruments.

Human-in-the-loop is an iterative optimization scheme. The parameters of assist torque can be tuned automatically according to the wear’s biological signals. However, some problems still need to be overcome. Since it is impractical to wear the mask all the time for metabolic expenditure measurement, the assist torque profile parameters must be optimized separately before use. Therefore, individual differences will affect the application of human-in-the-loop optimization methods for assist torque generation. In 2021, Walsh’s group developed a muscle-based assistance strategy. The exosuit assistance was derived from direct measurements of wearers’ muscle dynamics using ultrasonographic imaging in real-time. This novel approach enables a relatively rapid (about 10 s) generation of individualized low-force assistance profiles that provide metabolic benefits (Nuckols et al., Reference Nuckols, Lee, Swaminathan, Orzel, Howe and Walsh2021). This approach provides an alternative solution for human-in-the-loop control.

Conclusions

The typical hip exoskeletons reported in the literature are summarized and listed in Table 1. They are classified through the framework of actuation joints (such as active/passive, rigid/flexible) and high-level control strategies (including the selection of sensors, gait recognition algorithms, and assistive torque generation algorithms) as mentioned above.

Table 1. Walking assist hip exoskeletons

Abbreviations: AO, adaptive oscillators; AOPO, Adaptive Oscillator & Phase Oscillator; APO, Active Pelvis Orthosis; AWS, Augmented Walking Suit; CNN, Convolutional neural network; EMG, Electromyogram; FHAE, Flexible Hip Assistive Exoskeleton; FSM, finite state machine; FSR, force-sensitive resistor; GEMS, Gait Enhancing Mechatronic System; HIL, Human In the Loop; IMU, inertial measurement unit; NREL, “Not provided in references”; PGM, pneumatic gel muscle; QDD, quasi-direct drive; SAS, Stride Assistance System; SEA, serial elastic actuators; SIAT, Shenzhen Institute of Advanced Technology; SSSUP, Scuola Superiore di Studi Universitari e di Perfezionamento Sant’Anna; SMA, Stride Management Assist system; TBE, time-based estimation; WEI, Wearable Xian Jiao Tong University exoskeleton; XPED2, Not provided in references Exoskeleton Instrument; XJTU, Xian Jiao Tong University exoskeleton.

The developments of walking assist hip exoskeleton, especially focusing on the framework of actuation joint and high-level control strategy, have been demonstrated in this review. The active hip exoskeleton joints are mostly driven by a motor with gear reducer, motor with Bowden cable, pneumatic actuator, and SEA, while the passive hip exoskeleton restores and releases the energy of the human body during certain gait phases through the elastic elements. A high-level control strategy mainly consists of three steps: data collection, Gait Phase Estimation, and assist torque generation. For data collection, one part of data sensing is for gait phase estimation, such as physical signals including ground reaction forces, joint angles, and human–machine interaction forces. While another part is for assist torque generation, such as physiological signals including sEMG and metabolic cost. Gait phase estimation consists of discrete gait event classification and continuous gait phase estimation. The latter one is more promising for the walking-assist hip exoskeleton since it contains more information. Assist torque can be either predefined offline referring to the biomechanical database or tuned online based on the states of the human, robot, or both.

For intuitive understanding, each part of the high-level control strategy for related hip exoskeleton prototypes is summarized in Figure 8. Each colored square stands for use of corresponding sensors, gait phase recognition methods, and assist torque generation methods as listed at the top of each column. The same color in the squares for each row stands for the hip exoskeleton prototypes from the same research group. IMU and FSR are mostly used by each hip exoskeleton prototype for gait phase estimation and the encoder is mainly mounted into an actuator modular to realize high-performance low-level position or torque control. The major researchers select AO for continuous gait phase estimation for its outstanding performance of gait phase estimation accuracy and gait trajectory prediction which is applicable for both periodic and quasi-periodic gaits. Besides, various simple and efficient parameters-based torque generation algorithms can be adopted with gait phase and predicted gait trajectory obtained from AO. Although database and function-based torque generation algorithms seem more popular at the moment, human-in-the-loop optimization is more promising for torque generation since it directly optimizes the desired evaluation indicators such as muscle activation and metabolic cost.

Figure 8. Detailed comparison of robotic hip exoskeletons from the aspect of data-collection, gait phase estimation, and assist torque generation. The same color in the squares for each row stands for the hip exoskeleton prototypes from the same research group.

This review presents the design and control of the hip exoskeleton for walking assist. Although remarkable breakthroughs have been made, some technical barriers still need to be overcome. The future R&D direction should be (but not limited to): (a) development of soft actuators with large torque density and high torque tracking control bandwidth; (b) integrated design of the untethered and portable system with high computational power and the weight is designed to be as light as possible; and (c) modeling of multiple scenarios recognition algorithms and accurate gait phase estimation/switch algorithms for the unstructured environment. We believe that wearable robotics technology will benefit humans and become an indispensable external organ for a better life once the aforementioned technology barriers are overcome and human–machine integration is realized.

Funding Statement

This work was supported by Natural Science Foundation of Zhejiang Province (Grant number LY21E050020), and by Ningbo Science and Technology Innovation 2025 Project (Grant number 2020Z022, 2020Z082, and 2021Z108).

Competing Interests

The authors declare no competing interests exist.

Authorship Contributions

Conceptualization: C.Y., W.Y.; Data curation: L.Y., L.X., Z.Y., D.H.; Data visualization: L.Y., W.Y.; Manuscript writing: C.Y., S.Z., W.Y. All authors approved the final submitted draft.

