Hostname: page-component-cd9895bd7-dzt6s Total loading time: 0 Render date: 2024-12-26T21:18:37.630Z Has data issue: false hasContentIssue false

Application of the sensible heat balance to determine the temperature tolerance of commercial poultry housing

Published online by Cambridge University Press:  08 February 2008

M.A. GARCIMARTÍN
Affiliation:
Departamento de Construcción y Vías Rurales, E.T.S.I. Agrónomos, Universidad Politécnica de Madrid, Avda. Complutense s/n, 28040 Madrid, Spain
I. OVEJERO
Affiliation:
Departamento de Producción Animal, E.T.S.I. Agrónomos, Universidad Politécnica de Madrid, Avda. Complutense s/n, 28040 Madrid, Spain
E. SÁNCHEZ
Affiliation:
Departamento de Construcción y Vías Rurales, E.T.S.I. Agrónomos, Universidad Politécnica de Madrid, Avda. Complutense s/n, 28040 Madrid, Spain
V. SÁNCHEZ-GIRÓN*
Affiliation:
Departamento de Ingeniería Rural, E.T.S.I. Agrónomos, Universidad Politécnica de Madrid, Avda. Complutense s/n, 28040, Madrid, Spain
*
*Corresponding author: victor.sanchezgiron@upm.es
Get access

Abstract

A well-designed environmental control system is the most efficient tool to ensure optimal production in livestock housing. In countries having a hot climate, such as Spain, the former comprises a large proportion of the capital invested in housing, and it deserves a thorough assessment. Most of the research carried out has been done in countries with a temperate climate and considering short hot periods, or even without them. The efficiency of the evaporative cooling system, which is commonly used in hot climate areas, depends upon the pad wetted surface area exposed to the passing air. Keeping the chosen inside temperature requires a definite cooled down of the outdoor air that is related to the ‘temperature tolerance’, i.e. the difference between inside and incoming air temperatures. The objective of this work was to establish the temperature tolerance when using the steady-state heat balance in commercial poultry housing. The heat balance estimates were imbalanced whenever the difference between indoor and outdoor temperature was less than 2°C. Substituting the exhaust air temperature for the indoor temperature in the expression that provides the heat drawn out through ventilation balanced the heat equation. The difference between inside and incoming air temperatures, temperature tolerance, has to be at least 2°C.

Type
Research Article
Copyright
Copyright © World's Poultry Science Association 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

ALBRIGHT, L.D. (1990) Environment Control for Animals and Plants. ASAE, St Joseph, Michigan.Google Scholar
ASAE STANDARD (2001) EP270.5 DEC01. Design of Ventilation System for Poultry and Livestock Shelters, ASAE, St Joseph, Michigan.Google Scholar
CIGR (2002) Climatization of Animal Houses. 4th Report of Working Group. Heat and moisture production at animal and house levels. Danish Institute of Animal Science.Google Scholar
CIGR (1984) Climatization of animal houses. Report of Working Group, Scottish Farm Building Investigation Unit, Craibstone, Aberdeen, Scotland, UK.Google Scholar
COOPER, K., PARSONS, D.J. and DEMMERS, T. (1998) A thermal balance model for livestock buildings for use in climate change studies. Journal of Agricultural Engineering Research 69: 4352.CrossRefGoogle Scholar
DEMRATI, H., BOULARD, T, BEKKAOUI, A. and BOUIRDEN, L. (2001) Natural ventilation and microclimatic performance of a large-scale banana greenhouse. Journal of Agricultural Engineering Research 80: 261271.CrossRefGoogle Scholar
HAMRITA, T.K. and MITCHELL, B. (1999) Poultry environment and production control and optimization. A summary of where we are and where we want to go. Trans. of ASAE 42: 479483.CrossRefGoogle Scholar
LINDLEY, J.A. and WHITAKER, J.H. (1996) Agricultural buildings and structures. ASAE, St. Joseph, Michigan.Google Scholar
MITCHELL, B.W. (1993) Process control system for poultry house environment. Trans. of the ASAE 36: 18811886.CrossRefGoogle Scholar
PEDERSEN, S. (2005) Climatization of animal houses. A biographical review of three decades of research. Danish Institute of Animal Science. Report Livestock No. 66.Google Scholar
PEDERSEN, S., TAKAI, H., JOHNSEN, J.O., METZ, J.H.M., GROOT KOERKAMP, W.G., UENK, J.H., PHILIPS, V.R., HOLDEN, M.R., SNEATH, R.W., SHORT, J.L., WHITE, R.P., HARTUNG, J., SEEDORF, J., SCHRÖDER, M., LINKERT, K.H. and WATHES, CM. (1998) A comparison of three balance methods for calculating ventilation rates in livestock buildings. Journal of Agricultural Engineering Research 70: 2537.CrossRefGoogle Scholar
SCHAUBERGER, G, PIRINGER, M. and PETZ, E. (2000) Steady-state balance model to calculate the indoor climate of livestock buildings demonstrated for finishing pigs. International Journal of Biometeorology 43: 154162.CrossRefGoogle ScholarPubMed
SCHAUBERGER, G. (2000) Dynamic model of the indoor climate inside livestock buildings: A case study for fattening pigs. Swine Housing Procedures: First International Conference. Des-Moines, Iowa. pp. 340347.CrossRefGoogle Scholar
SPANISH STANDARD NBE-CT-79 (1989) Norma Básica de la Edificación. Condiciones Térmicas en los edificios. Mnisterio de Obras Públicas y Urbanismo, Madrid.Google Scholar
SPANISH STANDARD NTE-ICI-84 (1984) Norma Tecnológica de la Edificación. Instalaciones de climatización Individuales. Ministerio de Obras Públicas y Urbanismo, Madrid.Google Scholar