Chapter 4 - Nursing Considerations in Neuromonitoring

from Part I - General Considerations in Neuromonitoring

Published online by Cambridge University Press:  08 September 2022

Cecil D. Hahn
Affiliation:
The Hospital for Sick Children, University of Toronto
Courtney J. Wusthoff
Affiliation:
Lucile Packard Children’s Hospital, Stanford University
Get access

Summary

Neuromonitoring is a shared responsibility in the ICU with several key roles for bedside nursing staff, including the identification and reporting of trends. Nursing staff should be familiar with equipment and supplies needed for neuromonitoring as well as troubleshooting common artifacts and problems. Guideline development and ongoing education are essential to the success of any neuromonitoring program. This chapter provides suggested pathways for integrating bedside neuromonitoring into clinical practice and discussion of day-to-day nursing roles and responsibilities related to bedside monitoring. Multiple modalities, including EEG, aEEG, QEEG, and NIRS, are discussed.

Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 2022

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Shellhaas, RA, Chang, T, Tsuchida, T, et al. The American Clinical Neurophysiology Society’s guideline on continuous electroencephalography monitoring in neonates. J Clin Neurophysiol. 2011;28:611–17.CrossRefGoogle ScholarPubMed
Foreman, SW, Thorngate, L. Amplitude-integrated electroencephalography: a new approach to enhancing neurologic nursing care in the neonatal intensive care unit. NAINR. 2011;11:134140.Google Scholar
Zoet-Lavooi, J, van Rooij, LGM, Brouwer, AJ, Lemmers, P, de Vries, LS. Neuromonitoring: how to train your nursing staff. Paper presented at the 5th Congress of the European Academy of Paediatric EAPS 17–21, Barcelona, Spain, October 2014.Google Scholar
McCoy, B, Hahn, CD. Continuous EEG monitoring in the neonatal intensive care unit. J Clin Neurophysiol. 2013;30:106–14.CrossRefGoogle ScholarPubMed
Shah, NA, Wusthoff, CJ. How to use: amplitude integrated EEG (aEEG). Arch Dis Child Educ Pract Ed. 2015;100:7581.CrossRefGoogle ScholarPubMed
Hellstrom-Westas, L. The electrocortical background, its normal maturation, classification, and effects of medication. In de Vries, LS, Rosen, I, Hellstrom-Westas, L, editors. Atlas of Amplitude-Integrated EEGs in the Newborn, 2nd ed. London: Informa Healthcare; 2008, pp. 1742.Google Scholar
Pensirikul, AD, Beslow, LA, Kessler, SK, et al. Density spectral array for seizure identification in critically ill children. J Clin Neurophysiol. 2013;30:371–5.Google Scholar
Marin, T, Moore, J. Understanding near-infrared spectroscopy. Adv Neo Care. 2011;11:382–88.Google ScholarPubMed
Bernal, NP, Hoffman, GM, Ghanayem, NS, Arca, MJ. Cerebral and somatic near-infrared spectroscopy in normal newborns. J Pediatr Surg. 2010;45:1306–10.CrossRefGoogle ScholarPubMed
McNeill, S, Gatenby, JC, McElroy, S, Engelhardt, B. Normal cerebral, renal and abdominal regional oxygen saturations using near-infrared spectroscopy in preterm infants. J Perinatol. 2011;31:51–7.CrossRefGoogle ScholarPubMed
Toet, MC, Lemmers, PM. Brain monitoring in neonates. Early Hum Dev. 2009;85:7784.CrossRefGoogle ScholarPubMed
Whitelaw, A, White, RD. Training neonatal staff in recording and reporting continuous electroencephalography. Clin Perinatol. 2006;33:667–77.CrossRefGoogle ScholarPubMed
Chock, VY, Davis, AS. Bedside cerebral monitoring to predict neurodevelopmental outcomes. NeoReviews. 2009;10, e121e129.Google Scholar
McNeill, S, Gatenby, JC, McElroy, S, Engelhardt, B. Normal cerebral, renal and abdominal regional oxygen saturations using near-infrared spectroscopy in preterm infants. J Perinatol. 2011;31:51–7.CrossRefGoogle ScholarPubMed
Glass, HC, Wusthoff, CJ, Shellhaas, RA. Amplitude-integrated electro-encephalography: the child neurologist’s perspective. J Child Neurol. 2013;28:1342–50.CrossRefGoogle ScholarPubMed
Glass, HC, Bonifacio, SL, Peloquin, S, et al. Neurocritical care for neonates. Neurocrit Care. 2010;12:421–9.CrossRefGoogle ScholarPubMed
Duke University, QI Department, School of Medicine. Patient Safety Education. 2016. http://patientsafetyed.duhs.duke.edu/module_a/introduction/contrasting_qi_qa.htmlGoogle Scholar

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×