References

Asbeck, AT, Schmidt, K, Galiana, I, Wagner, D and Walsh, CJ (2015) Multi-joint soft exosuit for gait assistance. In 2015 IEEE International Conference on Robotics and Automation (ICRA). Seattle, USA: IEEE, pp. 61976204.CrossRefGoogle Scholar
Baud, R, Manzoori, AR, Ijspeert, A and Bouri, M (2021) Review of control strategies for lower-limb exoskeletons to assist gait. Journal of Neuroengineering and Rehabilitation 18(1), 119.CrossRefGoogle ScholarPubMed
Beneke, R and Meyer, K (1997) Walking performance and economy in chronic heart failure patients pre and post exercise training. European Journal of Applied Physiology and Occupational Physiology 75(3), 246251.CrossRefGoogle ScholarPubMed
Bryan, GM, Franks, PW, Klein, SC, Peuchen, RJ and Collins, SH (2021) A hip–knee–ankle exoskeleton emulator for studying gait assistance. The International Journal of Robotics Research 40(4–5), 722746.CrossRefGoogle Scholar
Buchli, J, Ijspeert, AJ, Schaal, S, Billard, A, Vijayakumar, S, Hallam, J and Meyer, J-A (2004) A simple, adaptive locomotion toy-system. A simple, adaptive locomotion toy-system. In From Animals to Animats. Cambridge, MA: MIT Press.Google Scholar
Buesing, C, Fisch, G, O’Donnell, M, Shahidi, I, Thomas, L, Mummidisetty, CK, Williams, KJ, Takahashi, H, Rymer, WZ and Jayaraman, A (2015) Effects of a wearable exoskeleton stride management assist system (SMA®) on spatiotemporal gait characteristics in individuals after stroke: A randomized controlled trial. Journal of Neuroengineering and Rehabilitation 12(1), 69.CrossRefGoogle ScholarPubMed
Camargo, J, Ramanathan, A, Flanagan, W and Young, A (2021) A comprehensive, open-source dataset of lower limb biomechanics in multiple conditions of stairs, ramps, and level-ground ambulation and transitions. Journal of Biomechanics 119, 110320.CrossRefGoogle ScholarPubMed
Carberry, J, Hinchly, G, Buckerfield, J, Tayler, E, Burton, T, Madgwick, S and Vaidyanathan, R (2011) Parametric design of an active ankle foot orthosis with passive compliance. In 2011 24th International Symposium on Computer-Based Medical Systems (CBMS). Bristol: IEEE, pp. 16.Google Scholar
Chang, SE, Pesek, T, Pote, TR, Hull, J, Geissinger, J, Simon, AA, Alemi, MM and Asbeck, AT (2020) Design and preliminary evaluation of a flexible exoskeleton to assist with lifting. Wearable Technologies 1, E10.CrossRefGoogle Scholar
Chen, T, Casas, R and Lum, PS (2019) An elbow exoskeleton for upper limb rehabilitation with series elastic actuator and cable-driven differential. IEEE Transactions on Robotics 35(6), 14641474.CrossRefGoogle ScholarPubMed
Chen, Q, Guo, S, Sun, L, Liu, Q and Jin, S (2021) Inertial measurement unit-based optimization control of a soft exosuit for hip extension and flexion assistance. Journal of Mechanisms and Robotics 13(2), 021016.CrossRefGoogle Scholar
Chen, W, Wu, S, Zhou, T and Xiong, C (2019) On the biological mechanics and energetics of the hip joint muscle-tendon system assisted by passive hip exoskeleton. Bioinspiration & Biomimetics 14(1), 016012.CrossRefGoogle Scholar
Chen, C, Zhang, Y, Li, Y, Wang, Z, Liu, Y, Cao, W and Wu, X (2020) Iterative learning control for a soft exoskeleton with hip and knee joint assistance. Sensors 20(15), 4333.CrossRefGoogle ScholarPubMed
Chen, B, Zi, B, Qin, L and Pan, Q (2020) State-of-the-art research in robotic hip exoskeletons: A general review. Journal of Orthopaedic Translation 20, 413.CrossRefGoogle ScholarPubMed
Chiu, VL, Raitor, M and Collins, SH (2021) Design of a hip exoskeleton with actuation in frontal and sagittal planes. IEEE Transactions on Medical Robotics and Bionics 3(3), 773782.CrossRefGoogle Scholar
Collins, S, Wiggin, M and Sawicki, G (2015) Reducing the energy cost of human walking using an unpowered exoskeleton. Nature 522, 212215.CrossRefGoogle ScholarPubMed
Crea, S, Manca, S, Parri, A, Zheng, E, Mai, J, Lova, RM, Vitiello, N and Wang, Q (2019) Controlling a robotic hip exoskeleton with noncontact capacitive sensors. IEEE/ASME Transactions on Mechatronics 24(5), 22272235.CrossRefGoogle Scholar
De La Fuente, J, Subramanian, SC, Sugar, TG and Redkar, S (2020) A robust phase oscillator design for wearable robotic systems. Robotics and Autonomous Systems 128, 103514.CrossRefGoogle Scholar
De la Fuente, J, Sugar, TG and Redkar, S (2017) Nonlinear, phase-based oscillator to generate and assist periodic motions. Journal of Mechanisms and Robotics 9(2), 024502.CrossRefGoogle Scholar
Ding, Y, Galiana, I, Siviy, C, Panizzolo, F A and Walsh, C (2016) IMU-based iterative control for hip extension assistance with a soft exosuit. In 2016 IEEE International Conference on Robotics and Automation (ICRA). Stockholm, Sweden: IEEE, pp. 35013508.CrossRefGoogle Scholar
Ding, Y, Kim, Myunghee, Kuindersma, S and Walsh, C (2018) Human-in-the-loop optimization of hip assistance with a soft exosuit during walking. Science Robotics 3, eaar5438.CrossRefGoogle ScholarPubMed
Ding, Y, Panizzolo, FA, Siviy, C, Malcolm, P, Galiana, I, Holt, KG and Walsh, CJ (2016) Effect of timing of hip extension assistance during loaded walking with a soft exosuit. Journal of Neuroengineering and Rehabilitation 13(1), 87.CrossRefGoogle ScholarPubMed
Fang, T, Cao, W, Chen, C, Zhang, Y, Wang, Z and Wu, X (2021) A soft exosuit for hip extension assistance of the elderly. Technology and Health Care 29(4), 837841.CrossRefGoogle ScholarPubMed
Farris, RJ, Quintero, HA, Murray, SA, Ha, KH, Hartigan, C and Goldfarb, M (2014) A preliminary assessment of legged mobility provided by a lower limb exoskeleton for persons with paraplegia. IEEE Transactions on Neural Systems and Rehabilitation Engineering 22(3), 482490.CrossRefGoogle ScholarPubMed
