6 - Controlled bridge rectifiers with d.c. motor load

Published online by Cambridge University Press:  05 June 2012

W. Shepherd
Affiliation:
University of Bradford
L. N. Hulley
Affiliation:
University of Bradford
D. T. W. Liang
Affiliation:
University of Bradford
Get access

Summary

THE PRINCIPLES OF RECTIFICATION

The process of electrical rectification is where current from an a.c. supply is converted to a unidirectional form before being supplied to a load. Although unidirectional, the load current may pulsate in amplitude, depending on the load impedance. With resistive loads the load voltage polarity is fixed. The polarity of the voltage across series-connected load inductance elements may vary during the load current cycle.

In a rectifier circuit there are certain electrical properties that are of interest irrespective of circuit topology and impedance nature. These properties can be divided into two groups, (i) on the supply side, and (ii) on the load side of the rectifier, respectively. When the electrical supply system has a low (ideally zero) impedance, the sinusoidal supply voltages remain largely undistorted even when the rectifier action causes nonsinusoidal pulses of current to be drawn from the supply. For the purposes of circuit analysis one can assume that semiconductor rectifier elements, such as diodes and thyristor devices, are ideal in that they are dissipationless and have zero conducting voltage drop.

A study of rectifier circuits is basically a study of waveforms. No energy is stored within a rectifier so that there is a constant connection between the currents and voltages on the a.c. side and the current and voltage on the d.c. side. In rectifier calculations the essential requirement is to obtain an accurate physical picture of the operation and then establish circuit equations that are valid for the particular condition.

Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×