Felt, W, Selinger, J, Donelan, M and Remy, C (2015) “Body-in-the-loop”: Optimizing device parameters using measures of instantaneous energetic cost. PLoS One 10, e0135342.CrossRefGoogle ScholarPubMed
Ferris, DP and Lewis, CL (2009) Robotic lower limb exoskeletons using proportional myoelectric control. In 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Minneapolis, MN: IEEE, pp. 21192124.CrossRefGoogle Scholar
Franks, PW, Bryan, GM, Martin, RM, Reyes, R, Lakmazaheri, AC and Collins, SH (2021) Comparing optimized exoskeleton assistance of the hip, knee, and ankle in single and multi-joint configurations. Wearable Technologies 2, E16.CrossRefGoogle Scholar
Galle, S, Malcolm, P, Collins, SH and De Clercq, D (2017) Reducing the metabolic cost of walking with an ankle exoskeleton: Interaction between actuation timing and power. Journal of Neuroengineering and Rehabilitation 14(1), 35.CrossRefGoogle Scholar
Gams, A, Ijspeert, AJ, Schaal, S and Lenarcic, J (2009) On-line learning and modulation of periodic movements with nonlinear dynamical systems. Autonomous Robots 27, 323.CrossRefGoogle Scholar
Gandolla, M, Dalla Gasperina, S, Longatelli, V, Manti, A, Aquilante, L, D’Angelo, MG, Biffi, E, Diella, E, Molteni, F, Rossini, M, Gfohler, M, Puchinger, M, Bocciolone, M, Braghin, F and Pedrocchi, A (2021) An assistive upper-limb exoskeleton controlled by multi-modal interfaces for severely impaired patients: Development and experimental assessment. Robotics and Autonomous Systems 143, 103822.CrossRefGoogle Scholar
Giovacchini, F, Vannetti, F, Fantozzi, M, Cempini, M, Cortese, M, Parri, A, Yan, T, Lefeber, D and Vitiello, N (2015) A light-weight active orthosis for hip movement assistance. Robotics and Autonomous Systems 73, 123134.CrossRefGoogle Scholar
Grazi, L, Crea, S, Parri, A, Lova, RM, Micera, S and Vitiello, N (2018) Gastrocnemius myoelectric control of a robotic hip exoskeleton can reduce the user’s lower-limb muscle activities at push off. Frontiers in Neuroscience 12, 71.CrossRefGoogle ScholarPubMed
Haufe, FL, Wolf, P, Riener, R and Grimmer, M (2020) Biomechanical effects of passive hip springs during walking. Journal of Biomechanics 98, 109432.CrossRefGoogle ScholarPubMed
He, H and Kiguchi, K. (2007) A study on EMG-based control of exoskeleton robots for human lower-limb motion assist. In 2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine. Tokyo: IEEE, pp. 292295.CrossRefGoogle Scholar
Hong, W, Anil Kumar, N and Hur, P (2021) A phase-shifting based human gait phase estimation for powered transfemoral prostheses. IEEE Robotics and Automation Letters 6(3), 51135120.CrossRefGoogle Scholar
Hong, MB, Kim, GT and Yoon, YH (2019) ACE-ankle: A novel sensorized RCM (remote-center-of-motion) ankle mechanism for military purpose exoskeleton. Robotica 37(12), 22092228.CrossRefGoogle Scholar
Hoogkamer, W, Kipp, S, Spiering, BA and Kram, R (2016) Altered running economy directly translates to altered distance-running performance. Medicine & Science in Sports & Exercise 48(11), 21752180.CrossRefGoogle ScholarPubMed
Hu, BH, Krausz, NE and Hargrove, LJ (2018) A novel method for bilateral gait segmentation using a single thigh-mounted depth sensor and IMU. In 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob). Enschede, Netherland: IEEE, pp. 807812.CrossRefGoogle Scholar
Hwang, SH, Sun, DI, Han, J and Wan-Soo, K (2021) Gait pattern generation algorithm for lower-extremity rehabilitation–exoskeleton robot considering wearer’s condition. Intelligent Service Robotics 14(3), 345355.CrossRefGoogle Scholar
Ikeuchi, Y (2007) Development of moment assist and system weight compensation control for wearable walking assist system. Honda R&D Technical Review 19(2), 154.Google Scholar
Iranzo, S, Piedrabuena, A, Iordanov, D, Martinez-Iranzo, U and Belda-Lois, J-M (2020) Ergonomics assessment of passive upper-limb exoskeletons in an automotive assembly plant. Applied Ergonomics 87, 103120.CrossRefGoogle Scholar
Ishmael, MK, Archangeli, D and Lenzi, T (2021) Powered hip exoskeleton improves walking economy in individuals with above-knee amputation. Nature Medicine 27(10), 17831788.CrossRefGoogle ScholarPubMed
Ishmael, MK, Archangeli, D and Lenzi, T (2022) A powered hip exoskeleton with high torque density for walking, running, and stair ascent. IEEE/ASME Transactions on Mechatronics, 112.CrossRefGoogle Scholar
Kang, I, Hsu, H and Young, AJ (2018) Design and validation of a torque controllable hip exoskeleton for walking assistance. In Proceedings of the Asme 11th Annual Dynamic Systems and Control Conference, Vol 1. New York: American Society of Mechanical Engineers, p. V001T12A002.Google Scholar
Kang, I, Hsu, H and Young, A (2019) The effect of hip assistance levels on human energetic cost using robotic hip exoskeletons. IEEE Robotics and Automation Letters 4(2), 430437.CrossRefGoogle Scholar
Kang, I, Molinaro, DD, Choi, G and Young, AJ (2020) Continuous locomotion mode classification using a robotic hip exoskeleton. In 2020 8th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (Biorob). New York: IEEE, pp. 376381.CrossRefGoogle Scholar
Kang, I, Molinaro, DD, Duggal, S, Chen, Y, Kunapuli, P and Young, AJ (2021) Real-time gait phase estimation for robotic hip exoskeleton control during multimodal locomotion. IEEE Robotics and Automation Letters 6(2), 34913497.CrossRefGoogle ScholarPubMed
Kawamura, T, Takanaka, K, Nakamura, T and Osumi, H (2013) Development of an orthosis for walking assistance using pneumatic artificial muscle: A quantitative assessment of the effect of assistance. In 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR). Seattle, USA: IEEE, pp. 16.Google Scholar
Kerestes, J, Sugar, TG, and Holgate, M (2015) Adding and subtracting energy to body motion: Phase oscillator. In ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. New York: American Society of Mechanical Engineers Digital Collection.Google Scholar
Kiguchi, K (2007) Active exoskeletons for upper-limb motion assist. International Journal of Humanoid Robotics 4(3), 607624.CrossRefGoogle Scholar
Kiguchi, K, Esaki, R and Fukuda, T (2005) Development of a wearable exoskeleton for daily forearm motion assist. Advanced Robotics 19(7), 751771.CrossRefGoogle Scholar
Kiguchi, K, Tanaka, T and Fukuda, T (2004) Neuro-fuzzy control of a robotic exoskeleton with EMG signals. IEEE Transactions on Fuzzy Systems 12, 481490.CrossRefGoogle Scholar
Kim, J, Lee, G, Heimgartner, R, Arumukhom Revi, D, Karavas, N, Nathanson, D, Galiana, I, Eckert-Erdheim, A, Murphy, P, Perry, D, Menard, N, Choe, DK, Malcolm, P and Walsh, CJ (2019) Reducing the metabolic rate of walking and running with a versatile, portable exosuit. Science 365(6454), 668672.CrossRefGoogle ScholarPubMed
Kong, K and Tomizuka, M (2009) A gait monitoring system based on air pressure sensors embedded in a shoe. IEEE/ASME Transactions on Mechatronics 14, 358370.CrossRefGoogle Scholar
Lazzaroni, M, Tabasi, A, Toxiri, S, Caldwell, DG, Momi, ED, van Dijk, W, de Looze, MP, Kingma, I, van Dieën, JH and Ortiz, J (2020) Evaluation of an acceleration-based assistive strategy to control a back-support exoskeleton for manual material handling. Wearable Technologies 1, E9.CrossRefGoogle Scholar
Lee, G, Ding, Y, Bujanda, IG, Karavas, N, Zhou, YM and Walsh, CJ (2017a) Improved assistive profile tracking of soft exosuits for walking and jogging with off-board actuation. In 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). Vancouver, Canada: IEEE, pp. 16991706.CrossRefGoogle Scholar
Lee, D, Kang, I, Molinaro, DD, Yu, A and Young, AJ (2021) Real-time user-independent slope prediction using deep learning for modulation of robotic knee exoskeleton assistance. IEEE Robotics and Automation Letters 6(2), 39954000.CrossRefGoogle Scholar
Lee, G, Kim, J, Panizzolo, FA, Zhou, YM, Baker, LM, Galiana, I, Malcolm, P and Walsh, CJ (2017b) Reducing the metabolic cost of running with a tethered soft exosuit. Science Robotics 2(6), eaan6708.CrossRefGoogle Scholar
Lee, HJ, Lee, S, Chang, WH, Seo, K, Shim, Y, Choi, BO, Ryu, GH and Kim, YH (2017c) A wearable hip assist robot can improve gait function and cardiopulmonary metabolic efficiency in elderly adults. IEEE Transactions on Neural Systems and Rehabilitation Engineering 25, 15491557.Google Scholar
Lee, HJ, Lee, SH, Seo, K, Lee, M, Chang, WH, Choi, BO, Ryu, GH and Kim, YH (2019) Training for walking efficiency with a wearable hip-assist robot in patients with stroke: A pilot randomized controlled trial. Stroke 50(12), 35453552.CrossRefGoogle ScholarPubMed
Lee, Y, Roh, S, Lee, M, Choi, B, Lee, J, Kim, J, Choi, H, Shim, Y and Kim, Y (2017d) A flexible exoskeleton for hip assistance. In 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). Vancouver, Canada: IEEE, pp. 10581063.CrossRefGoogle Scholar
Lenzi, T, Carrozza, MC and Agrawal, SK (2013) Powered hip exoskeletons can reduce the User’s hip and ankle muscle activations during walking. IEEE Transactions on Neural Systems and Rehabilitation Engineering 21(6), 938948.CrossRefGoogle ScholarPubMed
Lewis, CL and Ferris, DP (2011) Invariant hip moment pattern while walking with a robotic hip exoskeleton. Journal of Biomechanics 44(5), 789793.CrossRefGoogle ScholarPubMed
Li, B, Yuan, B, Tang, S, Mao, Y, Zhang, D, Huang, C and Tan, B (2018) Biomechanical design analysis and experiments evaluation of a passive knee-assisting exoskeleton for weight-climbing. Industrial Robot: An International Journal 45(4), 436445.CrossRefGoogle Scholar
Lim, B, Lee, J, Jang, J, Kim, K, Park, YJ, Seo, K and Shim, Y (2019) Delayed output feedback control for gait assistance with a robotic hip exoskeleton. IEEE Transactions on Robotics 35(4), 10551062.CrossRefGoogle Scholar
Lv, G, Zhu, H and Gregg, RD (2018) On the design and control of highly Backdrivable lower-limb exoskeletons: A discussion of past and ongoing work. IEEE Control Systems Magazine 38(6), 88113.CrossRefGoogle ScholarPubMed
Menguc, Y, Park, Y-L, Martinez-Villalpando, E, Aubin, P, Zisook, M, Stirling, L, Wood, R and Walsh, C (2013). Soft wearable motion sensing suit for lower limb biomechanics measurements. In Proceedings of the IEEE International Conference on Robotics and Automation. Karlsruhe,Germanyon: IEEE, pp. 53095316.Google Scholar
Nesler, C, Thomas, G, Divekar, N, Rouse, EJ and Gregg, RD (2022) Enhancing voluntary motion with modular, Backdrivable, powered hip and knee orthoses. IEEE Robotics and Automation Letters 7(3), 61556162.CrossRefGoogle Scholar
Nuckols, RW, Lee, S, Swaminathan, K, Orzel, D, Howe, RD and Walsh, CJ (2021) Individualization of exosuit assistance based on measured muscle dynamics during versatile walking. Science Robotics 6(60), eabj1362.CrossRefGoogle ScholarPubMed
Oh, S and Kong, K (2017) High-precision robust force control of a series elastic actuator. IEEE/ASME Transactions on Mechatronics 22(1), 7180.CrossRefGoogle Scholar
Panizzolo, FA, Freisinger, GM, Karavas, N, Eckert-Erdheim, AM, Siviy, C, Long, A, Zifchock, RA, LaFiandra, ME and Walsh, CJ (2019) Metabolic cost adaptations during training with a soft exosuit assisting the hip joint. Scientific Reports 9(1), 9779.CrossRefGoogle ScholarPubMed
Pappas, IPI, Keller, T, Mangold, S, Popovic, MR, Dietz, V and Morari, M (2004) A reliable gyroscope-based gait-phase detection sensor embedded in a shoe insole. IEEE Sensors Journal 4(2), 268274.CrossRefGoogle Scholar
Pappas, IPI, Popovic, MR, Keller, T, Dietz, V and Morari, M (2001) A reliable gait phase detection system. IEEE Transactions on Neural Systems and Rehabilitation Engineering 9(2), 113125.CrossRefGoogle ScholarPubMed
Park, Y-L, Chen, B, Pérez-Arancibia, NO, Young, D, Stirling, L, Wood, RJ, Goldfield, EC and Nagpal, R (2014) Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation. Bioinspiration & Biomimetics 9(1), 016007.CrossRefGoogle ScholarPubMed
Pratt, GA and Williamson, MM (1995) Series elastic actuators. In Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots. Pittsburgh, PA, USA: IEEE, Vol. 1, pp. 399406.CrossRefGoogle Scholar
Quinlivan, B, Lee, S, Malcolm, P, Rossi, D, Grimmer, M, Siviy, C, Karavas, N, Wagner, D, Asbeck, A, Galiana, I and Walsh, C (2017) Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit. Science Robotics 2, eaah4416.CrossRefGoogle ScholarPubMed
Ronsse, R, De Rossi, SMM, Vitiello, N, Lenzi, T, Koopman, B, van der Kooij, H, Carrozza, MC and Ijspeert, AJ (2012) Real-time estimate of period derivatives using adaptive oscillators: Application to impedance-based walking assistance. In 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems. Vilamoura, Algarve, Portugal: IEEE, pp. 33623368.CrossRefGoogle Scholar
Ronsse, R, Koopman, B, Vitiello, N, Lenzi, T, De Rossi, SMM, Kieboom, J, van Asseldonk, E, Carrozza, M, Kooij, H and Ijspeert, AJ (2011a) Oscillator-based walking assistance: A model-free approach. In Proceedings of the IEEE International Conference on Rehabilitation Robotics, 2011. Zurich, Switzerland: IEEE, p. 5975352.Google Scholar
Ronsse, R, Vitiello, N, Lenzi, T, van den Kieboom, J, Carrozza, MC and Ijspeert, AJ (2011b) Human–robot synchrony: Flexible assistance using adaptive oscillators. IEEE Transactions on Biomedical Engineering 58(4), 10011012.CrossRefGoogle Scholar
Sanz-Merodio, D, Cestari, M, Arevalo, JC, Carrillo, XA and Garcia, E (2014) Generation and control of adaptive gaits in lower-limb exoskeletons for motion assistance. Advanced Robotics 28(5), 329338.CrossRefGoogle Scholar
Sawicki, GS, Beck, ON, Kang, I and Young, AJ (2020) The exoskeleton expansion: Improving walking and running economy. Journal of Neuroengineering and Rehabilitation 17(1), 25.CrossRefGoogle ScholarPubMed
Sawicki, GS, Gordon, K and Ferris, D (2005). Powered lower limb orthoses: Applications in motor adaptation and rehabilitation. In 9th International Conference on Rehabilitation Robotics (ICORR), 2005. Chicago, USA: IEEE, pp. 206211.Google Scholar
Seo, K, Hyung, S, Choi, BK, Lee, Y and Shim, Y (2015) A new adaptive frequency oscillator for gait assistance. In 2015 IEEE International Conference on Robotics and Automation (ICRA). Seattle, USA: IEEE, pp. 55655571.Google Scholar
Seo, K, Kim, K, Park, YJ, Cho, JK, Lee, J, Choi, B, Lim, B, Lee, Y and Shim, Y (2018) Adaptive oscillator-based control for active lower-limb exoskeleton and its metabolic impact. In 2018 IEEE International Conference on Robotics and Automation (ICRA). Brisbane, Australia: IEEE, pp. 67526758.CrossRefGoogle Scholar
Seo, K, Lee, J, Lee, Y, Ha, T and Shim, Y (2016) Fully autonomous hip exoskeleton saves metabolic cost of walking. In 2016 IEEE International Conference on Robotics and Automation (ICRA). Stockholm, Sweden: IEEE, pp. 46284635.CrossRefGoogle Scholar
Seo, K, Park, YJ, Lee, J, Hyung, S, Lee, M, Kim, J, Choi, H and Shim, Y (2019) RNN-based on-line continuous gait phase estimation from shank-mounted IMUs to control ankle exoskeletons. In 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR). Montreal, Canada: IEEE, pp. 809815.CrossRefGoogle Scholar
Shafer, BA, Philius, SA, Nuckols, RW, McCall, J, Young, AJ and Sawicki, GS (2021) Neuromechanics and energetics of walking with an ankle exoskeleton using neuromuscular-model based control: A parameter study. Frontiers in Bioengineering and Biotechnology 9, 210.CrossRefGoogle ScholarPubMed
Shepertycky, M, Burton, S, Dickson, A, Liu, Y-F and Li, Q (2021) Removing energy with an exoskeleton reduces the metabolic cost of walking. Science 372(6545), 957960.CrossRefGoogle ScholarPubMed
Shimada, H, Hirata, T, Kimura, Y, Naka, T, Kikuchi, K, Oda, K, Ishii, K, Ishiwata, K and Suzuki, T (2009) Effects of a robotic walking exercise on walking performance in community-dwelling elderly adults. Geriatrics & Gerontology International 9(4), 372381.CrossRefGoogle ScholarPubMed
Shiraishi, M and Watanabe, H (1996) Pneumatic assist device for gait restoration. Journal of Dynamic Systems, Measurement, and Control 118(1), 914.CrossRefGoogle Scholar
Song, S and Collins, SH (2021) Optimizing exoskeleton assistance for faster self-selected walking. IEEE Transactions on Neural Systems and Rehabilitation Engineering 29, 786795.CrossRefGoogle ScholarPubMed
Sridar, S, Nguyen, PH, Zhu, M, Lam, QP and Polygerinos, P (2017) Development of a soft-inflatable exosuit for knee rehabilitation. In 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). Vancouver, Canada: IEEE, pp. 37223727.CrossRefGoogle Scholar
Sridar, S, Poddar, S, Tong, Y, Polygerinos, P and Zhang, W (2020) Towards untethered soft pneumatic exosuits using low-volume inflatable actuator composites and a portable pneumatic source. IEEE Robotics and Automation Letters 5(3), 40624069.CrossRefGoogle Scholar
Steijlen, A, Burgers, B, Wilmes, E, Bastemeijer, J, Bastiaansen, B, French, P, Bossche, A and Jansen, K (2021) Smart sensor tights: Movement tracking of the lower limbs in football. Wearable Technologies 2, 115.CrossRefGoogle Scholar
Sugar, TG, Bates, A, Holgate, M, Kerestes, J, Mignolet, M, New, P, Ramachandran, RK, Redkar, S and Wheeler, C (2015) Limit cycles to enhance human performance based on phase oscillators. Journal of Mechanisms and Robotics 7(1), 011001.CrossRefGoogle Scholar
Sugar, TG, Fernandez, E, Kinney, D, Hollander, KW and Redkar, S (2017) HeSA, hip exoskeleton for superior assistance. In González-Vargas, J, Ibáñez, J, Contreras-Vidal, JL, van der Kooij, H and Pons, JL (eds), Wearable Robotics: Challenges and Trends. Cham: Springer International Publishing, pp. 319323.CrossRefGoogle Scholar
Susanto, Riska A and Song, K-T (2016) Design of assistive torque for a lower limb exoskeleton based on motion prediction. In 2016 55th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE). Tsukuba, Japan: IEEE, pp. 172177.CrossRefGoogle Scholar
Thakur, C, Ogawa, K, Tsuji, T and Kurita, Y (2018) Soft wearable augmented walking suit with pneumatic gel muscles and stance phase detection system to assist gait. IEEE Robotics and Automation Letters 3(4), 42574264.CrossRefGoogle Scholar
Thalman, C and Artemiadis, P (2020) A review of soft wearable robots that provide active assistance: Trends, common actuation methods, fabrication, and applications. Wearable Technologies 1, e3.CrossRefGoogle Scholar
Tricomi, E, Lotti, N, Missiroli, F, Zhang, X, Xiloyannis, M, Müller, T, Crea, S, Papp, E, Krzywinski, J, Vitiello, N and Masia, L (2022) Underactuated soft hip exosuit based on adaptive oscillators to assist human locomotion. IEEE Robotics and Automation Letters 7(2), 936943.CrossRefGoogle Scholar
Tu, X, Li, M, Liu, M, Si, J, and Huang, HH (2021) A data-driven reinforcement learning solution framework for optimal and adaptive personalization of a hip exoskeleton. In 2021 IEEE International Conference on Robotics and Automation (ICRA). Xi’an, China: IEEE, pp. 1061010616.CrossRefGoogle Scholar
Tucker, MR, Olivier, J, Pagel, A, Bleuler, H, Bouri, M, Lambercy, O, Millán J del, R, Riener, R, Vallery, H and Gassert, R (2015) Control strategies for active lower extremity prosthetics and orthotics: A review. Journal of Neuroengineering and Rehabilitation 12(1), 1.CrossRefGoogle ScholarPubMed
Vallery, H, Veneman, J, van Asseldonk, E, Ekkelenkamp, R, Buss, M and van Der Kooij, H (2008) Compliant actuation of rehabilitation robots. IEEE Robotics Automation Magazine 15(3), 6069.CrossRefGoogle Scholar
van Dijk, W and Van der Kooij, H (2014) XPED2: A passive exoskeleton with artificial tendons. IEEE Robotics Automation Magazine 21(4), 5661.CrossRefGoogle Scholar
Veneman, JF, Ekkelenkamp, R, Kruidhof, R, van der Helm, FCT and van der Kooij, H (2005) Design of a series elastic- and Bowden cable-based actuation system for use as torque-actuator in exoskeleton-type training. In 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. Chicago, USA: IEEE, pp. 496499.CrossRefGoogle Scholar
Veneman, JF, Ekkelenkamp, R, Kruidhof, R, van der Helm, FCT and van der Kooij, H (2006) A series elastic- and Bowden-cable-based actuation system for use as torque actuator in exoskeleton-type robots. The International Journal of Robotics Research 25(3), 261281.CrossRefGoogle Scholar
Walsh, CJ, Pasch, K and Herr, H (2006) An autonomous, underactuated exoskeleton for load-carrying augmentation. In 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems. Beijing, China: IEEE, pp. 14101415.CrossRefGoogle Scholar
Wang, L, Wang, S, van Asseldonk, EHF, and van der Kooij, H (2013) Actively controlled lateral gait assistance in a lower limb exoskeleton. In 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems. Tokyo, Japan: IEEE, pp. 965970.CrossRefGoogle Scholar
Wang, H, Yang, C, Yang, W, Deng, M, Ma, Z and Wei, Q (2019) A rehabilitation gait for the balance of human and lower extremity exoskeleton system based on the transfer of gravity center. Industrial Robot-the International Journal of Robotics Research and Application 46(5), 608621.CrossRefGoogle Scholar
Weigand, F, Zeiss, J, Grimmer, M and Konigorski, U (2020) A novel approach for gait phase estimation for different locomotion modes using kinematic shank information. In IFAC Papers Online, Vol. 53. Amsterdam: Elsevier, pp. 86978703.Google Scholar
Witte, KA, Fiers, P, Sheets-Singer, AL and Collins, SH (2020) Improving the energy economy of human running with powered and unpowered ankle exoskeleton assistance. Science Robotics 5(40), eaay9108.CrossRefGoogle ScholarPubMed
Wu, X, Ma, Y, Yong, X, Wang, C, He, Y and Li, N (2019) Locomotion mode identification and gait phase estimation for exoskeletons during continuous multi-locomotion tasks. IEEE Transactions on Cognitive and Developmental Systems 13, 4556.CrossRefGoogle Scholar
Wu, Q, Wang, X, Du, F and Zhang, X (2015) Design and control of a powered hip exoskeleton for walking assistance. International Journal of Advanced Robotic Systems 12, 18.CrossRefGoogle Scholar
Xu, L, Chen, J, Wang, F, Chen, Y, Yang, W and Yang, C (2021) Machine-learning-based children’s pathological gait classification with low-cost gait-recognition system. Biomedical Engineering Online 20(1), 62.CrossRefGoogle ScholarPubMed
Xue, T, Wang, Z, Zhang, T and Zhang, M (2019) Adaptive oscillator-based robust control for flexible hip assistive exoskeleton. IEEE Robotics and Automation Letters 4(4), 33183323.CrossRefGoogle Scholar
Yan, T, Parri, A, Ruiz Garate, V, Cempini, M, Ronsse, R and Vitiello, N (2017) An oscillator-based smooth real-time estimate of gait phase for wearable robotics. Autonomous Robots 41(3), 759774.CrossRefGoogle Scholar
Yan, H and Yang, C (2014) Optimal design on shoulder joint of upper limb exoskeleton robot for motor rehabilitation and system application. Journal of ZheJiang University (Engineering Science) 48(1), 10861094Google Scholar
Yang, W, Xu, L, Yu, L, Chen, Y, Yan, Z and Yang, C (2021) Hybrid oscillator-based no-delay hip exoskeleton control for free walking assistance. Industrial Robot: The International Journal of Robotics Research and Application 48(6), 906914.CrossRefGoogle Scholar
Yang, W, Yang, C and Xu, T (2016) Human hip joint center analysis for biomechanical design of a hip joint exoskeleton. Frontiers of Information Technology & Electronic Engineering 17(8), 792802.CrossRefGoogle Scholar
Yang, W, Zhang, J, Zhang, S and Yang, C (2020) Lower limb exoskeleton gait planning based on crutch and human-machine foot combined Center of Pressure. Sensors (Basel, Switzerland) 20(24), 7216.CrossRefGoogle ScholarPubMed
Yasuhara, K, Ido, T, Shimada, K, Kikuchi, K, Koyama, T and Endo, Y (2009) Walking assist device with stride management system. Honda R&D Technical Review. 21, 5462.Google Scholar
Young, AJ, Foss, J, Gannon, H and Ferris, DP (2017a) Influence of power delivery timing on the energetics and biomechanics of humans wearing a hip exoskeleton. Frontiers in Bioengineering and Biotechnology 5, 4.CrossRefGoogle Scholar
Young, AJ, Gannon, H and Ferris, DP (2017b) A biomechanical comparison of proportional electromyography control to biological torque control using a powered hip exoskeleton. Frontiers in Bioengineering and Biotechnology 5, 37.CrossRefGoogle Scholar
Yu, S, Huang, T-H, Wang, D, Lynn, B, Sayd, D, Silivanov, V, Park, YS, Tian, Y and Su, H (2019) Design and control of a high-torque and highly Backdrivable hybrid soft exoskeleton for knee injury prevention during squatting. IEEE Robotics and Automation Letters 4(4), 45794586.CrossRefGoogle Scholar
Yu, S, Huang, T-H, Yang, X, Jiao, C, Yang, J, Chen, Y, Yi, J and Su, H (2020) Quasi-direct drive actuation for a lightweight hip exoskeleton with high Backdrivability and high bandwidth. IEEE/ASME Transactions on Mechatronics 25(4), 17941802.CrossRefGoogle ScholarPubMed
Zelik, KE, Huang T-W, P, Adamczyk, PG and Kuo, AD (2014) The role of series ankle elasticity in bipedal walking. Journal of Theoretical Biology 346, 7585.CrossRefGoogle ScholarPubMed
Zhang, J, Cheah, CC and Collins, SH (2015) Experimental comparison of torque control methods on an ankle exoskeleton during human walking. In 2015 IEEE International Conference on Robotics and Automation (ICRA). Seattle, USA: IEEE, pp. 55845589.CrossRefGoogle Scholar
Zhang, J and Collins, SH (2021) The iterative learning gain that optimizes real-time torque tracking for ankle exoskeletons in human walking under gait variations. Frontiers in Neurorobotics 15, 653409.CrossRefGoogle ScholarPubMed
Zhang, T, Feng, K, Zeng, B and Gong, Z (2021) Design and validation of a lightweight soft hip exosuit with series-wedge-structures for assistive walking and running. In IEEE/ASME Transactions on Mechatronics. IEEE, pp. 112.Google Scholar
Zhang, J, Fiers, P, Witte, KA, Jackson, RW, Poggensee, KL, Atkeson, CG and Collins, SH (2017) Human-in-the-loop optimization of exoskeleton assistance during walking. Science 356(6344), 12801284.CrossRefGoogle ScholarPubMed
Zhang, T, Tran, M and Huang, H (2017) NREL-Exo: A 4-DoFs wearable hip exoskeleton for walking and balance assistance in locomotion. In Bicchi, A and Okamura, A (eds), 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (Iros). New York: IEEE, pp. 508513).CrossRefGoogle Scholar
Zhang, T, Tran, M and Huang, H (2019a) Admittance shaping-based assistive control of SEA-driven robotic hip exoskeleton. IEEE/ASME Transactions on Mechatronics 24(4), 15081519.CrossRefGoogle Scholar
Zhang, B, Wang, S, Zhou, M and Xu, W (2021) An adaptive framework of real-time continuous gait phase variable estimation for lower-limb wearable robots. Robotics and Autonomous Systems 143, 103842.CrossRefGoogle Scholar
Zhang, T and Xia, J (2019b) Development of a Clutchable series elastic actuator for robotic hip exoskeleton. In 2019 IEEE International Conference on Cybernetics and Intelligent Systems (CIS) and IEEE Conference on Robotics, Automation and Mechatronics (RAM). Bangkok, Thailand: IEEE, pp. 269274.CrossRefGoogle Scholar
Zheng, E, Manca, S, Yan, T, Parri, A, Vitiello, N and Wang, Q (2017) Gait phase estimation based on noncontact capacitive sensing and adaptive oscillators. IEEE Transactions on Biomedical Engineering 64(10), 24192430.CrossRefGoogle ScholarPubMed
Zheng, E and Wang, Q (2017) Noncontact capacitive sensing-based locomotion transition recognition for amputees with robotic Transtibial prostheses. IEEE Transactions on Neural Systems and Rehabilitation Engineering 25(2), 161170.CrossRefGoogle ScholarPubMed
Zheng, E, Wang, L, Wei, K and Wang, Q (2014) A noncontact capacitive sensing system for recognizing locomotion modes of Transtibial amputees. IEEE Transactions on Biomedical Engineering 61(12), 29112920.CrossRefGoogle ScholarPubMed
Zhou, T, Xiong, C, Zhang, J, Chen, W and Huang, X (2021b) Regulating metabolic energy among joints during human walking using a multiarticular unpowered exoskeleton. IEEE Transactions on Neural Systems and Rehabilitation Engineering 29, 662672.CrossRefGoogle Scholar
Zhou, T, Xiong, C, Zhang, J, Hu, D, Chen, W and Huang, X (2021a) Reducing the metabolic energy of walking and running using an unpowered hip exoskeleton. Journal of Neuroengineering and Rehabilitation 18(1), 95.CrossRefGoogle Scholar
Zhu, F, Kern, M, Fowkes, E, Afzal, T, Contreras-Vidal, J-L, Francisco, GE and Chang, S-H (2021) Effects of an exoskeleton-assisted gait training on post-stroke lower-limb muscle coordination. Journal of Neural Engineering 18(4), 046039.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. Frame of this review. AO, adaptive oscillator; Electromyogram (EMG), electromyogram, FSM, finite state machine; HIL, human-in-the-loop optimization; IMU, inertial measurement unit; NN, neuro network-based gait phase estimation; PO, phase oscillator; SEA, series elastic actuator; TBE, time-based estimation.

Figure 1

Figure 2. Hip exoskeleton with different actuators. (a) Motor with gear reducer (Shimada et al., 2009; Yasuhara et al., 2009; Buesing et al., 2015; Yang et al., 2021). (b) SEA (Giovacchini et al., 2015; Kang et al., 2018; Zhang et al., 2019a). (c) Pneumatic actuator (Young et al., 2017b; Thakur et al., 2018). (d) Motor with Bowden cable (Kim et al., 2019; Tricomi et al., 2022). (e) Passive (Zhou et al., 2021a,b).

Figure 2

Figure 3. Robotic hip exoskeleton with the index of metabolic cost reduction and selection of muscles for sEMG detection. BF, biceps femoris; GM, gluteus maximus; RF, rectus femoris; ST, semitendinosus; SOL, soleus; TA, tibialis anterior; VL, vastus lateralis; VM, vastus medialis.

Figure 3

Figure 4. Gait phase division during walking, which can be divided into discrete one and continuous one. DLS, double leg support; LHR, left heel rise; LHS, left heel strike; LLS, left leg support; LTO, left toe-off; RHR, right heel rise; RHS, right heel strike; RLS, right leg support; RTO, right toe-off.

Figure 4

Figure 5. Graphical diagrams of five gait estimation methods. (a) Finite state machine (Walsh et al., 2006), (b) Adaptive oscillator (Lenzi et al., 2013), (c) Phase oscillator (Sugar et al., 2015), (d) Neural network (Kang et al., 2021), and (e) Time-based estimation (Kang et al., 2018).

Figure 5

Figure 6. Typical assist torque generation methods. (a) Database with a look-up table (Xue et al., 2019). (b) Function-based on gait phase and assist torque factor (Yang et al., 2021). (c,d) Human-in-the-loop optimization (Ding et al., 2018; Chiu et al., 2021).

Figure 6

Figure 7. Diagrams for various assist torque generation algorithms. (a) Database (Seo et al., 2016). (b,c) Function with adjustable parameters (Lim et al., 2019; Yang et al., 2021). (d) Human-in-the-loop optimization (Zhang et al., 2017).

Figure 7

Table 1. Walking assist hip exoskeletons

Figure 8

Figure 8. Detailed comparison of robotic hip exoskeletons from the aspect of data-collection, gait phase estimation, and assist torque generation. The same color in the squares for each row stands for the hip exoskeleton prototypes from the same research group.